5-aderige kabel
ZC-YJV22 5 kernkabel 3x185mm2 + 2x95mm2 gepantserde XLPE vlamvertragende kabel 0.6/1kV
ZC-YJV22 5 Core 3x185mm²+2x95mm² Armored XLPE Flame Retardant Copper Cable 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Category C (GB/T 18380.3 / IEC 60332-3-24, Class C) YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 22 Steel tape armoured (double steel ...
High Capacity 5 Core Flex ZR-YJV 4x300mm2 + 1x150mm2 XLPE koper vlamvertrager
High Capacity 4+1 Core Cable ZR-YJV 4x300mm²+1x150mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
XLPE-geïsoleerde 5-kernkabel 5x10 mm2 kopergeleiderkabel voor commerciële bouw
XLPE Insulated ZR-YJV 5*10mm² Copper Conductor Cable for Commercial Construction Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
50 mm2 koper 5 kern gepantserde kabel XLPE voor indoor outdoor stroomverdeling
ZR-YJV 5 Core 50mm² Flame Retardant Copper Cable for Indoor & Outdoor Power Distribution Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...
Vlamvertragende 5-aderige kabel ZR-YJV 35mm2 XLPE Koper Gepantserd voor Hoofdvoedingen
Flame Retardant ZR-YJV 5 Core 35mm² Copper Cable for Building Main Power Feeds Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
8.2 8 6 mm 25 mm2 5 kern pantserkabel omhuld flexibel Voor binnenverspreidingssystemen
5 Core 25mm² ZR-YJV Flame Retardant Copper Cable for Indoor Power Distribution Systems Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...
5x16mm2 5 Aders Kabel Koper Xlpe Geïsoleerd Gepantserd Voor Gebouw MEP Werken
5*16mm² Flame Retardant Power Cable ZR-YJV Copper Conductor for Building MEP Works Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, ...
4x10mm2+1x6mm2 XLPE koperkabel 0,6kV 1kV vlamvertrager
ZR-YJV 4x10mm²+1x6mm² XLPE Copper Cable 0.6/1kV Flame Retardant Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant ...
Aarde 5 Aders Kabel 4x70mm2+1x35mm2 XLPE Koper Vlamvertragend 600 1000V
5 Core + Earth Cable ZR-YJV 4x70mm²+1x35mm² XLPE Copper Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...