5 كابل الأساسية
كابل ZC-YJV22 ذو 5 نوى 3x185 مم2 + 2x95 مم2 مدرع XLPE مقاوم للحريق 0.6/1kV
ZC-YJV22 5 Core 3x185mm²+2x95mm² Armored XLPE Flame Retardant Copper Cable 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Category C (GB/T 18380.3 / IEC 60332-3-24, Class C) YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 22 Steel tape armoured (double steel ...
كابل مرن عالي السعة 5 نوى ZR-YJV 4x300 مم2 + 1x150 مم2 XLPE نحاسي مقاوم للحريق
High Capacity 4+1 Core Cable ZR-YJV 4x300mm²+1x150mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
XLPE عازل 5 قلوب كابل 5x10mm2 كابل موصل النحاس للبناء التجاري
XLPE Insulated ZR-YJV 5*10mm² Copper Conductor Cable for Commercial Construction Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
كابل نحاسي مدرع 50 مم مربع 5 سنون XLPE للتوزيع الداخلي والخارجي للطاقة
ZR-YJV 5 Core 50mm² Flame Retardant Copper Cable for Indoor & Outdoor Power Distribution Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...
مضاد للنار 5 نواة كابل ZR-YJV 35mm2 Xlpe النحاس المدرع لتغذية الطاقة الرئيسية
Flame Retardant ZR-YJV 5 Core 35mm² Copper Cable for Building Main Power Feeds Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
8.2 - 8.6 مم 25 مم2 5 نواة كابل مدرع مغلف مرن لأنظمة توزيع الطاقة الداخلية
5 Core 25mm² ZR-YJV Flame Retardant Copper Cable for Indoor Power Distribution Systems Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...
كابل نحاسي معزول XLPE مدرع 5x16 مم2 5 نوى للأعمال الميكانيكية والكهربائية والصحية (MEP)
5*16mm² Flame Retardant Power Cable ZR-YJV Copper Conductor for Building MEP Works Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, ...
كابل نحاس XLPE 4x10 مم2 + 1x6 مم2 0.6 كيلو فولت 1 كيلو فولت مقاوم للهب
ZR-YJV 4x10mm²+1x6mm² XLPE Copper Cable 0.6/1kV Flame Retardant Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant ...
الأرض 5 نواة كابل 4x70mm2 + 1x35mm2 XLPE النحاس مضاد للنار 600 1000 فولت
5 Core + Earth Cable ZR-YJV 4x70mm²+1x35mm² XLPE Copper Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...