logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us
Search Results For:

"xlpe copper conductor cable"

- 90 Items Found
Quality Giant MV Cable YJV22 3x400mm² 8.7/15kV Armored XLPE Power Cable factory

Giant MV Cable YJV22 3x400mm² 8.7/15kV Armored XLPE Power Cable

Giant MV Cable YJV22 3x400mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; Uₘ = ...

Quality Lightweight Aluminum Cable 3 Core 35mm² YJLV22 8.7/10kV Armored XLPE factory

Lightweight Aluminum Cable 3 Core 35mm² YJLV22 8.7/10kV Armored XLPE

Lightweight Aluminum Cable 3 Core 35mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor ​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...

Quality Aluminum XLPE Cable YJLV22 3x70mm² 8.7/15kV Armored MV Power Cable factory

Aluminum XLPE Cable YJLV22 3x70mm² 8.7/15kV Armored MV Power Cable

Aluminum XLPE Cable YJLV22 3x70mm² 8.7/15kV Armored MV Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor ​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...

Quality Aluminum Concentric Neutral Mv Cable 3x95mm2 3 Core Aluminium Armoured Cable factory

Aluminum Concentric Neutral Mv Cable 3x95mm2 3 Core Aluminium Armoured Cable

Main Distribution Aluminum Cable YJLV22 3x95mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor ​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...

Quality 3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable factory

3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable

Industrial Main Aluminum Cable YJLV22 3x120mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor ​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...

Quality 8.7KV 10kV  Mv Power Cable Armored  Skyscraper Main Aluminum Cable factory

8.7KV 10kV Mv Power Cable Armored Skyscraper Main Aluminum Cable

Skyscraper Main Aluminum Cable YJLV22 3x400mm2 8.7/10kV 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor ​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7...

Quality YJV22 Medium Voltage Power Cable 3x150mm2 Copper Mv Armoured Cable 15kV factory

YJV22 Medium Voltage Power Cable 3x150mm2 Copper Mv Armoured Cable 15kV

YJV22 3x150mm² Copper XLPE Armored MV Cable 8.7/15kV Reliable Underground Power Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 22 Steel tape armoured (double steel tape) 3×150 mm² Three cores, each 150 mm² copper Construction : Copper ...

Quality YJLV22 3x150mm2 Copper HV High Voltage Power Cable XLPE Armored 26 35kV Underground factory

YJLV22 3x150mm2 Copper HV High Voltage Power Cable XLPE Armored 26 35kV Underground

YJLV22 3x150mm² Copper XLPE Armored HV Cable 26/35kV High Voltage Underground Cable Designation & Meaning Code Meaning 26/35 kV Rated voltage: U₀ = 26 kV (phase-to-earth), U = 35 kV (phase-to-phase) YJ XLPE (cross-linked polyethylene) insulation L Aluminium Conductor V PVC outer sheath 22 Steel tape ...

Quality 0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits factory

0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits

0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×70 mm² + 1×35 mm² Three phase ...

Prev 6 7 8 9 10 Next