"varies by core size flexible control wire cable standard color coding"
- 9 Items Found
2 Core 4 Core Flexible Cable Flexible PVC Wire 1.0mm2 For Instrumentation Wiring
Flexible PVC Wire 2 Core 1.0mm² RVV for Instrumentation Wiring Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 2×1.0 mm² Two flexible cores, each 1.0 mm² copper conductor ...
Power Cord 4 Core Flexible Cable 2 Core 4.0mm2 RVV For Air Conditioner Circuit
Power Cord Cable 2 Core 4.0mm² RVV-2*4.0mm² for Air Conditioner Circuit Cable Designation & Meaning Code Meaning R Flexible conductor V PVC insulation V PVC sheath 2×4.0 mm² Two cores of 4.0 mm² copper conductor Construction : Two 4.0 mm² fine-stranded copper conductors, PVC insulation on each core, ...
Power 4 Core Flexible Cable 2 Core 6.0mm2 RVV For Water Heater Circuit
Flexible Power Cable 2 Core 6.0mm² RVV-2*6.0mm² for Water Heater Circuit Cable Designation & Meaning Code Meaning R Flexible conductor V PVC insulation V PVC sheath 2×6.0 mm² Two cores of 6.0 mm² copper conductor Construction : Two 6.0 mm² fine-stranded copper conductors, PVC insulation on each core...
4x10mm2+1x6mm2 XLPE Copper Cable 0.6kV 1kV Flame Retardant
ZR-YJV 4x10mm²+1x6mm² XLPE Copper Cable 0.6/1kV Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×10 mm² + 1×6 mm² Four cores of 10 mm² (3 phase + 1 neutral) + one earth core of 6 mm² ...
4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV
4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×16 mm² + 1×10 mm² Four cores of 16 mm² (3 phase + 1 neutral) + one ...
ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation
ZR-YJV 1*300mm² Flame Retardant Single Core Cable, 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×300 mm² Single core, 300 ...
0.6/1kV XLPE Copper Cable ZR-YJV 4x25mm²+1x16mm² Flame Retardant for Power Supply
0.6/1kV XLPE Copper Cable ZR-YJV 4x25mm²+1x16mm² Flame Retardant for Power Supply Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×25 mm² + 1×16 mm² Four cores of 25 mm² (3 phase + 1 neutral) + one ...
Earth 5 Cores Cable 4x70mm2+1x35mm2 XLPE Copper Flame Retardant 600 1000V
5 Core + Earth Cable ZR-YJV 4x70mm²+1x35mm² XLPE Copper Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×70 mm² + 1×35 mm² Four cores of 70 mm² (3 phase + 1 neutral) + one ...
ZR-YJV 4*10mm² Flame Retardant 4 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power
ZR-YJV 4*10mm² Flame Retardant 4 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×10 mm² Four equal cores of 10 mm² copper ...