logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us
Search Results For:

"standard color coding flexible control wire cable"

- 51 Items Found
Quality Class 2 x 25mm2 2 Cores Cable Flame Retardant Copper Cable Xlpe Insulation Pvc Sheath factory

Class 2 x 25mm2 2 Cores Cable Flame Retardant Copper Cable Xlpe Insulation Pvc Sheath

ZR-YJV 2*25mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Power Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×25 mm² Two cores, 25 mm² copper conductor each ...

Quality Low Voltage 4 Cores Cable ZR-YJV 3×35mm2+1×16mm2 XLPE Cable factory

Low Voltage 4 Cores Cable ZR-YJV 3×35mm2+1×16mm2 XLPE Cable

Low Voltage Flame Retardant ZR-YJV 3×35mm²+1×16mm² XLPE Cable for Mobile Power Distribution Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...

Quality OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty factory

OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty

Flame Retardant Copper Conductor ZR-YJV 3×50mm²+1×25mm² for Heavy-Duty Three Phase Supply Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×50 mm² + 1×25 mm² Three phase cores of 50 mm² + one neutral ...

Quality 4+1 Core Fire Resistant Cable 120mm2+1x70mm2 BTTRZ Fire Substation Cable factory

4+1 Core Fire Resistant Cable 120mm2+1x70mm2 BTTRZ Fire Substation Cable

Fire Substation Cable 4+1 Core 120mm²+1x70mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×120 mm² Four cores of 120 mm² copper conductor (3 phase + 1 neutral) +1×70 mm² One core of 70 mm² ...

Quality 2 X 70mm2 2 Cores Cable ZR-YJV Flame Retardant  PVC Insulation Jacket 0.6/1kV factory

2 X 70mm2 2 Cores Cable ZR-YJV Flame Retardant PVC Insulation Jacket 0.6/1kV

ZR-YJV 2*70mm² Flame Retardant 2 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×70 mm² Two cores, 70 mm² copper conductor ...

Quality 4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV factory

4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV

4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×16 mm² + 1×10 mm² Four cores of 16 mm² (3 phase + 1 neutral) + one ...

Quality 0.6/1kV XLPE Copper Cable ZR-YJV 4x25mm²+1x16mm² Flame Retardant for Power Supply factory

0.6/1kV XLPE Copper Cable ZR-YJV 4x25mm²+1x16mm² Flame Retardant for Power Supply

0.6/1kV XLPE Copper Cable ZR-YJV 4x25mm²+1x16mm² Flame Retardant for Power Supply Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×25 mm² + 1×16 mm² Four cores of 25 mm² (3 phase + 1 neutral) + one ...

Quality Earth 5 Cores Cable 4x70mm2+1x35mm2 XLPE Copper Flame Retardant 600 1000V factory

Earth 5 Cores Cable 4x70mm2+1x35mm2 XLPE Copper Flame Retardant 600 1000V

5 Core + Earth Cable ZR-YJV 4x70mm²+1x35mm² XLPE Copper Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×70 mm² + 1×35 mm² Four cores of 70 mm² (3 phase + 1 neutral) + one ...

Quality ZR-YJV 4*10mm² Flame Retardant 4 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power factory

ZR-YJV 4*10mm² Flame Retardant 4 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power

ZR-YJV 4*10mm² Flame Retardant 4 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×10 mm² Four equal cores of 10 mm² copper ...

Prev 2 3 4 5 6 Next