Class 2 x 25mm2 2 Cores Cable Flame Retardant Copper Cable Xlpe Insulation Pvc Sheath
ZR-YJV 2*25mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Power Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×25 mm² Two cores, 25 mm² copper conductor each ...
3+1 Core Flame Retardant 4 Cores Cable For Factory Three Phase Main Power
ZR-YJV 3+1 Core Flame Retardant Copper Cable 3x16mm²+1x10mm² for Factory Three-Phase Main Power Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC ...
Aluminum Conductor XLPE Cable 3 Core 25mm² YJLV22 8.7/10kV Armored
Aluminum Conductor XLPE Cable 3 Core 25mm² YJLV22 8.7/10kV Armored Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
High Capacity MV Cable YJV22 3x95mm² 8.7/15kV Armored XLPE Power Cable
High Capacity MV Cable YJV22 3x95mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
Fire Resistant Cable BTTRZ 4x50mm²+1x25mm² Mineral Insulated 0.6/1kV
Fire Resistant Cable BTTRZ 4x50mm²+1x25mm² Mineral Insulated 0.6/1kV Technical Datasheet — BTTRZ 0.6/1 kV 4×50 mm² + 1×25 mm² Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = ...
5 Core Multi Core Control Cable 0.75mm2 RVV For Building Automation
Multi Core Control Cable 5 Core 0.75mm² RVV for Building Automation Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 5×0.75 mm² Five flexible cores, each 0.75 mm² copper ...
2 X 70mm2 2 Cores Cable ZR-YJV Flame Retardant PVC Insulation Jacket 0.6/1kV
ZR-YJV 2*70mm² Flame Retardant 2 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×70 mm² Two cores, 70 mm² copper conductor ...
BTTRZ 0.6/1kV 4x50mm²+1x25mm² Fire-resistant Cable for Industrial Emergency Feeders
BTTRZ 0.6/1kV 4x50mm²+1x25mm² Fire-resistant Cable for Industrial Emergency Feeders Cable Designation & Meaning Code Meaning B Fixed wiring T Copper conductor T Copper sheath R Flexible Z Heavy duty 4×50 mm² Four cores of 50 mm² copper conductor (phases) +1×25 mm² One core of 25 mm² copper conductor ...
Low Voltage 4 Cores Cable ZR-YJV 3×35mm2+1×16mm2 XLPE Cable
Low Voltage Flame Retardant ZR-YJV 3×35mm²+1×16mm² XLPE Cable for Mobile Power Distribution Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...