BVR 2.5mm² Flexible Copper Wire PVC Insulated Easy Routing for Indoor Building Electrical Wiring

BVR 2.5mm² Flexible Copper Wire PVC Insulated Easy Routing for Indoor Building Electrical Wiring

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
BVR-2.5mm²

Trading Properties

moq
100 meters
unit price
USD 0.13-0.16/Meter
payment method
L/C,T/T
supply capacity
100000 rolls per month

Product Summary

BVR 2.5mm² Flexible Copper Wire PVC Insulated Easy Routing for Indoor Building Electrical Wiring Cable Designation & Meaning Code Meaning B Fixed wiring V PVC insulation R Flexible— stranded conductor 1×2.5 mm² Single core of 2.5 mm² copper conductor Construction: One 2.5 mm² stranded copper ...

Product Details

Conductor nominal area:
2.5 Mm² (Cu) × 1
Number of cores:
1 (single-core)
Conductor material:
Copper (Cu)
Conductor class:
Class 2 Stranded
Conductor construction:
19×∅0.41 Mm
Conductor diameter:
≈ 2.1 Mm
Insulation thickness (nom.):
0.8 Mm
Insulation thickness (min.):
0.62 Mm
Overall cable diameter:
3.6 – 4.5 Mm
Design outer diameter:
≈ 4.0 Mm
Approx. weight:
30 – 42 Kg/km
Design weight:
≈ 38 Kg/km
Cable shape:
Round

Product Description

BVR 2.5mm² Flexible Copper Wire PVC Insulated Easy Routing for Indoor Building Electrical Wiring

Cable Designation & Meaning

Code

Meaning

B

Fixed wiring 

V

PVC insulation 

R

Flexible— stranded conductor

1×2.5 mm²

Single core of 2.5 mm² copper conductor

Construction: One 2.5 mm² stranded copper conductor (Class 2 or Class 5), PVC insulation applied directly over the conductor.


BVR 2.5mm² Flexible Copper Wire PVC Insulated Easy Routing for Indoor Building Electrical Wiring

BVR 1×2.5 mm² — Single-Core Stranded PVC Insulated Flexible Building Wire 

1. Overview & Ratings

BVR 1×2.5 is a single-core PVC insulated flexible building wire rated 450/750 V. It uses pure annealed bare copper (not tinned) in a Class 5 stranded lay-up, chosen for high conductivity and easy bending in panels and tight runs. One 2.5 mm² copper bundle is covered by a continuous PVC insulation; there is no braid shield, no inner sheath and no outer jacket. Finished OD ≈ 3.6 mm, ≈ 30 kg/km (est.), ≈ 20–25 A in conduit. Max conductor temperature 70 °C, -15 to +70 °C. Intended for fixed indoor and panel wiring; not for trailing drag chains, outdoor UV exposure or direct burial.

2. Construction Stack (Inner → Outer, expanded)

Layer / Feature Build Function
Conductor Pure annealed Cu, stranded Class 5, 49×0.25 mm R ≤ 7.41 Ω/km, flexible fixed wiring
Insulation PVC ≈ 0.8 mm wall, colour-coded 450/750 V dielectric, circuit identification
Shield None Single-core unshielded wire
Outer jacket None Insulation forms the outer layer

3. Electrical Characteristics

DC resistance ≤ 7.41 Ω/km at 20 °C per GB/T 3956 Class 5 pure copper. Rated voltage 450/750 V. Estimated ampacity ≈ 20–25 A in conduit at 30 °C, up to ≈ 32 A in free air, with derating for grouping and enclosure. Insulation resistance ≥ 20 MΩ·km. Routine AC withstand test at 2000 V for 5 minutes. Typical capacitance ≈ 150 pF/m at 1 kHz. As a single-core wire it carries one phase, neutral or earth conductor per run; circuit identification is handled by insulation colour rather than internal pairing.

Insulation & Sheath Data

Property

Value

Insulation material

PVC (Type TI1 or TI2)

Outer sheath material

None​ (non-sheathed)

Shield material

None​

Long-term service temp.

70 °C (continuous, TI1/TI2)

Max. conductor temp. (normal)

70 °C

Short-circuit temp. (≤5 s)

160 °C

Emergency overload temp.

100 °C (≤1 h)

Test voltage AC (5 min)

2.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹² Ω·cm

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

450 / 750 V

GB/T 5023.3 (fixed wiring)

Max. system voltage

500 V AC / 750 V DC

—

Test voltage AC (5 min)

2.5 kV

Routine test

DC resistance @20 °C

≤ 7.41 Ω/km (Class 2) / ≤ 7.98 Ω/km (Class 5)

GB/T 3956 max

AC resistance @70 °C (est.)

≈ 9.28 Ω/km (Class 2)

—

Current rating in air (30 °C)

25 A​ (reference, single-core open)

typical

Current rating in conduit (30 °C)

21 A​ (reference, 2-core conduit)

typical installation

DC current capacity

24 A​

—

Short-circuit current (1 s, Cu, 160 °C)

≈ 275 A

—

Capacitance (core-to-ambient, approx.)

≈ 0.11 µF/km

PVC

Inductive reactance (approx.)

≈ 0.10 Ω/km

at 50 Hz (single-core)

Frequency

50/60 Hz AC, DC

—


Reference values: BVR 2.5 at 21–25 A, 230 V AC → max load ≈ 4,830–5,750 VA​ (typical lighting/socket/control circuit). At 24 V DC → max load ≈ 576 W.

4. Thermal & Flame Behaviour

Operating range -15 to +70 °C continuous. Short-circuit withstand up to 160 °C for ≤ 5 seconds. The PVC insulation is flame-retardant per IEC 60332-1 and self-extinguishing after the ignition source is removed. The cable is halogen-containing (PVC), emitting HCl gas on burning — avoid in enclosed public or high-density spaces where LSZH wiring is required. The insulation surface is smooth and oil-limited; protect it from direct sunlight, solvents and prolonged moisture. Bare copper should be terminated in dry, enclosed locations.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

70 °C (continuous)

Max. short-circuit temp. (≤5 s)

160 °C

Emergency overload temp.

100 °C (≤1 h)

Min. installation ambient temp.

−15 °C

Service ambient range

−15 °C to +70 °C

Flexing temp. range

−5 °C to +70 °C (Class 5); 0 °C to +70 °C (Class 2)

Fire Performance (BVR — PVC, Non-Low-Smoke)

Property

Value / Requirement

Flame retardant

GB/T 18380.3 / IEC 60332-3​ (Category A/B/C as specified)

Halogen content

Contains halogen​ (PVC)

Smoke density

Not low-smoke​ (IEC 61034-2 not applicable)

Corrosivity

Corrosive​ (HCl emission from PVC)

Toxicity

Toxic fumes​ when burned (CO, HCl)

EMI shielding

None​

UV resistance

Poor​ (PVC degrades outdoors, use conduit)

Water resistance

Limited​ (PVC insulation only)

5. Installation Practice & Handling

Minimum bending radius ≥ 4×OD ≈ 14 mm. The Class 5 stranded core is suppler than a solid wire, so it dresses around panel corners, terminal rows and tight duct bends without kinking. Terminate by stripping the insulation, terminating the bundle in a ferrule, lug or terminal block, and tightening to the rated torque. Group live, neutral and earth conductors in the same conduit; keep green-yellow earth wires separate in identification. After installation, verify insulation resistance and continuity before energizing. Do not use as a trailing appliance cord or drag-chain cable.

Mechanical & Installation Parameters

Parameter

Value (Class 2)

Value (Class 5)

Remarks

Minimum bending radius

≥ 4 × OD → ≈ 16 mm

≥ 4 × OD → ≈ 18 mm

stranded conductor

Max. pulling tension

37.5 N (2.5 mm² × 15 N/mm²)

37.5 N (2.5 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Not recommended​ (PVC, no sheath)

Not recommended​

—

Surface mounting

Conduit, trunking, cable tray, DIN rail

Conduit, trunking, cable tray

—

Conduit ID

≥ 16 mm (single), ≥ 20 mm (multiple)

≥ 16 mm (single), ≥ 20 mm (multiple)

—

Fixing

cable ties, clips, staples

cable ties, clips, staples

—

Impact resistance

Low (PVC)

Low (PVC)

—

Water resistance

Limited​ (no sheath)

Limited​ (no sheath)

—

UV resistance

Poor​ (indoor/conduit only)

Poor​ (indoor/conduit only)

—

Flex life

Good​ (Class 2, occasional bending)

Excellent​ (Class 5, frequent bending)

—

Termination note

Compression lugs (2.5 mm²), crimp terminals, screw terminals

Compression lugs (2.5 mm²), crimp terminals, screw terminals

—

6. Typical Service Applications

Panel internal wiring and switchboard connections, vibrating equipment and motor terminal leads where flexibility matters, tight-bend runs in control cabinets, distribution board internal conductors, and fixed indoor lighting and socket branch circuits. The stranded construction is preferred where the wire must bend around obstructions or connect to equipment subject to vibration, while still serving as a fixed wiring conductor. Typical installation: conduit, trunking, cable tray and panel raceway. It is not designed for: shielded signal transmission, trailing or moving equipment, outdoor UV-exposed runs, submersible or buried circuits, or high-temperature heater wiring.

.


BVR 2.5mm² Flexible Copper Wire PVC Insulated Easy Routing for Indoor Building Electrical Wiring

7. Testing & Quality Assurance Regime

Routine tests (100% production): DC resistance, AC voltage withstand (2000 V/5 min), insulation resistance, conductor construction, insulation thickness, dimensional check, print legibility, mass per length, visual appearance, and packing. Type tests (per batch / material change): heat aging (100 °C/7 days), cold bend (-15 °C), insulation tensile and elongation, flame retardancy, conductor flexibility under repeated bending, and wall thickness uniformity. Every coil ships with mill test certificate, ROHS and REACH declarations. The 450/750 V rating uses a 2000 V withstand test.


The Wire Parameters


BVR 1×2.5 mm² — Full Parameter Sheet
Single-core PVC insulated flexible building wire · 450/750 V · pure annealed Cu stranded Class 5 · PVC insulation · no shield, no outer jacket · GB/T 5023 / IEC 60227
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type BVR — Single-core, PVC insulated, stranded pure Cu

Rated voltage (U0/U) 450/750 V Fixed indoor / panel wiring

Number of cores 1 — Single core, stranded

Nominal cross-section 2.5 mm² Per core, Class 5 flexible

Conductor material Pure annealed copper (bare) — Class 5 per GB/T 3956, not tinned

Insulation material PVC — 70 °C rated, 0.8 mm wall

Shield None — No braid / foil on single-core wire

Outer jacket None — Insulation forms the outer layer

Standard reference GB/T 5023 / IEC 60227 / JB/T 8734 — PVC insulated flexible wiring wire
02 · Conductor

Conductor form Stranded (flexible) — Class 5

Stranding 49 × 0.25 mm — Pure copper wires per core

Conductor bundle Ø ≈ 2.05 mm Strand-lay diameter

DC resistance @ 20 °C ≤ 7.41 Ω/km Maximum per GB/T 3956 (pure Cu)

Conductor surface Bare pure copper — Not tinned; fixed indoor use
03 · Insulation

Insulation type PVC — Soft PVC, 70 °C

Insulation thickness ≈ 0.8 mm Nominal

Finished diameter ≈ 3.6 mm Insulation outer Ø

Insulation resistance ≥ 20 MΩ·km At 20 °C
04 · Lay-Up & Shield

Core lay-up Not applicable — Single-core wire

Filler / bedding None — No inner sheath on BVR

Shield type None — Unshielded building wire

Shield coverage — — Not applicable
05 · Insulation Finish

Outer surface Smooth PVC extrusion — Colour-coded

Printing Designation / size / voltage / metre mark — At regular intervals

Insulation colours Red, yellow, blue, green-yellow, black, white — Order colour at purchase
06 · Electrical

Rated voltage 450/750 V Fixed wiring

Test voltage (AC) 2000 V AC 5 min routine

DC resistance @ 20 °C ≤ 7.41 Ω/km Per GB/T 3956 (pure Cu)

Ampacity (conduit, est.) ≈ 20–25 A 2.5 mm², 70 °C

Ampacity (free air, est.) Up to ≈ 32 A Derate for grouping / enclosure

Capacitance ≈ 150 pF/m At 1 kHz
07 · Thermal & Mechanical

Max continuous conductor temp. 70 °C Normal service

Short-circuit temp. (≤5 s) 160 °C Copper limit

Min. ambient temp. -15 °C Fixed installation

Min. bending radius ≥ 4 × OD ≈ 14 mm Flexible stranded core

Halogen content Halogen-containing — PVC compound
08 · Flame & Environment

Flame retardancy IEC 60332-1 — Single vertical flame

Oil resistance Limited — PVC insulation

UV resistance Limited — Indoor / conduit use

Corrosion resistance Limited (bare Cu) — Dry indoor only; use tinned variant for damp/outdoor

ROHS / REACH Compliant — EU 2011/65/EU


The Wire Test Parameters


Test Parameters — BVR 1×2.5 mm²
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 7.41 Ω/km Routine
2 AC voltage withstand 2000 V AC, 5 min No breakdown Routine
3 Insulation resistance 500 V megohmmeter ≥ 20 MΩ·km Routine
4 Conductor construction Visual + strand count 49 × 0.25 mm pure Cu stranded Routine
5 Insulation thickness Micrometer cross-section ≈ 0.8 mm Routine
6 Dimensional check Caliper OD ≈ 3.6 mm Routine
7 Print legibility Visual + rubbing Marks legible Routine
8 Mass per unit length Weighing ≈ 30 kg/km Routine
9 Appearance Visual Smooth, uniform colour, no blisters Routine
10 Packing Visual Coil, sealed ends, labelled Routine
11 Heat aging test 7 days at 100 °C Retention ≥ 70% Type
12 Cold bend test -15 °C, 4 h mandrel No cracking Type
13 Insulation tensile & elongation Universal tester Meets GB/T 5023 min. Type
14 Flame retardancy IEC 60332-1 Self-extinguish Type
15 Conductor flexibility Mandrel bend, repeat cycles No strand break, no insulation damage Type
16 Wall thickness uniformity Micrometer at 4 points Min. wall ≥ nominal − tolerance Type


Cross Section Structure


BVR 2.5mm² Flexible Copper Wire PVC Insulated Easy Routing for Indoor Building Electrical Wiring

BVR 1×2.5 mm² — Cross-Section Construction Diagram (Schematic)
Layered build-up: pure copper stranded Class 5 conductor (single core) → PVC insulation · 450/750 V single-core PVC insulated flexible building wire · panel internal wiring / vibrating equipment / tight bends · no shield, no outer jacket · -15~+70 °C
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor Pure annealed copper, stranded Class 5 — 49 × 0.25 mm wires — ≈ 2.05 (strand bundle) Flexible fixed wiring; R ≤ 7.41 Ω/km; bare pure copper for high conductivity
2 Insulation PVC compound, extruded over the stranded conductor, colour-coded ≈ 0.8 ≈ 3.6 (finished) Primary electrical insulation; 450/750 V rated; colour identifies circuit polarity






Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 3.6 mm Single-core stranded flexible wire (est.)
Approximate cable mass ≈ 30 kg/km Pure Cu stranded + PVC insulation
Nominal voltage rating 450/750 V Fixed indoor / panel wiring
Max continuous conductor temp. 70 °C Normal service
Min. ambient / installation temp. -15 °C Fixed installation
DC resistance @ 20 °C ≤ 7.41 Ω/km Class 5 pure copper, GB/T 3956
Core count × cross-section 1 × 2.5 mm² Single core, stranded
Shielding None — Single-core wire, no braid / foil
Insulation resistance ≥ 20 MΩ·km PVC at 20 °C
Test voltage (AC) 2000 V AC / 5 min — Routine withstand test
Flame retardancy IEC 60332-1 — Single vertical flame
Insulation colours Red / yellow / blue / green-yellow / black / white — Order colour at purchase
Jacket colour — — BVR has no outer jacket; insulation is the outer layer
Mass per 100 m ≈ 3.0 kg/100 m For coil loading
Reference standard GB/T 5023 / IEC 60227 / JB/T 8734 — PVC insulated flexible fixed wiring wire
Schematic — not to exact scale. Finished Ø ≈ 3.6 mm and weight ≈ 30 kg/km from cross-referenced industry samples; stranded pure copper conductor 49/0.25 mm, 0.8 mm PVC insulation. Pure copper (not tinned). Est. values confirmed against factory type certificate.


Construction Description


Construction Description — BVR 1×2.5 mm²
Layer-by-layer build-up narrative · 450/750 V single-core PVC insulated flexible building wire · GB/T 5023 / IEC 60227 · pure annealed copper stranded Class 5 conductor / PVC insulation
1. Product Identity & Ratings
BVR 1×2.5 is a single-core PVC insulated flexible building wire rated 450/750 V. The conductor is pure annealed bare copper (not tinned), stranded in a Class 5 flexible lay-up for easy bending in panels and tight runs. One 2.5 mm² stranded copper core is insulated by a continuous PVC extrusion. There is no braid shield, no inner sheath and no outer jacket. OD ≈ 3.6 mm, ≈ 30 kg/km. Max 70 °C, -15 to +70 °C. Intended for fixed indoor and panel wiring; not for moving drag chains or outdoor UV exposure.
2. Pure Copper Stranded Conductor
The 2.5 mm² conductor is stranded from 49 pure annealed copper wires of 0.25 mm in a Class 5 flexible lay-up. Stranding keeps the wire supple around panel corners, terminal rows and tight duct bends, while DC resistance stays ≤ 7.41 Ω/km at 20 °C per GB/T 3956. Pure bare copper provides high conductivity for fixed installation; for damp or outdoor locations a tinned or insulated variant should be considered.
3. PVC Insulation
A 0.8 mm PVC compound is extruded continuously over the stranded copper bundle, forming the only insulating and outer layer. The insulation provides the primary electrical barrier for 450/750 V circuits, with insulation resistance ≥ 20 MΩ·km at 20 °C. The PVC surface is smooth, uniform in wall thickness, and available in standard circuit colours.
4. Lay-Up & Colour Coding
As a single-core wire there is no stranding of multiple cores, fillers or bedding. Colour coding identifies the circuit: red for live/phase, blue for neutral, green-yellow for protective earth, with yellow, black and white as supplementary colours. Customers specify the required colour at order time; mixed-colour lots are cut and packaged separately to avoid installation errors.
5. Surface Marking & Application Range
The insulation surface is printed at regular intervals with the designation BVR, cross-section, voltage rating, manufacturer and metre mark. The wire is designed for fixed installation and flexible internal connections: panel internal wiring, vibrating equipment terminals, tight-bend runs, switchboard and distribution board connections. It is not a trailing appliance cable, not a shielded signal cable and not a submersible or direct-burial wire.

8. Factory Advantages

Pure annealed stranded copper delivers stable conductivity with a flexible, supple core that resists kinking in tight panels. Class 5 stranding keeps the wire dressable around corners and terminal rows. Continuous PVC extrusion gives a smooth, uniform wall with consistent colour and diameter. Standard circuit colours are available to prevent wiring errors at site. Ferrules seat cleanly on the stranded bundle, reducing loose-connection risk. 100% routine electrical QA on every coil. Cut-to-length packaging with sealed ends reduces waste. Lightweight ≈ 30 kg/km for easy coil handling. Full traceability with MTC and certification support for panel-build and building-wiring tenders.


BVR 2.5mm² Flexible Copper Wire PVC Insulated Easy Routing for Indoor Building Electrical Wiring

9. Packaging, Storage & Logistics

Cut to customer-specified length on export-grade coils, with both ends sealed to prevent moisture ingress. Coils wrapped in waterproof film and cardboard, labelled with designation BVR, cross-section, colour, length, weight, production date and reel number. Standard lengths 100/200/500/1000 m; custom lengths available. Store dry indoor, -10 to +40 °C, below 75% RH, away from direct sunlight, solvents and chemical fumes. FOB Shanghai/Nanjing/Qingdao; CIF and DAP available. Sample lead time 5–7 days; bulk production 15–25 days. Mixed-colour lots are packed and labelled separately.


BVR 2.5mm² Flexible Copper Wire PVC Insulated Easy Routing for Indoor Building Electrical Wiring

10. Procurement Specification

State wire designation "BVR 1×2.5 pure copper", required colour (red/blue/yellow/green-yellow/black/white), and length per coil. Request the routine AC withstand test record (2000 V) and DC resistance certificate for the specific batch. Note this is a pure copper (bare) flexible fixed-wiring variant for dry indoor use — for damp or outdoor locations, specify a tinned or appropriate insulated variant. Specify any regional certification requirements (CE, etc.) at order time. Payment: 30% T/T deposit, balance against B/L copy. Documents: MTC, ROHS/REACH, COO, commercial invoice, packing list.

11. Cable Industry FAQ

Q1: What does "BVR" mean? B denotes a copper conductor, V denotes PVC insulation, and R denotes a stranded flexible construction; BVR is the stranded flexible version of the BV building wire in IEC 60227 practice.

Q2: Why choose BVR over BV? The stranded Class 5 core is suppler and bends tighter than a solid wire, making BVR the preferred choice in panels, cabinets and vibrating equipment where BV solid would kink or fatigue.

Q3: Is the conductor solid or stranded? Stranded: 49 wires of 0.25 mm pure annealed copper in a Class 5 lay-up, DC resistance ≤ 7.41 Ω/km at 20 °C.

Q4: What is the voltage rating? 450/750 V, suitable for low-voltage fixed indoor and panel wiring.

Q5: What current can 2.5 mm² carry? ≈ 20–25 A in conduit, up to ≈ 32 A in free air, derated for grouping and enclosure; confirm against local wiring rules and circuit protection.

Q6: Why pure copper instead of tinned? Bare pure copper gives the highest conductivity for fixed indoor contacts; tinned copper is normally chosen where moisture or outdoor corrosion is a concern.

Q7: What do the colours mean? Red = live/phase, blue = neutral, green-yellow = protective earth; yellow, black and white are supplementary colours.

Q8: Does BVR have a shield? No — BVR is an unshielded single-core wire. For EMI-sensitive signal circuits, use a shielded RVVP-type multiconductor cable.

Q9: Can it be used outdoors? Not directly — limited UV resistance and bare copper oxidize in humidity. Install inside UV-protected conduit or choose an outdoor-rated cable.

Q10: What proof ships? Routine AC test record (2000 V) + DC resistance certificate + MTC.

Q11: What is the temperature range? -15 to +70 °C continuous. For high-temperature or flexible trailing-duty duty, a dedicated flexible or high-temperature cable should be specified instead.