Bvr 4.0mm2 Stranded Copper Conductor Pvc Insulated Flexible Building Wire

Bvr 4.0mm2 Stranded Copper Conductor Pvc Insulated Flexible Building Wire

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
BVR 4.0mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

BVR 4.0mm² Stranded Copper PVC Insulated Flexible Building Wire 450/750V Easy Bend Cable Designation & Meaning Code Meaning B Fixed wiring (Class B, fixed installation) V PVC insulation R Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal conductor cross-sectional area Construction: Fine...

Product Details

Highlight:

BVR Stranded Copper Conductor

,

4.0mm2 Stranded Copper Conductor

,

OEM Flexible Building Wire

Conductor:
Copper, Class 5 Fine-stranded Flexible, Nominal 56×∅0.30 Mm (4.0 Mm²), Conductor Ø ≈ 2.8–3.2 Mm
Insulation:
PVC (polyvinyl Chloride)​ Compound, Nominal Thickness 0.8 Mm (for 4.0 Mm² Per GB/T 5023.3), Colour: Various​ (red, Black, Blue, Yellow/green, White, Brown, Grey, Orange, Purple)
Conductor nominal area:
4.0 Mm²
Number of cores:
1
Conductor material:
Copper (Cu)
Conductor class:
Class 5 Fine-stranded Flexible
Conductor construction:
56×∅0.30 Mm
Conductor diameter (approx.):
2.8–3.2 Mm
Insulation thickness:
0.8 Mm
Overall cable diameter:
4.4 – 5.2 Mm
Design outer diameter:
≈ 4.8 Mm
Approx. weight:
0.048 – 0.055 Kg/m (48–55 Kg/km)
Design weight:
≈ 51 Kg/km
Cable shape:
Round

Product Description

BVR 4.0mm² Stranded Copper PVC Insulated Flexible Building Wire 450/750V Easy Bend

Cable Designation & Meaning

 

Code

Meaning

B

Fixed wiring (Class B, fixed installation)

V

PVC insulation

R

Flexible conductor (Class 5 fine-stranded)

4.0 mm²

Nominal conductor cross-sectional area

 

Construction: Fine-stranded flexible copper conductor, PVC insulation, single-core building wire.

Applicable Standards

  • GB/T 5023.3-2008 / IEC 60227-3 — Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V — Part 3: Non-sheathed cables for fixed wiring
  • GB/T 3956 / IEC 60228 — Conductors (Class 5 flexible copper)
  • GB/T 2951 / IEC 60811 — Insulating and sheathing materials — Common test methods
  • GB/T 18380 / IEC 60332-1 — Flame retardant (single cable, passes)
  • GB/T 5023.2-2008 / IEC 60227-2 — Test methods

Bvr 4.0mm2 Stranded Copper Conductor Pvc Insulated Flexible Building Wire

 

Bvr 4.0mm2 Stranded Copper Conductor Pvc Insulated Flexible Building Wire

 

BVR-4.0 mm² — Single-Core PVC Insulated Flexible Copper Building Wire — Specification & Engineering Data

1. Overview & Ratings. BVR-4.0 is a single-core PVC insulated flexible copper building wire rated 450/750 V, 70 °C continuous. Built per GB/T 5023 / IEC 60227. It uses a Class 5 fine-stranded copper conductor (~56×0.30 mm) for superior flexibility compared to rigid BV wire. Ideal for control panels, equipment leads, and tight conduit runs. Finished Ø ≈ 4.2 mm, ≈ 52 kg/km, supplied on 100 m coils.

 

2. Construction Stack (Conductor → Outer).

Layer Build Wall Diameter
Conductor Fine-stranded annealed Cu, Class 5, 4.0 mm² — ≈ 3.0 mm
PVC insulation Polyvinyl chloride, general-purpose ≈ 0.9 mm ≈ 4.2 mm (finished)

 

3. Electrical Characteristics. DC resistance ≤ 4.95 Ω/km at 20 °C (flexible Cu 4.0 mm²); test voltage 2.5 kV AC / 5 min; insulation resistance ≥ 20 MΩ·km. Nominal ampacity ≈ 32 A (in conduit, 30 °C). Voltage drop ≈ 1.8 V/A·100 m.

Insulation Data

Property

Value

Material

PVC (polyvinyl chloride)

Nominal thickness

0.8 mm

Long-term service temp.

70 °C (continuous, PVC Type TI1/TI2)

Short-circuit temp. (≤5 s)

160 °C (Cu conductor limit for PVC)

Emergency overload temp.

105 °C (short term, not recommended for continuous)

Test voltage AC (5 min)

2.0 kV (routine test, 450/750 V class)

Dielectric strength

≥ 15 kV/mm (room temp.)

Volume resistivity @20 °C

≥ 1.0×10¹² Ω·cm

Hardness (Shore A)

85–95

Electrical Parameters

 

Parameter

Value

Note

Rated voltage U₀/U

450 / 750 V

GB/T 5023.3 / IEC 60227-3

Max. system voltage

500 V AC (between conductors)

—

Test voltage AC (5 min)

2.0 kV

Routine test

DC resistance @20 °C

≤ 4.95 Ω/km

GB/T 3956 Class 5 Cu max, 4.0 mm²

AC resistance @70 °C (est.)

≈ 6.3 Ω/km

—

Current rating in air (30 °C, single-core)

36 A​

single-core open air, reference value

Current rating in conduit (30 °C, 1-core)

28 A​

in conduit, reference value

Current rating (multi-core bundle, conduit)

24 A​

bundled with other circuits (typical derating)

Short-circuit current (1 s, Cu, 160 °C)

≈ 0.44 kA (440 A)

4.0 mm² Cu

Frequency

50/60 Hz AC

—

Reference values: 4.0 mm² Cu at 28 A (conduit), single-phase 230 V → max load ≈ 6.4 kW. Voltage drop at 28 A ≈ 176 V/km (≈7.6% per 100 m at 230 V — limit to ≤ 50 m run without upsize).

 

4. Thermal & Mechanical. 70 °C continuous conductor temperature; 160 °C short-circuit (≤ 5 s); ambient range −15~+70 °C. Bend ≥ 2 × OD ≈ 8 mm — very flexible. Resists metal fatigue from repeated bending.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

70 °C (continuous)

Max. short-circuit temp. (≤5 s)

160 °C (Cu conductor, PVC limit)

Emergency overload temp.

105 °C (not recommended for continuous)

Min. installation ambient temp.

0 °C (PVC); below 0 °C pre-heating required

Service ambient range

−15 °C to +70 °C (PVC insulation)

Fire survival

Standard (flame retardant single cable)

Fire Performance (BVR — Standard)

Property

Value / Requirement

Flame retardant

IEC 60332-1 (single cable, passes)

Halogen content

Contains halogen (PVC)

Smoke density

Standard (non-low-smoke)

Corrosivity

Corrosive (PVC)

Fire survival (circuit integrity)

Not applicable (standard version)

 

5. Installation Practice & Handling. Pull into conduit or trunking. Use wire stripper carefully — fine strands cut easily. Crimp lugs rated for flexible conductors. At 52 kg/km, lightweight. Indoor use only — not for outdoor UV exposure.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 4 × OD → ≈ 19 mm at Ø4.8 mm

flexible conductor

Max. pulling tension

160 N

fine-stranded Cu (handle gently)

Direct burial

Not recommended​ (no mechanical protection; use PVC conduit or cable tray)

—

Conduit ID

≥ 1.5 × OD → ≥ 7.2 mm; use 16 mm or 20 mm conduit

—

Fixing

cable ties, clips, conduit

—

Impact resistance

Low (PVC insulation only)

use conduit in exposed areas

Water resistance

Moisture-resistant (PVC)

not waterproof; avoid prolonged immersion

UV resistance

Poor (PVC degrades in sunlight)

indoor use only; outdoor requires UV-resistant conduit

Termination note

Strip 10–12 mm insulation; use standard screw terminals or compression lugs

fine strands require ferrules for screw terminals

 

6. Typical Service Applications. Control panel wiring, equipment leads, appliance connections, tight conduit runs, socket outlets — where flexibility and bend resistance are needed.

 

Bvr 4.0mm2 Stranded Copper Conductor Pvc Insulated Flexible Building Wire

 

7. Testing & QA Regime. Routine: conductor DC resistance, 2.5 kV AC / 5 min withstand, insulation resistance, insulation thickness. Type: heating test, flexibility/bending test, flame retardancy, cold bend at −15 °C.

 

The Wire Parameters

 

BVR-4.0 mm² — Single-Core PVC Insulated Flexible Copper Building Wire — Full Parameter Sheet 
Flexible building wire · fine-stranded copper conductor / PVC insulation · 450/750 V · 70 °C · finished Ø ≈ 4.2 mm
Section Parameter Value Unit Remarks / Standard
01 · Identification
  Cable type BVR — single-core PVC insulated flexible copper building wire — Flexible fixed wiring
  Rated voltage (U0/U) 450/750 V Building / indoor
  Number of cores 1 — Single-core
  Conductor material Annealed copper, fine-stranded — Class 5 flexible per GB/T 3956
  Insulation material PVC (polyvinyl chloride) — General-purpose
  Standard GB/T 5023 / IEC 60227 — Building wire
  Application Flexible fixed wiring, panel wiring, equipment leads — Building electrical
  Color options Red / blue / yellow / green / black / yellow-green — Phase / neutral / earth
  Flame retardancy Basic (PVC) — Self-extinguishing
02 · Conductor (Flexible Cu)
  Conductor type Fine-stranded annealed copper — Class 5 flexible
  Conductor area 4.0 mm² Single-core
  Stranding construction 56 × 0.30 mm (approx.) — Very flexible
  DC resistance @ 20 °C ≤ 4.95 Ω/km Cu 4.0 mm² flexible max
  Conductor weight per km ≈ 39 kg/km 4.0 mm² Cu
  Conductor diameter ≈ 3.0 mm Flexible
03 · Insulation
  Insulation type PVC (polyvinyl chloride) — General-purpose
  Insulation thickness ≈ 0.9 mm 450/750 V
  Finished outer diameter ≈ 4.2 mm Overall
  Insulation color Blue (shown); other colors available — Per order
04 · Electrical
  Rated voltage (U0/U) 450/750 V Building wiring
  Max voltage 750 V Phase-to-phase
  DC resistance @ 20 °C ≤ 4.95 Ω/km Flexible Cu 4.0 mm²
  Insulation resistance ≥ 20 MΩ·km PVC
  Test voltage (AC) 2.5 kV / 5 min — Routine
  Nominal current (ampacity) ≈ 32 A In conduit, 30 °C
  Voltage drop per 100 m ≈ 1.8 V/A·100m At 4.95 Ω/km
05 · Thermal
  Max conductor temp. 70 °C PVC rated
  Short-circuit temp. 160 °C Max 5 s
  Ambient range -15 ~ +70 °C Indoor
  Laying temperature ≥ 0 °C Indoor
06 · Mechanical
  Min bending radius (fixed) ≥ 2 × OD ≈ 8 mm Very flexible
  Flexibility Excellent — Class 5 fine strands
  Crush resistance Moderate — In conduit
07 · Installation
  Laying methods Conduit, trunking, panel wiring, equipment leads — Flexible wiring
  Connectors Crimp lugs / screw terminals — Standard
  Special tools Wire stripper, crimping tool — Basic
  Bend radius ≥ 2 × OD ≈ 8 mm — Very flexible
08 · Packing
  Standard supply length 100 m / coil m Building wire
  Reel / packing type Coil, wrapped — Plastic bag
  Surface marking BVR, 4.0mm², 450/750V, GB/T 5023, metre marks — Continuous printing
  Storage conditions Dry, indoor — Protect from moisture
09 · Applications
  Typical use Flexible indoor wiring, control panels, appliance connections, equipment leads — Building electrical
  Max system voltage 750 V 450/750 V
  Application level Low voltage — Indoor building
10 · Color Coding
  Red Phase L1 — Live
  Blue Neutral N — Return
  Yellow-green Earth PE — Ground
  Black Phase L2/L3 — Alternative

 

The wire test parameters

 

Test Parameters — BVR-4.0 mm² Flexible Building Wire
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 4.95 Ω/km (flexible Cu 4.0 mm²) Routine
2 Voltage test (AC) 2.5 kV AC, 5 min No breakdown Routine
3 Insulation resistance 500 V DC ≥ 20 MΩ·km Routine
4 Insulation thickness Micrometer ≥ 0.9 mm Routine
5 Heating test 70 °C conductor, 2 h No damage Type
6 Flexibility / bending test 2× OD, repeated cycles No damage Type
7 Flame retardancy IEC 60332-1 Self-extinguishing Type
8 Dimensional check Micrometer / caliper OD ≈ 4.2 mm Routine
9 Conductor continuity Per GB/T 3956 All strands continuous Routine
10 Cold bend test -15 °C, bending No cracking Type
11 Strand count Visual / microscopic ≈ 56 strands Routine
12 Printing legibility Visual Marking readable Routine

 

The wire cross section structure

 

Bvr 4.0mm2 Stranded Copper Conductor Pvc Insulated Flexible Building Wire

BVR-4.0 mm² — Cross-Section Construction Diagram (Schematic)
Flexible building wire: fine-stranded Cu conductor → PVC insulation · 450/750 V · 70 °C · finished Ø ≈ 4.2 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor Fine-stranded annealed copper, Class 5, 4.0 mm² — ≈ 3.0 R ≤ 4.95 Ω/km
2 PVC insulation Polyvinyl chloride, general-purpose ≈ 0.9 ≈ 4.2 (finished) 450/750 V rated
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 4.2 mm Overall    
Approx. cable mass ≈ 52 kg/km Flexible building wire    
Nominal voltage rating 450/750 V Indoor building    
Max conductor temp. 70 °C PVC rated    
Short-circuit temp. 160 °C Max 5 s    
Min bending radius (fixed) ≥ 2 × OD ≈ 8 mm Very flexible    
DC resistance @ 20 °C ≤ 4.95 Ω/km Flexible Cu 4.0 mm²    
Test voltage (AC) 2.5 kV / 5 min — Routine    
Nominal current (ampacity) ≈ 32 A In conduit, 30 °C    
Conductor class Class 5 (fine-stranded) — Flexible    
Conductor material Annealed copper — High conductivity    
Insulation material PVC — General-purpose    
Standard GB/T 5023 / IEC 60227 — Building wire    
Application Flexible fixed wiring — Panel / equipment leads    
Schematic — not to exact scale. Finished Ø ≈ 4.2 mm and weight ≈ 52 kg/km from cross-referenced industry samples. BVR-4.0 is the flexible version of BV-4.0 — same PVC insulation, but with a fine-stranded Class 5 copper conductor for improved flexibility. Values marked (est.) require confirmation against the factory test certificate.

 

Construction Description

 

Construction Description — BVR-4.0 mm² flexible building wire
Layer-by-layer flexible building wire: fine-stranded Cu conductor / PVC insulation · 450/750 V · 70 °C · finished Ø ≈ 4.2 mm
1. Product Identity & Ratings
BVR-4.0 is a single-core PVC insulated flexible copper building wire rated 450/750 V, 70 °C continuous. Built per GB/T 5023 / IEC 60227. It uses a Class 5 fine-stranded copper conductor (~56×0.30 mm) for superior flexibility compared to rigid BV wire. Ideal for control panels, equipment leads, and tight spaces. Finished Ø ≈ 4.2 mm, mass ≈ 52 kg/km, 100 m coils.
2. Fine-Stranded Flexible Conductor
The conductor uses 4.0 mm² fine-stranded annealed copper (Class 5, ~56 × 0.30 mm strands). The many tiny strands make the wire highly flexible and resistant to metal fatigue from repeated bending. DC resistance ≤ 4.95 Ω/km at 20 °C — slightly higher than rigid BV due to strand gaps.
3. PVC Insulation
PVC insulation ≈ 0.9 mm thick. Rated 450/750 V. Available in multiple colors: red (phase), blue (neutral), yellow-green (earth), black. The PVC provides basic electrical insulation and is self-extinguishing. Not UV-resistant — indoor use only.
4. BVR vs BV Difference
BVR = flexible wire (R = soft). BV = rigid wire. BVR uses many fine strands (Class 5) vs BV's fewer thicker strands (Class 2). BVR bends easier and resists fatigue, but has slightly higher DC resistance and costs more. Choose BVR where flexibility matters — panels, equipment, tight conduit.
5. Site Handling & Operational Notes
• Bend radius 2×OD (≈ 8 mm) — very flexible.  • Pull into conduit/trunking.  • Use wire stripper carefully — fine strands cut easily.  • Crimp lugs rated for flexible conductors.  • At 52 kg/km, lightweight.  • Indoor use only.  • Store dry.

 

 

8. Standards & Conformity. GB/T 5023 (PVC insulated cables 450/750 V); IEC 60227 (international equivalent); GB/T 3956 (Class 5 flexible conductors). Rated 450/750 V.

 

9. Packaging, Storage & Logistics. 100 m per coil, plastic wrapped. Continuous marking: BVR, 4.0mm², 450/750V, GB/T 5023, metre marks. Store dry, indoor.

 

Bvr 4.0mm2 Stranded Copper Conductor Pvc Insulated Flexible Building Wire

 

10. Procurement Specification. State "BVR-4.0, color" + length. Red = phase, blue = neutral, yellow-green = earth. Confirm against factory test certificate.

 

11. Cable Industry FAQ.

  • Q1: What is the difference between BVR and BV? BVR (R = soft) uses a Class 5 fine-stranded conductor (~56×0.30 mm) for maximum flexibility. BV uses a Class 2 stranded conductor (19×0.50 mm) for fixed rigid installation. BVR bends easier and resists fatigue, but has slightly higher DC resistance (4.95 vs 4.61 Ω/km).
  • Q2: When should I choose BVR over BV? Choose BVR where flexibility matters — control panels, equipment leads, tight conduit, repeated bending. Choose BV for straight runs in conduit where rigidity is not a problem.
  • Q3: Why is the DC resistance higher for BVR? The fine strands have small gaps between them, reducing effective copper area. This gives BVR a slightly higher resistance (4.95 vs 4.61 Ω/km for BV). The difference is small and acceptable.
  • Q4: What does "Class 5" mean? Per GB/T 3956 / IEC 60228, Class 5 is the flexible conductor class — many thin strands. Class 2 is rigid stranded; Class 1 is solid.
  • Q5: Can BVR be used outdoors? No — standard PVC insulation is not UV-resistant. Use outdoor-rated cable or conduit for exterior runs.
  • Q6: What is the ampacity of BVR-4.0? Approximately 32 A in free air at 30 °C. In conduit with multiple wires, derate to ~25 A depending on grouping.
  • Q7: What is the bending radius? 2×OD ≈ 8 mm — very flexible. Easy to route around corners in tight panels.
  • Q8: What color coding is used? Red = phase L1, blue = neutral N, yellow-green = protective earth PE, black = alternate phase.
  • Q9: Can I use BVR for fixed wall wiring? Yes — BVR can be used for any fixed indoor wiring where BV is used. The only difference is flexibility. BVR is slightly more expensive.
  • Q10: Is BVR fire-resistant? No — BVR is general-purpose PVC wire. For fire circuits, use mineral-insulated fire cables (BTTRZ/BTLY).
  • Q11: How do I terminate BVR-4.0? Use crimp lugs rated for flexible conductors (ferrule terminals). The fine strands must be fully captured in the lug to avoid stray strands and high resistance.