RVVP 2x0.75mm² Precision Low Noise Shielded Instrument Cable Braided Copper Communication 300/500V

RVVP 2x0.75mm² Precision Low Noise Shielded Instrument Cable Braided Copper Communication 300/500V

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
RVVP 2x0.75mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

RVVP 2x0.75mm² Precision Low Noise Shielded Instrument Cable Braided Copper Communication 300/500V Cable Designation & Meaning Code Meaning R Flexible cord V PVC insulation V PVC sheath P Copper braid shield 2×0.75 mm² Two cores of 0.75 mm² copper conductor Construction: Two 0.75 mm² fine-stranded ...

Product Details

Highlight:

RVVP shielded instrument cable

,

2 core braided copper cable

,

300/500V low noise cable

Conductor (×2):
Copper, Flexible (Class 5), Nominal 24×∅0.20 Mm (0.75 Mm²), Conductor Ø ≈ 1.4 Mm Per Core
Insulation:
PVC (Type TI2), Nominal Thickness 0.6 Mm, Min. Thickness 0.44 Mm
Lay-up:
Two Insulated Cores Twisted Together
Shield:
Tinned Copper Braid, Coverage ≥ 80%, Nominal 16×4/0.10 Mm
Outer sheath:
PVC (Type TM2), Nominal Thickness 0.8 Mm, Min. Thickness 0.62 Mm
Conductor nominal area:
0.75 Mm² (Cu) × 2
Number of cores:
2
Conductor material:
Copper (Cu)
Conductor class:
Class 5 Flexible
Conductor construction:
24×∅0.20 Mm Per Core
Conductor diameter:
≈ 1.4 Mm Per Core
Insulation thickness (nom.):
0.6 Mm
Insulation thickness (min.):
0.44 Mm
Shield coverage:
≥ 80%
Outer sheath thickness (nom.):
0.8 Mm
Outer sheath thickness (min.):
0.62 Mm
Overall cable diameter:
6.2 – 7.2 Mm
Design outer diameter:
≈ 6.8 Mm
Approx. weight:
55 – 70 Kg/km
Design weight:
≈ 62 Kg/km
Cable shape:
Round

Product Description

RVVP 2x0.75mm² Precision Low Noise Shielded Instrument Cable Braided Copper Communication 300/500V

Cable Designation & Meaning

Code

Meaning

R

Flexible cord

V

PVC insulation 

V

PVC sheath

P

Copper braid shield 

2×0.75 mm²

Two cores of 0.75 mm² copper conductor


Construction: Two 0.75 mm² fine-stranded copper conductors, PVC insulation on each core, laid up together, tinned copper braid shield (≥85% coverage) over the laid-up cores, PVC outer sheath.

Applicable Standards

  • GB/T 5023.5-2008 / IEC 60227-5 — Polyvinyl chloride insulated cables — Flexible cables (cords)
  • GB/T 3956-2008 / IEC 60228 — Conductors of insulated cables (Class 5 flexible)
  • GB/T 18380.3 / IEC 60332-3 — Flame retardant (Category A/B/C as specified)
  • GB/T 5023.2-2008 / IEC 60227-2 — Test methods

RVVP 2x0.75mm² Precision Low Noise Shielded Instrument Cable Braided Copper Communication 300/500V


RVVP 2×0.75 mm² — Flexible Shielded Control Cable — Specification

1. Overview & Ratings

RVVP is a flexible shielded control cable: R = flexible tinned copper conductor, V = PVC insulation, V = PVC outer sheath, P = braided copper shield. The 2×0.75 version has two 0.75 mm² cores rated 300/500 V. OD ≈ 6.8 mm, ≈ 48 kg/km (est.), ≈ 6–8 A. The tinned copper braid provides ≈ 85% coverage for EMI/RFI protection. Designed for control panels, instrumentation, signal transmission and low-voltage interconnections in industrial and automation environments. Max conductor temperature 70 °C, operating range -15 to +70 °C. Not for outdoor direct sun without UV protection, and not for mains power distribution.

2. Construction Stack (Inner → Outer, expanded)

Layer / Feature Build Function
Conductor (×2) Tinned Cu, Class 5, 24×0.20 mm per core R ≤ 26.0 Ω/km, flexible, solderable
Insulation PVC ≈ 0.6 mm per core Electrical insulation, colour-coded
Inner sheath PVC ≈ 0.5 mm Round bedding, braid substrate
Braid shield Tinned Cu, ≈ 85% coverage EMI/RFI shielding, drain path
Outer jacket PVC ≈ 0.7 mm Mechanical, oil/abrasion protection

3. Electrical Characteristics

DC resistance ≤ 26.0 Ω/km at 20 °C per GB/T 3956. Rated voltage 300/500 V. Estimated ampacity ≈ 6–8 A in free air at 30 °C. Insulation resistance ≥ 20 MΩ·km. Routine AC withstand test at 2000 V for 5 minutes. Typical capacitance ≈ 120 pF/m at 1 kHz. Characteristic impedance ≈ 100–120 Ω at high frequency. The braid shield provides ≈ 60–70 dB shielding effectiveness at 30–1000 MHz, blocking interference from VFDs, motors and welding equipment.


Insulation & Sheath Data


Property

Value

Insulation material

PVC (Type TI2)

Outer sheath material

PVC (Type TM2)

Shield material

Tinned copper braid

Long-term service temp.

70 °C (continuous)

Max. conductor temp. (normal)

70 °C

Short-circuit temp. (≤5 s)

160 °C

Emergency overload temp.

100 °C (≤1 h)

Test voltage AC (5 min)

2.0 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹² Ω·cm

Shield

Tinned copper braid, ≥ 85% coverage (EMI/RFI protection)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

300 / 300 V

GB/T 5023.5 (control/signal)

Max. system voltage

350 V AC / 500 V DC

—

Test voltage AC (5 min)

2.0 kV

Routine test

DC resistance @20 °C

≤ 26.0 Ω/km per core

GB/T 3956 Class 5 Cu max (0.75 mm²)

AC resistance @70 °C (est.)

≈ 32.5 Ω/km per core

—

Current rating in air (30 °C)

Control: 6 A per core​ (recommended max.)

conservative control rating

Current rating in tray (30 °C)

Control: 7 A per core​

—

DC current capacity

6 A​ per core

—

Short-circuit current (1 s, Cu, 160 °C)

≈ 82 A per core

—

Capacitance (core-to-core, approx.)

≈ 0.12 µF/km

PVC

Capacitance (core-to-shield, approx.)

≈ 0.20 µF/km

PVC

Inductive reactance (approx.)

≈ 0.07 Ω/km

at 50 Hz

Frequency

DC / up to 100 MHz (signal)

—

Characteristic impedance (approx.)

50 – 70 Ω

signal reference

Attenuation (at 1 MHz, approx.)

≈ 0.8 dB/100 m

—


Reference values: RVVP 2×0.75 at 6 A per core, 24 V DC → max load ≈ 144 W​ per core (control/signal use). At 230 V AC → max load ≈ 1,380 VA​ per core (not recommended for power).

4. Thermal & Flame Behaviour

Operating range -15 to +70 °C continuous. Short-circuit withstand up to 160 °C for ≤ 5 seconds. PVC insulation and jacket are flame-retardant per IEC 60332-1 single vertical flame test. The cable is halogen-containing (PVC), so it emits HCl gas on burning — not suitable for enclosed spaces where corrosive gas is a concern. For low-smoke halogen-free applications, choose RVVSP or LSZH alternatives. Oil-resistant Type ST jacket suits machine tools and industrial cabinets. UV resistance is limited; install indoors or in UV-protected conduits.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

70 °C (continuous)

Max. short-circuit temp. (≤5 s)

160 °C

Emergency overload temp.

100 °C (≤1 h)

Min. installation ambient temp.

−15 °C

Service ambient range

−15 °C to +70 °C

Flexing temp. range

−5 °C to +70 °C

Fire Performance (RVVP — PVC, Non-Low-Smoke)

Property

Value / Requirement

Flame retardant

GB/T 18380.3 / IEC 60332-3​ (Category A/B/C as specified)

Halogen content

Contains halogen​ (PVC)

Smoke density

Not low-smoke​ (IEC 61034-2 not applicable)

Corrosivity

Corrosive​ (HCl emission from PVC)

Toxicity

Toxic fumes​ when burned (CO, HCl)

EMI shielding

Excellent​ (tinned copper braid, ≥85% coverage)

UV resistance

Poor​ (PVC degrades outdoors, use conduit or UV-resistant)

Water resistance

Limited​ (PVC sheath)

5. Installation Practice & Handling

Minimum bending radius ≥ 6×OD ≈ 41 mm for fixed installation; 12×OD for moving or drag-chain applications. When terminating, connect the braid shield to earth at one end (or both ends per system design) using a shield drain wire or gland. Do not over-tighten cable glands, which would crush the braid. Use appropriate ferrules on the fine Class 5 strands. Route the cable away from high-power motor cables by at least 200 mm, or use separate metal conduits for the shielded signal pair. After installation, verify insulation resistance and shield continuity before energizing.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 6 × OD → ≈ 41 mm at Ø6.8 mm

flexible cable

Max. pulling tension

11 N per core (0.75 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Not recommended​ (PVC, non-UV, water ingress)

—

Surface mounting

Cable tray, conduit, trunking, DIN rail

—

Conduit ID

≥ 16 mm

—

Fixing

cable ties, clamps, clips

—

Impact resistance

Low (PVC)

—

Water resistance

Limited​ (PVC sheath)

—

UV resistance

Poor​ (indoor/conduit only)

—

Flex life

Excellent​ (Class 5 fine-stranded)

flexible routing

Termination note

Screw terminals, IDC connectors, D-sub, RJ45 (via adapter)

—

6. Typical Service Applications

Control panels and PLC I/O wiring, instrumentation and sensor signals (4–20 mA, 0–10 V), relay and contactor control circuits, interconnection between switches and contactors, low-voltage alarm circuits, and audio/signal interconnections in industrial environments. Particularly suitable near variable-frequency drives (VFDs), servo motors, welding equipment and other noise sources, where the braid shield suppresses electromagnetic interference. Not for: mains AC power distribution, high-speed data bus (use profibus/FlexRay), direct burial, or outdoor UV-exposed runs.


RVVP 2x0.75mm² Precision Low Noise Shielded Instrument Cable Braided Copper Communication 300/500V

7. Testing & Quality Assurance Regime

Routine tests (100% production): DC resistance, AC voltage withstand (2000 V/5 min), insulation resistance, conductor construction, wall thickness, dimensional check, print legibility, mass per length, visual appearance, and packing. Type tests (per batch / material change): shield coverage, heat aging (100 °C/7 days), cold bend (-15 °C), jacket tensile, flame retardancy, and shielding effectiveness measurement. Every coil ships with mill test certificate, ROHS and REACH declarations. The in-house lab is calibrated annually against national standards.


Cable Parameters


RVVP 2×0.75 mm² — Full Parameter Sheet
Shielded flexible control cable · 300/500 V · tinned Cu Class 5 · PVC insulation/jacket · tinned Cu braid ≈ 85% · GB/T 9330 / IEC 60227
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type RVVP — Flexible tinned Cu, PVC ins., PVC jacket, braid shield

Rated voltage (U0/U) 300/500 V Control / signal circuits

Number of cores 2 — 2 cores, colour-coded

Nominal cross-section 0.75 mm² Per core, Class 5 flexible

Conductor material Tinned annealed copper — Class 5 per GB/T 3956 / IEC 60228

Insulation material PVC (Type SP) — 70 °C rated

Shield Tinned copper braid — ≈ 85% coverage

Outer jacket material PVC (Type ST) — Oil/abrasion resistant

Standard reference GB/T 9330 / IEC 60227 / UL 2464 — Harmonized control cable
02 · Conductor

Stranding 24 × 0.20 mm — Class 5 tinned copper per core

Conductor diameter ≈ 1.05 mm Per core, strand-lay

DC resistance @ 20 °C ≤ 26.0 Ω/km Maximum per GB/T 3956

Conductor surface Tinned — Anti-corrosion, solderable
03 · Insulation

Insulation type PVC (Type SP) — Soft PVC, 70 °C

Insulation thickness ≈ 0.6 mm Nominal

Insulated core Ø ≈ 2.25 mm Per core

Insulation resistance ≥ 20 MΩ·km At 20 °C
04 · Shield & Inner Sheath

Inner sheath material PVC — Bedding over laid-up cores

Inner sheath thickness ≈ 0.5 mm Nominal

Shield type Tinned Cu braid — Woven over inner sheath

Shield coverage ≈ 85 % Typical

Shielding effectiveness ≈ 60–70 dB At 30–1000 MHz
05 · Outer Jacket

Jacket material PVC (Type ST) — Oil/abrasion resistant

Jacket thickness ≈ 0.7 mm Nominal

Overall finished diameter ≈ 6.8 mm 2-core shielded

Approximate cable mass ≈ 48 kg/km Tinned Cu + PVC + braid

Mass per 100 m ≈ 4.8 kg/100 m For coil loading
06 · Electrical

Rated voltage 300/500 V Control circuits

Test voltage (AC) 2000 V AC 5 min routine

DC resistance @ 20 °C ≤ 26.0 Ω/km Per GB/T 3956

Ampacity (free air) ≈ 6–8 A 0.75 mm², 70 °C

Capacitance (core-core) ≈ 120 pF/m At 1 kHz

Characteristic impedance ≈ 100–120 Ω At high frequency
07 · Thermal & Mechanical

Max continuous conductor temp. 70 °C Normal service

Short-circuit temp. (≤5 s) 160 °C Copper limit

Min. ambient temp. -15 °C Fixed installation

Min. bending radius ≥ 6 × OD ≈ 41 mm Fixed; 12× for moving

Halogen content Halogen-containing — PVC compound
08 · Flame & Environment

Flame retardancy IEC 60332-1 — Single vertical flame

Oil resistance Good — Type ST PVC

UV resistance Limited — Indoor / conduit use

ROHS / REACH Compliant — EU 2011/65/EU


Cable Test Parameters


Test Parameters — RVVP 2×0.75 mm²
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 26.0 Ω/km Routine
2 AC voltage withstand 2000 V AC, 5 min No breakdown Routine
3 Insulation resistance 500 V megohmmeter ≥ 20 MΩ·km Routine
4 Conductor construction Visual + strand count 24 × 0.20 mm tinned Cu Routine
5 Wall thickness Micrometer cross-section Ins. ≈ 0.6 mm; jacket ≈ 0.7 mm Routine
6 Dimensional check Caliper OD ≈ 6.8 mm Routine
7 Print legibility Visual + rubbing Marks legible Routine
8 Mass per unit length Weighing ≈ 48 kg/km Routine
9 Appearance Visual Smooth, no blisters Routine
10 Packing Visual Coil/drum, sealed ends, labelled Routine
11 Shield coverage Unwrap + count ≥ 80% (≈ 85%) Type
12 Heat aging test 7 days at 100 °C Retention ≥ 70% Type
13 Cold bend test -15 °C, 4 h mandrel No cracking Type
14 Jacket tensile test Universal tester Meets GB/T 9330 min. Type
15 Flame retardancy IEC 60332-1 Self-extinguish Type
16 Shielding effectiveness Triaxial / open-field ≥ 60 dB at 30–1000 MHz Type


Cable Cross Section Structure

RVVP 2x0.75mm² Precision Low Noise Shielded Instrument Cable Braided Copper Communication 300/500V

RVVP 2×0.75 mm² — Cross-Section Construction Diagram (Schematic)
Layered build-up: tinned Cu Class 5 conductors → PVC insulation → inner PVC sheath → tinned copper braid shield → PVC outer jacket · 300/500 V shielded control cable · signal transmission · EMI/RFI protection · -15~+70 °C
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (×2) Tinned annealed copper, Class 5 flexible — 24 × 0.20 mm strands per core — ≈ 1.05 (per core) Signal/power carrying; R ≤ 26.0 Ω/km; tinned for anti-corrosion and solderability
2 Insulation (per core) PVC compound (Type SP), extruded over each conductor, colour-coded ≈ 0.6 ≈ 2.25 (per insulated core) Electrical insulation; 300/500 V rated; colour-coded (red/black, blue/white, etc.)
3 Inner sheath PVC compound, extruded over the two laid-up cores, round filler ≈ 0.5 ≈ 5.0 (before braid) Round and bed the cores; mechanical protection; bedding for braid
4 Braid shield Tinned copper wire braid, ≈ 85% coverage, laid over inner sheath ≈ 0.35 (effective) ≈ 5.7 EMI/RFI shielding; drain path for fault currents; low transfer impedance
5 Outer jacket PVC compound (Type ST), black or grey, extruded over braid ≈ 0.7 ≈ 6.8 (finished) Outer mechanical protection; oil-, UV- and abrasion-resistant; printed markings






Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 6.8 mm 2-core shielded control cable (est.)
Approximate cable mass ≈ 48 kg/km Tinned Cu + PVC + braid build-up
Nominal voltage rating 300/500 V Control / signal circuits
Max continuous conductor temp. 70 °C Normal service
Min. ambient / installation temp. -15 °C Fixed installation
DC resistance @ 20 °C ≤ 26.0 Ω/km Class 5 tinned copper, EN 60228
Core count × cross-section 2 × 0.75 mm² 2 cores
Shield coverage ≈ 85 % Tinned copper braid
Insulation resistance ≥ 20 MΩ·km PVC at 20 °C
Test voltage (AC) 2000 V AC / 5 min — Routine withstand test
Flame retardancy IEC 60332-1 — Single vertical flame
Shielding effectiveness ≈ 60–70 dB — At 30–1000 MHz
Jacket colour Black / grey / custom — Standard: black
Mass per 100 m ≈ 4.8 kg/100 m For coil / drum loading
Reference standard GB/T 9330 / IEC 60227 / UL 2464 — Harmonized control cable
Schematic — not to exact scale. Finished Ø ≈ 6.8 mm and weight ≈ 48 kg/km from cross-referenced industry samples; conductor stranding 24/0.20 mm per core and braid coverage ≈ 85%. Est. values confirmed against factory type certificate.

Construction Description

Construction Description — RVVP 2×0.75 mm²
Layer-by-layer build-up narrative · 300/500 V shielded control cable · GB/T 9330 / IEC 60227 · tinned copper / PVC insulation / tinned copper braid shield / PVC outer jacket
1. Product Identity & Ratings
RVVP is a Chinese-designation flexible shielded control cable: R = flexible copper conductor, V = PVC insulation, V = PVC outer sheath, P = braided shield. The 2×0.75 version has two 0.75 mm² cores rated 300/500 V. It is built for control and signal circuits where electromagnetic interference must be suppressed. Max conductor temperature 70 °C, operating range -15 to +70 °C. Not for outdoor direct sun without UV protection, and not for mains power distribution.
2. Tinned Copper Conductor (×2)
Each 0.75 mm² core is stranded from 24 tinned annealed copper wires of 0.20 mm in a Class 5 flexible lay-up. The fine stranding gives high flexibility for repeated motion in drag chains and panel wiring. Tinning improves solderability and resists oxidation. Max DC resistance is 26.0 Ω/km at 20 °C per GB/T 3956. Two cores are laid up together, colour-coded for identification (red/black, blue/white).
3. PVC Insulation
Each conductor is extruded with a layer of PVC insulation approximately 0.6 mm thick. The insulation compound is Type SP (soft PVC) formulated for 70 °C continuous service. The insulation provides the primary electrical barrier between the two cores and between cores and earth. Colour coding ensures correct polarity in control panels. Insulation resistance is ≥ 20 MΩ·km at 20 °C.
4. Inner Sheath + Braid Shield
The two insulated cores are laid up with round fillers to form a round cable, then bedded with a 0.5 mm PVC inner sheath. Over this, a tinned copper wire braid is woven at approximately 85% coverage. The braid provides EMI/RFI shielding by diverting interference currents to earth through the shield drain. The shield coverage yields roughly 60–70 dB attenuation at 30–1000 MHz.
5. Outer PVC Jacket
A final 0.7 mm PVC jacket (Type ST) is extruded over the braid, giving the finished cable an outer diameter of approximately 6.8 mm. The jacket is typically black or grey, oil-resistant, abrasion-resistant and flame-retardant. Printed markings along the jacket show product type, cross-section, voltage rating, metre marking and manufacturer name. Install in dry indoor areas or UV-protected conduits.

8. Factory Advantages

Tinned copper conductor for oxidation resistance and easy soldering. Tinned copper braid shield at ≈ 85% coverage for reliable EMI/RFI protection. Flexible Class 5 stranding dresses easily in control panels and drag chains. Colour-coded cores (red/black) prevent wiring errors. Oil-resistant PVC jacket for industrial cabinet use. 100% routine electrical QA on every production reel. Cut-to-length on coils with sealed ends for reduced waste. Lightweight ≈ 48 kg/km for easy handling. Full traceability from copper rod to finished reel, with MTC and certification support for industrial tenders.


RVVP 2x0.75mm² Precision Low Noise Shielded Instrument Cable Braided Copper Communication 300/500V

9. Packaging, Storage & Logistics

Cut to customer-specified length on export-grade coils or wooden drums, with both ends heat-sealed to prevent moisture ingress. Coils wrapped in waterproof film and corrugated cardboard, labelled with product type, core count, cross-section, length, weight, production date and reel number. Standard lengths 100/200/500/1000 m. Store dry indoor, -10 to +40 °C, below 75% RH, away from direct sunlight and chemical solvents. FOB Shanghai/Nanjing/Qingdao; CIF and DAP available. Sample lead time 5–7 days; bulk production 15–25 days.


RVVP 2x0.75mm² Precision Low Noise Shielded Instrument Cable Braided Copper Communication 300/500V

10. Procurement Specification

State cable designation "RVVP 2×0.75", required length per coil/drum, and core colour preference (red/black, blue/white, etc.). Request the routine AC withstand test record and shield coverage certificate for the specific batch. Specify any regional certification requirements (UL 2464, CE, etc.) at order time. Payment: 30% T/T deposit, balance against B/L copy. Documents: MTC, ROHS/REACH, COO, commercial invoice, packing list. For drag-chain or continuous-flex applications, specify RVVSP (flexible braid) variant instead.

11. Cable Industry FAQ

Q1: What does RVVP mean? R = flexible copper, V = PVC insulation, V = PVC jacket, P = braided shield. It is a shielded flexible control cable.

Q2: Why a braid shield? The tinned copper braid blocks EMI/RFI from motors, VFDs and welding equipment, preventing signal noise.

Q3: What voltage? 300/500 V for control and signal circuits.

Q4: Is it UV resistant? Limited — use indoors or in UV-protected conduits only.

Q5: DC resistance? ≤ 26.0 Ω/km at 20 °C for 0.75 mm² Class 5 tinned copper.

Q6: Current rating? ≈ 6–8 A in free air; derate in bundles.

Q7: How to ground the shield? Connect braid to earth at one end (or both ends per system design) using a drain wire or shield gland.

Q8: Halogen-free? No — PVC is halogen-containing. Use LSZH for enclosed spaces.

Q9: Temperature range? -15 to +70 °C continuous.

Q10: Packing? Coils or drums with sealed ends, cut to length.

Q11: What proof ships? Routine AC test record + shield coverage certificate + MTC.