RVVP 2x0.75mm² Precision Low Noise Shielded Instrument Cable Braided Copper Communication 300/500V
RVVP 2x0.75mm² Precision Low Noise Shielded Instrument Cable Braided Copper Communication 300/500V
Tóm tắt sản phẩm
RVVP 2x0.75mm² Precision Low Noise Shielded Instrument Cable Braided Copper Communication 300/500V Cable Designation & Meaning Code Meaning R Flexible cord V PVC insulation V PVC sheath P Copper braid shield 2×0.75 mm² Two cores of 0.75 mm² copper conductor Construction : Two 0.75 mm² fine-stranded ...
Chi tiết sản phẩm
Làm nổi bật:
RVVP shielded instrument cable
,2 core braided copper cable
,300/500V low noise cable
Conductor (×2):
Đồng, dẻo (Loại 5), danh nghĩa 24×∅0,20 mm (0,75 mm²), dây dẫn Ø ≈ 1,4 mm mỗi lõi
Insulation:
PVC (Loại TI2), độ dày danh nghĩa 0,6 mm, tối thiểu. độ dày 0,44 mm
Lay-up:
Hai lõi cách điện xoắn vào nhau
Shield:
Bện đồng mạ thiếc, độ che phủ ≥ 80%, danh nghĩa 16×4/0,10 mm
Outer sheath:
PVC (Loại TM2), độ dày danh nghĩa 0,8 mm, tối thiểu. độ dày 0,62 mm
Conductor nominal area:
0,75 mm² (Cu) × 2
Number of cores:
2
Conductor material:
Đồng (Cu)
Conductor class:
Lớp 5 linh hoạt
Conductor construction:
24×∅0,20 mm mỗi lõi
Conductor diameter:
≈ 1,4 mm mỗi lõi
Insulation thickness (nom.):
0,6 mm
Insulation thickness (min.):
0,44mm
Shield coverage:
≥ 80%
Outer sheath thickness (nom.):
0,8 mm
Outer sheath thickness (min.):
0,62mm
Overall cable diameter:
6,2 – 7,2 mm
Design outer diameter:
≈ 6,8 mm
Approx. weight:
55 – 70 kg/km
Design weight:
≈ 62kg/km
Cable shape:
Tròn
Mô tả sản phẩm
RVVP 2x0.75mm² Precision Low Noise Shielded Instrument Cable Braided Copper Communication 300/500V Cable Designation & Meaning Code Meaning R Flexible cord V PVC insulation V PVC sheath P Copper braid shield 2×0.75 mm² Two cores of 0.75 mm² copper conductor Construction : Two 0.75 mm² fine-stranded copper conductors, PVC insulation on each core, laid up together, tinned copper braid shield (≥85% coverage) over the laid-up cores, PVC outer sheath. Applicable Standards GB/T