"bttrz fire substation cable"
Please try a different search term or browse our product categories.
Fil noir BV 2,5 mm2 en cuivre massif Cu PVC pour l'installation de conduits
Black BV 2.5mm² Solid Copper Conductor PVC Wire for Conduit Installation Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or ...
Fil de cuivre monoconducteur isolé PVC, conducteur en cuivre massif rouge
Red BV 2.5mm² PVC Insulated Single Core Copper Live Wire 450/750V Electrical Building Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper ...
1.0mm2 Conducteur de cuivre solide anneulé 18 Awg Fil de cuivre nu
BV 1.0 mm² / 18 AWG — Technical Specification Category Parameter Value / Description Product Identity Model Number BV (equivalent to 60227 IEC 01 / IEC 05) Product Name Copper Conductor PVC Insulated Single-Core Building Wire Standards Compliance GB/T 5023.3-2008, JB/T 8734.2-2016 Certification CCC ...
8.7KV 10kV Mv câble électrique gratte-ciel blindé câble principal en aluminium
Skyscraper Main Aluminum Cable YJLV22 3x400mm2 8.7/10kV 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 ...
Cable Mv neutre concentrique en aluminium 3x95mm2 3 cœurs câble blindé en aluminium
Main Distribution Aluminum Cable YJLV22 3x95mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
Super lourd câble MV YJV22 3x300mm2 8.7/15kV câble d'alimentation XLPE blindé
Super Heavy MV Cable YJV22 3x300mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
Cable électrique à haute tension YJV22 3x150mm2 8.7/15kV câble blindé XLPE
Heavy Gauge MV Cable YJV22 3x150mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
4x185mm2 + 1x150mm2 câble ignifuge 0.6KV 1KV câble minéral isolé en cuivre
Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...