"bttrz fire substation cable"
Please try a different search term or browse our product categories.
लाल ठोस तांबा कंडक्टर पीवीसी अछूता एकल कोर तांबा लाइव तार
Red BV 2.5mm² PVC Insulated Single Core Copper Live Wire 450/750V Electrical Building Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper ...
1500 वी सौर पीवी केबल हलोजन मुक्त वर्ग 5 लचीला पीवी फोटोवोल्टिक तार
H1Z2Z2-K 6.0mm² TUV 1500V DC Solar Main Cable UV Resistant PV Photovoltaic Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) ...
सिंगल कोर फोटोवोल्टिक सोलर केबल 6.0mm2 TUV Xlpe Cu केबल
1500V DC Solar Wire PV1-F 6.0mm² TUV XLPE Copper Photovoltaic Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, halogen...
आईईसी 62930 सौर तार टिनयुक्त तांबा 0.095 किग्रा/एम सौर पैनलों के लिए पीवी तार
PV Cable PV1-F 6.0mm² TUV 1500V DC Low Smoke Halogen Free Solar Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, ...
सौर मुख्य केबल PV1-F 6.0mm2 TUV 1500V DC भारी शुल्क PV फोटोवोल्टिक तार
Solar Main Cable PV1-F 6.0mm² TUV 1500V DC Heavy Duty PV Photovoltaic Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
उच्च क्षमता Mv बख्तरबंद केबल 150mm2 XLPE 3 कोर एल्यूमीनियम केबल
High Capacity Aluminum Cable 3 Core 150mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
3 कोर बख्तरबंद एमवी केबल YJV22 3x50mm2 8.7/10kV 8.7/15kV XLPE पावर केबल
3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
4x185mm2+1x150mm2 अग्नि प्रतिरोधी केबल 0.6KV 1KV खनिज अछूता तांबा केबल
Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...