"bttrz fire substation cable"
Please try a different search term or browse our product categories.
سیم ساختمان مس سفید با عایق PVC، کابل برق خانگی تک رشته
BV 2.5mm2 White PVC Insulated Single Core Copper Building Wire 450/750V Household Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain ...
4.0mm2 کابل خورشیدی TUV سیم خورشیدی 1500V غیر خوردنی
H1Z2Z2-K 4.0mm² TUV Certified Solar Cable 1500V DC Photovoltaic Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen...
کابل اتصال پانل خورشیدی PV1-F 4.0mm2 TUV 1500V DC سیم PV ضد آب و هوا
Solar Panel Connection Cable PV1-F 4.0mm² TUV 1500V DC Weatherproof PV Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor...
کابل آلومینیومی XLPE YJLV22 3x70mm² 8.7/15kV کابل برق فشار متوسط زره دار
Aluminum XLPE Cable YJLV22 3x70mm² 8.7/15kV Armored MV Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
کابل فوق سنگین MV YJV22 3x185mm2 8.7/15kV کابل برق زرهی XLPE
Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
کابل MV با ظرفیت بالا YJV22 3x95mm2 8.7/15kV کابل برق زرهی XLPE
High Capacity MV Cable YJV22 3x95mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
کابل نسوز 4x185 میلی متر مربع + 1x150 میلی متر مربع 0.6 کیلو ولت 1 کیلو ولت کابل مسی عایق معدنی
Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
کابل مقاوم در برابر آتش 4+1 هسته 120 میلی متر مربع + 1x95 میلی متر مربع BTTRZ کابل زیر ایستگاه آتش
Fire Substation Cable 4+1 Core 120mm²+1x95mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6...