logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us
Search Results For:

"pvc fine strand copper wire"

- 89 Items Found
Quality PV String Cable PV1-F 4.0mm² TUV 1500V DC UV Resistant Solar Array Wire factory

PV String Cable PV1-F 4.0mm² TUV 1500V DC UV Resistant Solar Array Wire

PV String Cable PV1-F 4.0mm² TUV 1500V DC UV Resistant Solar Array Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...

Quality 1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power factory

1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power

ZR-YJV 1*70mm² Single Conductor , 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Building Power Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×70 mm² Single core, 70 mm² copper conductor ...

Quality ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation factory

ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation

ZR-YJV 1*300mm² Flame Retardant Single Core Cable, 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×300 mm² Single core, 300 ...

Quality Power 4 Core Flexible Cable 2 Core 6.0mm2 RVV For Water Heater Circuit factory

Power 4 Core Flexible Cable 2 Core 6.0mm2 RVV For Water Heater Circuit

Flexible Power Cable 2 Core 6.0mm² RVV-2*6.0mm² for Water Heater Circuit Cable Designation & Meaning Code Meaning R Flexible conductor V PVC insulation V PVC sheath 2×6.0 mm² Two cores of 6.0 mm² copper conductor Construction : Two 6.0 mm² fine-stranded copper conductors, PVC insulation on each core...

Quality OEM 4 Core Flexible Cable 4x10mm2+1x6mm2 RVV For Three Phase Earth Power Supply factory

OEM 4 Core Flexible Cable 4x10mm2+1x6mm2 RVV For Three Phase Earth Power Supply

4 Core + Earth Cable 4x10mm²+1x6mm² RVV for Three Phase + Earth Supply Cable Designation & Meaning Code Meaning R Flexible conductor V PVC insulation V PVC sheath 4×10 mm² Four cores of 10 mm² copper conductor (typically 3×L + 1×N) +1×6 mm² One core of 6 mm² copper conductor (typically reduced ...

Quality 5 Core Multi Core Control Cable 0.75mm2 RVV For Building Automation factory

5 Core Multi Core Control Cable 0.75mm2 RVV For Building Automation

Multi Core Control Cable 5 Core 0.75mm² RVV for Building Automation Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 5×0.75 mm² Five flexible cores, each 0.75 mm² copper ...

Quality Fire Alarm Multi Core Cable 5 Core 1.5m2 RVV For Emergency System factory

Fire Alarm Multi Core Cable 5 Core 1.5m2 RVV For Emergency System

Fire Alarm Multi Core Cable 5 Core 1.5mm² RVV for Emergency System Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 5×1.5 mm² Five flexible cores, each 1.5 mm² copper ...

Quality RVVP 3x1.0mm² Braided Shielded Control Cable Anti-interference for Electromagnetic Actuators factory

RVVP 3x1.0mm² Braided Shielded Control Cable Anti-interference for Electromagnetic Actuators

RVVP 3x1.0mm² Braided Shielded Control Cable Anti-interference for Electromagnetic Actuators Cable Designation & Meaning Code Meaning R Flexible cord V PVC insulation V PVC sheath P Copper braid shield 3×1.0 mm² Three cores of 1.0 mm² copper conductor Construction : Three 1.0 mm² fine-stranded ...

Quality RVVP 4x0.75mm² Shielded Control Cable Multi-Core Anti-Interference Signal Cable for Security and Building Automation factory

RVVP 4x0.75mm² Shielded Control Cable Multi-Core Anti-Interference Signal Cable for Security and Building Automation

RVVP 4x0.75mm² Shielded Control Cable Multi-Core Anti-Interference Signal Cable for Security and Building Automation Cable Designation & Meaning Code Meaning R Flexible cord V PVC insulation V PVC sheath P Copper braid shield 4×0.75 mm² Four cores of 0.75 mm² copper conductor Construction : Four 0...

Prev 6 7 8 9 10 Next