"pvc or pe low voltage power cord low voltage power cable"
Please try a different search term or browse our product categories.
سلك نحاسي صلب أحمر معزول بـ PVC أحادي النواة سلك نحاسي حي
Red BV 2.5mm² PVC Insulated Single Core Copper Live Wire 450/750V Electrical Building Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper ...
كابل شمسي من النحاس الصناعي الصناعي للطاقة الشمسية
Solar Panel Cable H1Z2Z2-K 4.0mm² TUV 1500V DC UV Resistant PV Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen...
كابل كهروضوئي نحاسي XLPE من DC Solar Wire PV1-F 4.0 مم² TUV 1500V
DC Solar Wire PV1-F 4.0mm² TUV 1500V Copper XLPE Photovoltaic Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
?
Photovoltaic Cable 4.0mm2 PV1-F TUV DC Solar Panel Connection Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
3x400mm2 كابل الجهد المتوسط XLPE سلك XLPE مدرع 26KV 35kV
YJLV22 3x400mm² Aluminum XLPE Armored HV Cable 26/35kV for Urban Power Distribution Cable Designation & Meaning Code Meaning 26/35 kV Rated voltage: U₀ = 26 kV (phase-to-earth), U = 35 kV (phase-to-phase) YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC ...
موصل الألومنيوم XLPE كابل 3 النواة 25mm2 YJLV22 8.7/10kV مدرعة
Aluminum Conductor XLPE Cable 3 Core 25mm² YJLV22 8.7/10kV Armored Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
كابل MV الثقيل للغاية YJV22 3x185mm2 8.7/15kV كابل طاقة XLPE مدرع
Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
كابل مقاوم للحريق 4x70 مم2 + 1x50 مم2 1 كيلو فولت 1.2 كيلو فولت كابل معدني معزول نحاسي عاري
Heavy Duty Fire Cable BTTRZ 4x70mm²+1x50mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...