كابل 4 النوى
كابل طاقة نحاسي معزول XLPE رباعي النواة محمي ZR-YJV 4x300 مم2 لنقل الطاقة
XLPE Insulated Flame Retardant Copper Cable ZR-YJV 4*300mm² for Power Transmission Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
موصل النحاس 4 قلوب كابل ZR-YJV 4x240mm2 كابل مضاد للنار للصناعة
Copper Conductor ZR-YJV 4*240mm² Flame Retardant Cable for Industrial Wiring Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains ...
ZR-YJV 4 كابلات كهربائية 4x185mm2 مقاومة للنار
ZR-YJV 4*185mm² Flame Retardant 4 Core Copper Power Distribution Cable Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen ...
كابل نحاس 4 أسلاك 3x10 مم² + 1x6 مم² لأسلاك الطاقة ثلاثية الطور
3+1 Core ZR-YJV Flame Retardant Copper Cable 3x10mm²+1x6mm² for Three Phase Power Wiring Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...
كابل Xlpe النحاس OEM 4 النواة مقاومة للحرارة المرنة 3 × 50mm2 + 1 × 25mm2 للخدمات الثقيلة
Flame Retardant Copper Conductor ZR-YJV 3×50mm²+1×25mm² for Heavy-Duty Three Phase Supply Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...
التيار المنخفض 4 قلوب كابل ZR-YJV 3 × 35mm2 + 1 × 16mm2 كابل XLPE
Low Voltage Flame Retardant ZR-YJV 3×35mm²+1×16mm² XLPE Cable for Mobile Power Distribution Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...
3x25mm2 + 1x16mm2 25 مربع ملم 4 كابل الأساس لمشاريع إعادة التجديد ثلاثية المراحل
Flame Retardant 3+1 Core Copper Cable ZR-YJV 3x25mm²+1x16mm² for Three Phase Retrofit Projects Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC ...
كابل لهب مثبط 3+1 أساسي 4 أسلاك للمصنع طاقة رئيسية ثلاثية الطور
ZR-YJV 3+1 Core Flame Retardant Copper Cable 3x16mm²+1x10mm² for Factory Three-Phase Main Power Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC ...
كابل الطاقة النحاسي 4 Core ZR-YJV 3 × 150mm2 + 1 × 70mm2 لنظام الطاقة
Flame Retardant Copper Cable ZR-YJV 3×150mm²+1×70mm² for Commercial Building Power System Technical Datasheet — ZR-YJV 0.6/1 kV 3×150+1×70 mm² Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE ...