"low voltage power cable low voltage power cord"
Please try a different search term or browse our product categories.
1.0mm2 موصل النحاس الصلبة 18 Awg سلك النحاس العاري
BV 1.0 mm² / 18 AWG — Technical Specification Category Parameter Value / Description Product Identity Model Number BV (equivalent to 60227 IEC 01 / IEC 05) Product Name Copper Conductor PVC Insulated Single-Core Building Wire Standards Compliance GB/T 5023.3-2008, JB/T 8734.2-2016 Certification CCC ...
كابل طاقة شمسية XLPE نحاسي شديد التحمل 6.0 مم مربع
Heavy Duty PV Wire H1Z2Z2-K 6.0mm² TUV 1500V DC XLPE Copper Solar Cable Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z ...
?
Solar Panel Connection Cable PV1-F 4.0mm² TUV 1500V DC Weatherproof PV Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor...
8.7 كيلو فولت 10 كيلو فولت كابل كهرباء سحاب مدرع كابل ألومنيوم رئيسي
Skyscraper Main Aluminum Cable YJLV22 3x400mm2 8.7/10kV 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 ...
كابل طاقة متوسط الجهد أساسي 3 موصلات شديد التحمل 185 مم2 مدرع XLPE
Heavy Duty Aluminum Cable 3 Core 185mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
3x120mm2 كابل طاقة الجهد المتوسط 8.7kV 15kV كابل الألومنيوم Mc
Industrial Main Aluminum Cable YJLV22 3x120mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated ...
كابل MV الثقيل للغاية YJV22 3x185mm2 8.7/15kV كابل طاقة XLPE مدرع
Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
4+1 كابل مقاوم للنار من النواة 120mm2+1x95mm2 BTTRZ كابل المحطة الفرعية للنار
Fire Substation Cable 4+1 Core 120mm²+1x95mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6...