"mineral fire resistant cable"
Please try a different search term or browse our product categories.
Cable unipolar de PVC y cobre amarillo 450v 750V para control de iluminación
Yellow BV 2.5mm² PVC Copper Single Core Switch Wire 450/750V Lighting Control Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor ...
Cable solar fotovoltaico de núcleo único de 6,0 mm2 TUV Xlpe Cu
1500V DC Solar Wire PV1-F 6.0mm² TUV XLPE Copper Photovoltaic Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, halogen...
Cable solar IEC 62930 de cobre estañado 0,095 kg/m para paneles solares
PV Cable PV1-F 6.0mm² TUV 1500V DC Low Smoke Halogen Free Solar Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, ...
Cable para strings fotovoltaicos PV1-F de 4.0mm² TUV 1500V DC resistente a UV para cableado de paneles solares
PV String Cable PV1-F 4.0mm² TUV 1500V DC UV Resistant Solar Array Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
3x240mm2 Cable de tensión media flexible 8.7kV 15kV 3 núcleo de cable
XLPE Medium Voltage Aluminum Cable YJLV22 3x240mm2 8.7/15kV Armored 3 Core Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 ...
Cabo de energía principal del centro de transporte YJV22 3x240mm2 8.7/15kV MV XLPE blindado
Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
Cable principal industrial mega YJV22 3x120mm² 8.7/15kV blindado MV XLPE
Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; U...
Cable ignífugo BTTRZ de 50 mm2 + 1x25 mm2 para emergencia de energía con revestimiento de cobre
BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire/power cable) T Copper conductor (Tong = copper) T Copper sheath (Tong = copper) R Flexible (Rou = flexible) Z Heavy ...