RVVP 2x4.0mm² Braided Copper Shielded Servo Motor Power Cable High Load EMI Protection 300/500V

RVVP 2x4.0mm² Braided Copper Shielded Servo Motor Power Cable High Load EMI Protection 300/500V

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
RVVP 2x4.0mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

RVVP 2x4.0mm² Braided Copper Shielded Servo Motor Power Cable High Load EMI Protection 300/500V Cable Designation & Meaning Code Meaning R Flexible cord V PVC insulation V PVC sheath P Copper braid shield 2×4.0 mm² Two cores of 4.0 mm² copper conductor Construction: Two 4.0 mm² fine-stranded copper ...

Product Details

Highlight:

RVVP 2x4.0mm² shielded power cable

,

braided copper EMI protection cable

,

300/500V servo motor cable

Conductor (×2):
Copper, Flexible (Class 5), Nominal 56×∅0.30 Mm (4.0 Mm²), Conductor Ø ≈ 3.2 Mm Per Core
Insulation:
PVC (Type TI2), Nominal Thickness 0.8 Mm, Min. Thickness 0.62 Mm
Lay-up:
Two Insulated Cores Twisted Together
Shield:
Pure Copper Braid, Coverage ≥ 80%, Nominal 16×6/0.10 Mm
Outer sheath:
PVC (Type TM2), Nominal Thickness 1.1 Mm, Min. Thickness 0.84 Mm
Conductor nominal area:
4.0 Mm² (Cu) × 2
Number of cores:
2
Conductor material:
Copper (Cu)
Conductor class:
Class 5 Flexible
Conductor construction:
56×∅0.30 Mm Per Core
Conductor diameter:
≈ 3.2 Mm Per Core
Insulation thickness (nom.):
0.8 Mm
Insulation thickness (min.):
0.62 Mm
Shield coverage:
≥ 80%
Outer sheath thickness (nom.):
1.1 Mm
Outer sheath thickness (min.):
0.84 Mm
Overall cable diameter:
10.5 – 12.0 Mm
Design outer diameter:
≈ 11.2 Mm
Approx. weight:
185 – 230 Kg/km
Design weight:
≈ 208 Kg/km
Cable shape:
Round

Product Description

RVVP 2x4.0mm² Braided Copper Shielded Servo Motor Power Cable High Load EMI Protection 300/500V

Cable Designation & Meaning

Code

Meaning

R

Flexible cord 

V

PVC insulation 

V

PVC sheath 

P

Copper braid shield 

2×4.0 mm²

Two cores of 4.0 mm² copper conductor


Construction: Two 4.0 mm² fine-stranded copper conductors, PVC insulation on each core, laid up together, tinned copper braid shield (≥80% coverage) over the laid-up cores, PVC outer sheath.

Applicable Standards

  • GB/T 5023.5-2008 / IEC 60227-5 — Polyvinyl chloride insulated cables — Flexible cables (cords)
  • GB/T 3956-2008 / IEC 60228 — Conductors of insulated cables (Class 5 flexible)
  • GB/T 18380.3 / IEC 60332-3 — Flame retardant (Category A/B/C as specified)
  • GB/T 5023.2-2008 / IEC 60227-2 — Test methods

RVVP 2x4.0mm² Braided Copper Shielded Servo Motor Power Cable High Load EMI Protection 300/500V

RVVP 2×4.0 mm² — Flexible Shielded Power Cable

1. Overview & Ratings

RVVP 2×4.0 is a shielded power cable rated 450/750 V — the largest standard RVVP 2-core size. It uses pure annealed bare copper (not tinned) for both the conductor and braid, maximizing conductivity. Two 4.0 mm² cores carry up to 28–35 A for motor feeds, main power runs on large machines, and auxiliary power to sensitive equipment. The 85% pure copper braid suppresses EMI/RFI so that power circuits run alongside electronics without noise coupling. OD ≈ 11.5 mm, ≈ 135 kg/km (est.). Max conductor temperature 70 °C, -15 to +70 °C. Intended for dry indoor environments; for damp or outdoor duty, specify tinned copper variant. Not for mains distribution or direct burial.

2. Construction Stack (Inner → Outer, expanded)

Layer / Feature Build Function
Conductor (×2) Pure annealed Cu, Class 5, 56×0.30 mm per core R ≤ 4.61 Ω/km, max conductivity
Insulation PVC ≈ 1.0 mm per core 450/750 V dielectric, colour-coded
Inner sheath PVC + filler ≈ 0.8 mm Round bedding, braid substrate
Braid shield Pure Cu, ≈ 85% coverage Low transfer impedance, EMI/RFI
Outer jacket PVC ≈ 1.2 mm Heavy-duty oil/abrasion protection

3. Electrical Characteristics

DC resistance ≤ 4.61 Ω/km at 20 °C per GB/T 3956 — roughly 38% lower than the 2.5 mm² variant, cutting voltage drop to ≈ 0.46 V per 100 m at 10 A. Rated voltage 450/750 V. Estimated ampacity ≈ 28–35 A in free air at 30 °C. Insulation resistance ≥ 25 MΩ·km. Routine AC withstand test at 2500 V for 5 minutes. Typical capacitance ≈ 190 pF/m at 1 kHz. The pure copper braid has lower resistance than tinned braid, reducing transfer impedance and improving shielding at higher frequencies. Suitable for motor feeds and 220 V AC auxiliary power runs up to 30–50 m.

Insulation & Sheath Data

Property

Value

Insulation material

PVC (Type TI2)

Outer sheath material

PVC (Type TM2)

Shield material

Tinned copper braid

Long-term service temp.

70 °C (continuous)

Max. conductor temp. (normal)

70 °C

Short-circuit temp. (≤5 s)

160 °C

Emergency overload temp.

100 °C (≤1 h)

Test voltage AC (5 min)

2.0 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹² Ω·cm

Shield

Pure copper braid, ≥ 80% coverage (EMI/RFI protection)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

300 / 300 V

GB/T 5023.5 (control/signal)

Max. system voltage

350 V AC / 500 V DC

—

Test voltage AC (5 min)

2.0 kV

Routine test

DC resistance @20 °C

≤ 4.91 Ω/km per core

GB/T 3956 Class 5 Cu max (4.0 mm²)

AC resistance @70 °C (est.)

≈ 6.14 Ω/km per core

—

Current rating in air (30 °C)

Control/medium-low-power: 25 A per core​ (recommended max.)

conservative rating

Current rating in tray (30 °C)

Control/medium-low-power: 28 A per core​

—

DC current capacity

25 A​ per core

—

Short-circuit current (1 s, Cu, 160 °C)

≈ 440 A per core

—

Capacitance (core-to-core, approx.)

≈ 0.16 µF/km

PVC

Capacitance (core-to-shield, approx.)

≈ 0.26 µF/km

PVC

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

DC / up to 100 MHz (signal)

—

Characteristic impedance (approx.)

50 – 70 Ω

signal reference

Attenuation (at 1 MHz, approx.)

≈ 0.4 dB/100 m

—


Reference values: RVVP 2×4.0 at 25 A per core, 24 V DC → max load ≈ 600 W​ per core (medium-low-power device supply). At 230 V AC → max load ≈ 5,750 VA​ per core (light power use).

4. Thermal & Flame Behaviour

Operating range -15 to +70 °C continuous. Short-circuit withstand up to 160 °C for ≤ 5 seconds. PVC insulation and jacket are flame-retardant per IEC 60332-1. The cable is halogen-containing (PVC), emitting HCl gas on burning — avoid in enclosed switchrooms. For public or enclosed spaces, specify LSZH alternatives. The heavy 1.2 mm Type ST jacket provides robust oil and abrasion resistance for presses, machine tools and welding cells. Note: bare pure copper oxidizes in humid environments — install in dry indoor or conduit-protected locations. UV resistance is limited.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

70 °C (continuous)

Max. short-circuit temp. (≤5 s)

160 °C

Emergency overload temp.

100 °C (≤1 h)

Min. installation ambient temp.

−15 °C

Service ambient range

−15 °C to +70 °C

Flexing temp. range

−5 °C to +70 °C


Fire Performance (RVVP — PVC, Non-Low-Smoke)

Property

Value / Requirement

Flame retardant

GB/T 18380.3 / IEC 60332-3​ (Category A/B/C as specified)

Halogen content

Contains halogen​ (PVC)

Smoke density

Not low-smoke​ (IEC 61034-2 not applicable)

Corrosivity

Corrosive​ (HCl emission from PVC)

Toxicity

Toxic fumes​ when burned (CO, HCl)

EMI shielding

Excellent​ (tinned copper braid, ≥85% coverage)

UV resistance

Poor​ (PVC degrades outdoors, use conduit or UV-resistant)

Water resistance

Limited​ (PVC sheath)

5. Installation Practice & Handling

Minimum bending radius ≥ 6×OD ≈ 69 mm for fixed installation; 12×OD ≈ 138 mm for drag-chain applications. The 4.0 mm² core and 11.5 mm OD make this the bulkiest RVVP 2-core variant — plan cable trays and bending allowance accordingly. Terminate the braid shield to earth via a robust shield gland or drain wire, as the cable carries higher power and fault energy. Use heavy-duty ferrules on the 56-strand conductor. Route at least 300 mm away from motor and VFD power cables. After installation, verify insulation resistance, shield continuity and polarity before energizing.


Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 6 × OD → ≈ 67 mm at Ø11.2 mm

flexible cable

Max. pulling tension

60 N per core (4.0 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Not recommended​ (PVC, non-UV, water ingress)

—

Surface mounting

Cable tray, conduit, trunking, DIN rail

—

Conduit ID

≥ 32 mm

—

Fixing

cable ties, clamps, clips

—

Impact resistance

Low (PVC)

—

Water resistance

Limited​ (PVC sheath)

—

UV resistance

Poor​ (indoor/conduit only)

—

Flex life

Excellent​ (Class 5 fine-stranded)

flexible routing

Termination note

Screw terminals, compression lugs (4 mm²), crimp terminals

—

6. Typical Service Applications

Motor feed wiring between drive output and motor terminal, main power runs on large machines and production lines, auxiliary 24 V DC and 220 V AC power to control cabinets, power to solenoid valves and actuators in heavy-duty machinery, and interconnection between main distribution and field devices. The 4.0 mm² cross-section is the sweet spot for runs up to 30–50 m where current demand is 20–35 A and EMI protection is required — for example, near servo drives, robot cells and welding equipment. Not for: mains AC distribution, high-speed fieldbus, direct burial, outdoor UV exposure, or damp environments.

RVVP 2x4.0mm² Braided Copper Shielded Servo Motor Power Cable High Load EMI Protection 300/500V

7. Testing & Quality Assurance Regime

Routine tests (100% production): DC resistance, AC voltage withstand (2500 V/5 min), insulation resistance, conductor construction, wall thickness, dimensional check, print legibility, mass per length, visual appearance, and packing. Type tests (per batch): shield coverage plus fault-current withstand, heat aging (100 °C/7 days), cold bend (-15 °C), jacket tensile, flame retardancy, and shielding effectiveness. Every drum ships with mill test certificate, ROHS and REACH declarations. The fault-current test is standard for power-grade RVVP.


Cable Parameters


RVVP 2×4.0 mm² — Full Parameter Sheet
Shielded flexible power cable · 450/750 V · pure annealed Cu Class 5 · PVC insulation/jacket · pure Cu braid ≈ 85% · GB/T 9330 / IEC 60227
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type RVVP — Flexible pure Cu, PVC ins., PVC jacket, braid shield

Rated voltage (U0/U) 450/750 V Power / motor feed / auxiliary

Number of cores 2 — 2 cores, colour-coded

Nominal cross-section 4.0 mm² Per core, Class 5 flexible

Conductor material Pure annealed copper (bare) — Class 5 per GB/T 3956, not tinned

Insulation material PVC (Type SP) — 70 °C rated, 1.0 mm wall

Shield Pure copper braid — ≈ 85% coverage, high conductivity

Outer jacket material PVC (Type ST) — Oil/abrasion resistant, 1.2 mm

Standard reference GB/T 9330 / IEC 60227 / UL 2464 — Harmonized power-control cable
02 · Conductor

Stranding 56 × 0.30 mm — Class 5 pure copper per core

Conductor diameter ≈ 2.5 mm Per core, compacted lay

DC resistance @ 20 °C ≤ 4.61 Ω/km Maximum per GB/T 3956 (pure Cu)

Conductor surface Bare pure copper — Not tinned; for dry indoor use
03 · Insulation

Insulation type PVC (Type SP) — Soft PVC, 70 °C

Insulation thickness ≈ 1.0 mm Nominal (thicker than 2.5 mm²)

Insulated core Ø ≈ 4.5 mm Per core

Insulation resistance ≥ 25 MΩ·km At 20 °C
04 · Shield & Inner Sheath

Inner sheath material PVC + polyester filler — Bedding over laid-up cores

Inner sheath thickness ≈ 0.8 mm Nominal

Shield type Pure Cu braid — Woven over inner sheath

Shield coverage ≈ 85 % Typical

Shielding effectiveness ≈ 60–70 dB At 30–1000 MHz
05 · Outer Jacket

Jacket material PVC (Type ST) — Oil/abrasion resistant

Jacket thickness ≈ 1.2 mm Nominal, heavy-duty

Overall finished diameter ≈ 11.5 mm 2-core shielded power

Approximate cable mass ≈ 135 kg/km Pure Cu + PVC + braid

Mass per 100 m ≈ 13.5 kg/100 m For drum loading
06 · Electrical

Rated voltage 450/750 V Power / motor feed

Test voltage (AC) 2500 V AC 5 min routine

DC resistance @ 20 °C ≤ 4.61 Ω/km Per GB/T 3956 (pure Cu)

Ampacity (free air) ≈ 28–35 A 4.0 mm², 70 °C

Voltage drop @ 10 A / 100 m ≈ 0.46 V I × R

Capacitance (core-core) ≈ 190 pF/m At 1 kHz
07 · Thermal & Mechanical

Max continuous conductor temp. 70 °C Normal service

Short-circuit temp. (≤5 s) 160 °C Copper limit

Min. ambient temp. -15 °C Fixed installation

Min. bending radius ≥ 6 × OD ≈ 69 mm Fixed; 12× for moving

Halogen content Halogen-containing — PVC compound
08 · Flame & Environment

Flame retardancy IEC 60332-1 — Single vertical flame

Oil resistance Good — Type ST PVC, heavy-duty

UV resistance Limited — Indoor / conduit use

Corrosion resistance Limited (bare Cu) — Dry indoor only; use tinned for damp/outdoor

ROHS / REACH Compliant — EU 2011/65/EU


Cable Test Parameters


Test Parameters — RVVP 2×4.0 mm²
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 4.61 Ω/km Routine
2 AC voltage withstand 2500 V AC, 5 min No breakdown Routine
3 Insulation resistance 500 V megohmmeter ≥ 25 MΩ·km Routine
4 Conductor construction Visual + strand count 56 × 0.30 mm pure Cu Routine
5 Wall thickness Micrometer cross-section Ins. ≈ 1.0 mm; jacket ≈ 1.2 mm Routine
6 Dimensional check Caliper OD ≈ 11.5 mm Routine
7 Print legibility Visual + rubbing Marks legible Routine
8 Mass per unit length Weighing ≈ 135 kg/km Routine
9 Appearance Visual Smooth, no blisters Routine
10 Packing Visual Drum, sealed ends, labelled Routine
11 Shield coverage + fault current Unwrap + short-circuit test ≥ 80% coverage; withstand rated fault Type
12 Heat aging test 7 days at 100 °C Retention ≥ 70% Type
13 Cold bend test -15 °C, 4 h mandrel No cracking Type
14 Jacket tensile test Universal tester Meets GB/T 9330 min. Type
15 Flame retardancy IEC 60332-1 Self-extinguish Type
16 Shielding effectiveness Triaxial / open-field ≥ 60 dB at 30–1000 MHz Type


Cable Cross Section Structure

RVVP 2x4.0mm² Braided Copper Shielded Servo Motor Power Cable High Load EMI Protection 300/500V

RVVP 2×4.0 mm² — Cross-Section Construction Diagram (Schematic)
Layered build-up: pure copper Class 5 conductors → PVC insulation → inner PVC sheath → pure copper braid shield → PVC outer jacket · 450/750 V shielded power cable · main power / motor feed · EMI/RFI protection · -15~+70 °C
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (×2) Pure annealed copper, Class 5 flexible — 56 × 0.30 mm strands per core — ≈ 2.5 (per core) Power-level current; R ≤ 4.61 Ω/km; bare pure copper for maximum conductivity
2 Insulation (per core) PVC compound (Type SP), extruded over each conductor, colour-coded ≈ 1.0 ≈ 4.5 (per insulated core) Electrical insulation; 450/750 V rated; colour-coded (red/black, blue/white, etc.)
3 Inner sheath PVC compound, extruded over the two laid-up cores, round filler ≈ 0.8 ≈ 9.6 (before braid) Round and bed the cores; mechanical protection; bedding for braid
4 Braid shield Pure copper wire braid, ≈ 85% coverage, laid over inner sheath ≈ 0.55 (effective) ≈ 10.7 EMI/RFI shielding; high conductivity for low transfer impedance
5 Outer jacket PVC compound (Type ST), black or grey, extruded over braid ≈ 1.2 ≈ 11.5 (finished) Heavy-duty outer protection; oil-, abrasion-resistant; printed markings






Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 11.5 mm 2-core shielded power cable (est.)
Approximate cable mass ≈ 135 kg/km Pure Cu + PVC + braid build-up
Nominal voltage rating 450/750 V Power / motor feed / auxiliary power
Max continuous conductor temp. 70 °C Normal service
Min. ambient / installation temp. -15 °C Fixed installation
DC resistance @ 20 °C ≤ 4.61 Ω/km Class 5 pure copper, GB/T 3956
Core count × cross-section 2 × 4.0 mm² 2 cores
Shield coverage ≈ 85 % Pure copper braid
Insulation resistance ≥ 25 MΩ·km PVC at 20 °C
Test voltage (AC) 2500 V AC / 5 min — Routine withstand test
Flame retardancy IEC 60332-1 — Single vertical flame
Shielding effectiveness ≈ 60–70 dB At 30–1000 MHz
Jacket colour Black / grey / custom — Standard: black
Mass per 100 m ≈ 13.5 kg/100 m For drum loading
Reference standard GB/T 9330 / IEC 60227 / UL 2464 — Harmonized power-control cable
Schematic — not to exact scale. Finished Ø ≈ 11.5 mm and weight ≈ 135 kg/km from cross-referenced industry samples; conductor stranding 56/0.30 mm per core and braid coverage ≈ 85%. Pure copper (not tinned) for maximum conductivity. Est. values confirmed against factory type certificate.


Construction Description


Construction Description — RVVP 2×4.0 mm²
Layer-by-layer build-up narrative · 450/750 V shielded power cable · GB/T 9330 / IEC 60227 · pure annealed copper / PVC insulation / pure copper braid shield / PVC outer jacket
1. Product Identity & Ratings
RVVP 2×4.0 is a shielded power cable rated 450/750 V — the largest standard RVVP size in the 2-core range. It uses pure annealed copper (not tinned) for both the conductor and braid, maximizing conductivity. Two 4.0 mm² cores carry up to 28–35 A for motor feeds, main power runs on machines, and auxiliary power to sensitive equipment. The braid shield suppresses EMI/RFI so that power circuits run alongside electronics without noise coupling. Max 70 °C, -15 to +70 °C range.
2. Pure Copper Conductor (×2)
Each 4.0 mm² core is stranded from 56 pure annealed copper wires of 0.30 mm in a Class 5 compacted lay-up. Pure copper (bare, not tinned) offers the highest possible conductivity: DC resistance ≤ 4.61 Ω/km at 20 °C, roughly 38% lower than 2.5 mm². The fine 56-wire stranding keeps the cable flexible despite the larger cross-section. Note: bare copper is intended for dry indoor environments where corrosion and moisture are not a concern; for outdoor or damp duty, specify tinned copper variant.
3. PVC Insulation
Each conductor receives a 1.0 mm Type SP PVC extrusion — thicker than the 0.8 mm wall on 2.5 mm² cores to match the 450/750 V power rating and higher current. The insulation is colour-coded for polarity and circuit identification. Insulation resistance ≥ 25 MΩ·km. The thicker wall improves dielectric margin and provides additional mechanical protection for the larger conductor.
4. Inner Sheath + Braid Shield
The two insulated cores are laid up with polyester fillers to keep the cable round, then bedded with a 0.8 mm PVC inner sheath. Over this, a pure copper braid is woven at ≈ 85% coverage. Pure copper braid has lower resistance than tinned braid, reducing transfer impedance and improving shielding performance at higher frequencies. Because the 4.0 mm² core carries more current, the braid is also sized for higher earth-fault energy.
5. Outer PVC Jacket
A 1.2 mm Type ST PVC jacket completes the build, yielding an OD of ≈ 11.5 mm — the bulkiest RVVP 2-core variant. The heavy jacket provides oil and abrasion resistance for presses, machine tools and welding cells, and is flame-retardant per IEC 60332-1. Printed markings show product type, cross-section, voltage, metre mark and manufacturer. For drag-chain duty, specify RVVSP variant.

8. Factory Advantages

Pure annealed copper conductor at 56×0.30 mm stranding delivers maximum conductivity (4.61 Ω/km) with Class 5 flexibility. Thicker 1.0 mm insulation and 1.2 mm heavy-duty jacket match the 450/750 V power rating. Pure copper braid at ≈ 85% coverage offers lower transfer impedance than tinned braid. Low DC resistance minimizes voltage drop on longer power runs. Heavy-duty oil-resistant Type ST jacket for press and machine tool duty. 100% routine electrical QA on every drum. Cut-to-length on wooden drums. Full traceability with MTC and certification support for industrial machinery tenders.


9. Packaging, Storage & Logistics

Cut to customer-specified length on export-grade wooden drums, with both ends heat-sealed. At ≈ 135 kg/km, drums are essential for lengths over 100 m to avoid coil distortion and cable damage. Drums wrapped in waterproof film and corrugated cardboard, labelled with product type, core count, cross-section, length, weight, production date and drum number. Standard lengths 100/200/500/1000 m. Store dry indoor, -10 to +40 °C, below 75% RH, away from direct sunlight and chemical solvents. FOB Shanghai/Nanjing/Qingdao; CIF and DAP available. Sample lead time 5–7 days; bulk production 15–25 days.


RVVP 2x4.0mm² Braided Copper Shielded Servo Motor Power Cable High Load EMI Protection 300/500V

10. Procurement Specification

State cable designation "RVVP 2×4.0 pure copper", required length per drum, and core colour preference. Request the routine AC withstand test record (2500 V), shield coverage certificate, and fault-current test result. Note that this is a pure copper (bare) variant for dry indoor use — for damp or outdoor applications, specify the tinned copper variant. Specify any regional certification requirements (UL 2464, CE, etc.) at order time. Payment: 30% T/T deposit, balance against B/L copy. Documents: MTC, ROHS/REACH, COO, commercial invoice, packing list. For drag-chain duty, specify RVVSP variant.

11. Cable Industry FAQ

Q1: Why pure copper instead of tinned? Bare pure copper has slightly higher conductivity than tinned copper (lower resistance), making it ideal for indoor power circuits where corrosion is not a concern.

Q2: Where should I NOT use bare copper? Damp or humid environments, outdoor exposure, or anywhere moisture may cause oxidation — specify tinned copper variant instead.

Q3: What is the current rating? ≈ 28–35 A in free air at 30 °C; derate in bundles or conduits.

Q4: Can it power motors? Yes — it is designed for motor feeds and heavy-duty auxiliary power up to 35 A at 450/750 V.

Q5: What is the voltage drop at 10 A? ≈ 0.46 V per 100 m — roughly half the drop of 2.5 mm², ideal for longer power runs.

Q6: How does the pure copper braid compare? Pure copper braid has lower resistance than tinned braid, reducing transfer impedance and improving shielding performance at higher frequencies.

Q7: Is it suitable for drag chains? Not as standard — specify RVVSP (flexible braid) variant for continuous-flex applications.

Q8: What is the bending radius? ≥ 6×OD ≈ 69 mm for fixed; 12× for moving applications.

Q9: What is the temperature range? -15 to +70 °C continuous.

Q10: What proof ships? Routine AC test record (2500 V) + shield coverage + fault-current test + MTC.

Q11: Why is the OD so large? The 11.5 mm diameter reflects the 4.0 mm² conductor, thicker insulation (1.0 mm), and heavy-duty 1.2 mm jacket required for power-grade service.