低電圧電源ケーブル
ZR-YJV 単芯ケーブル 1 X 300mm2 耐火 0.6/1kV ソリッド銅 XLPE絶縁
ZR-YJV 1*300mm² Flame Retardant Single Core Cable, 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Construction Power Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed ZR-YJV 1×300 mm² — Cable Profile 1. Identity. The ZR-YJV 1×300 is the 300 mm² class of the flame-retardant ...
建設現場電源ケーブル ZR-YJV 4x35mm2+1x16mm2 耐火銅 XLPE
Construction Site Power Cable ZR-YJV 4x35mm²+1x16mm² Flame Retardant Copper XLPE Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
ZR-YJV 4x95mm2 耐火銅コア電源ケーブル 工業建築用
ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, ...
1*150mm2 単芯銅線 XLPE絶縁 PVCシース 建築配線用
ZR-YJV 1*150mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Construction Wiring Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed. 1. Identity & Standards. The ZR-YJV 1×150 is a single-conductor, flame-retarded power cable with a CU/XLPE/PVC make-up, rated ...
0.6/1kV XLPE銅ケーブル ZR-YJV 4x25mm²+1x16mm² 電力供給用難燃
0.6/1kV XLPE Copper Cable ZR-YJV 4x25mm²+1x16mm² Flame Retardant for Power Supply Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
ZR-YJV 4×70mm² 0.6/1kV 耐火難燃銅ケーブル、XLPE絶縁、ビル電力配電用
ZR-YJV 4×70mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame...
2 X 70mm2 2 コアケーブル ZR-YJV 耐火性PVC保温ジャケット 0.6/1kV
ZR-YJV 2*70mm² Flame Retardant 2 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Jacket ZR-YJV 2×70 mm² — Specification Review 1. Product Summary. ZR-YJV 2×70 is a two-core flame-retardant power cable — twin 70 mm² copper ...
1x120mm2 単芯ケーブル フルゲージ 純銅製 アンチエイジング 耐火性 電源
ZR-YJV 1*120mm² Flame Retardant Power Cable, 0.6/1kV Full Gauge Pure Copper, XLPE Insulation Anti-Aging PVC Sheath for Engineering Projects Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed ZR-YJV 1×120 mm² — Technical Dossier 1. Scope & Certification. This dossier covers the ZR...
4+1コア 4*16mm2 + 1*10mm2 銅電源ケーブル ZR-YJV XLPE 阻燃性0.6/1kV
4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...