"pvc or lszh low smoke zero halogen electrical building wires"
Please try a different search term or browse our product categories.
1500V 太陽光電池ケーブル ハロゲンフリー 5級 柔軟な太陽光電池線
H1Z2Z2-K 6.0mm² TUV 1500V DC Solar Main Cable UV Resistant PV Photovoltaic Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) ...
IEC 62930 ソーラーワイヤー 錫メッキ銅 0.095kg/M 太陽光パネル用PVワイヤー
PV Cable PV1-F 6.0mm² TUV 1500V DC Low Smoke Halogen Free Solar Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, ...
ソーラー メインケーブル PV1-F 6.0mm2 TUV 1500V DC 重用 PV 光伏線
Solar Main Cable PV1-F 6.0mm² TUV 1500V DC Heavy Duty PV Photovoltaic Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
YJV22 中圧電源ケーブル 3x150mm2 銅 Mv 装甲ケーブル 15kV
YJV22 3x150mm² Copper XLPE Armored MV Cable 8.7/15kV Reliable Underground Power Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 22 Steel tape armoured (double steel tape) 3×150 mm² Three cores, each 150 mm² copper Construction: Copper ...
3x400mm2 中圧電力ケーブル アルミニウム XLPE 鎧付き MVケーブル 8.7kV
YJLV22 3x400mm² Aluminum XLPE Armored MV Cable 8.7/15kV Cost Effective Underground Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC outer sheath 22 Steel tape armoured (double steel tape) 3×400 mm² Three cores, each ...
XLPE アルミ電源ケーブル YJLV22 3x50mm2 8.7/15kV 装甲式3コアMV
XLPE Aluminum Power Cable YJLV22 3x50mm² 8.7/15kV Armored 3 Core MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
3コア armored MVケーブル YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPEパワーケーブル
3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
BTTRZ X50mm2+1x25mm2 耐火ケーブル ミネラル 緊急電源 銅被覆ケーブル
BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire/power cable) T Copper conductor (Tong = copper) T Copper sheath (Tong = copper) R Flexible (Rou = flexible) Z Heavy ...