"and other insulations flexible copper wire conductor bare or tinned"
Please try a different search term or browse our product categories.
RVV 5x4.0mm2 5芯フレキシブルケーブル PVCマルチサーキット撚り線フレキシブル銅ケーブル
RVV 5x4.0mm2 5 Core Flexible PVC Stranded Copper Cable 300/500V Multi Circuit Cable Designation & Meaning Code Meaning R Flexible conductor (Class 5 fine-stranded copper) V PVC (polyvinyl chloride) insulation V PVC (polyvinyl chloride) outer sheath 5×4.0 mm² Five cores, each 4.0 mm² flexible copper ...
白銅ビルワイヤー PVC絶縁単心家庭用電線
BV 2.5mm2 White PVC Insulated Single Core Copper Building Wire 450/750V Household Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain ...
1.0mm2 軟銅導体 焼きなまし 18 AWG 無被覆銅線
BV 1.0 mm² / 18 AWG — Technical Specification Category Parameter Value / Description Product Identity Model Number BV (equivalent to 60227 IEC 01 / IEC 05) Product Name Copper Conductor PVC Insulated Single-Core Building Wire Standards Compliance GB/T 5023.3-2008, JB/T 8734.2-2016 Certification CCC ...
1500V 太陽光電池ケーブル ハロゲンフリー 5級 柔軟な太陽光電池線
H1Z2Z2-K 6.0mm² TUV 1500V DC Solar Main Cable UV Resistant PV Photovoltaic Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) ...
銅製の太陽光電池ケーブル ソーラーパネル 紫外線耐性PVワイヤー
Solar Panel Cable H1Z2Z2-K 4.0mm² TUV 1500V DC UV Resistant PV Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen...
高容量MVケーブル YJV22 3x95mm² 8.7/15kV アーマードXLPEパワーケーブル
High Capacity MV Cable YJV22 3x95mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
BTLY 耐火ケーブル 4x35mm2 + 1x16mm2 アルミニウム被覆ケーブル 緊急用
NG-A BTLY 4x35+1x16mm2 Mineral Insulated Fire Resistant Aluminum Sheath Cable for Emergency Cable Designation & Meaning Code Meaning NG-A New Generation A-class fire-resistant (Chinese designation) (BTLY) Building wire, Thin copper conductor, Lightweight Y— alternative naming convention indicating: ...
BTTRZ X50mm2+1x25mm2 耐火ケーブル ミネラル 緊急電源 銅被覆ケーブル
BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire/power cable) T Copper conductor (Tong = copper) T Copper sheath (Tong = copper) R Flexible (Rou = flexible) Z Heavy ...