سلك نحاسي صلب أزرق BV 2.5 مم2 سلك نحاسي صلب للاستخدام الكهربائي المنزلي
Blue BV 2.5mm² PVC Copper Conductor Neutral Wire Household Electrical Wiring Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or ...
1.0mm2 موصل النحاس الصلبة 18 Awg سلك النحاس العاري
BV 1.0 mm² / 18 AWG — Technical Specification Category Parameter Value / Description Product Identity Model Number BV (equivalent to 60227 IEC 01 / IEC 05) Product Name Copper Conductor PVC Insulated Single-Core Building Wire Standards Compliance GB/T 5023.3-2008, JB/T 8734.2-2016 Certification CCC ...
?
Photovoltaic Cable 4.0mm2 PV1-F TUV DC Solar Panel Connection Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
3x400mm2 كابل الجهد المتوسط XLPE سلك XLPE مدرع 26KV 35kV
YJLV22 3x400mm² Aluminum XLPE Armored HV Cable 26/35kV for Urban Power Distribution Cable Designation & Meaning Code Meaning 26/35 kV Rated voltage: U₀ = 26 kV (phase-to-earth), U = 35 kV (phase-to-phase) YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC ...
كابل طاقة متوسط الجهد 3x300 مم2 XLPE سوبر هيفي ألومنيوم
Super Heavy Aluminum Cable YJLV22 3x300mm² 8.7/10kV 8.7/15kV Armored XLPE MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7...
كابل طاقة مدرع XLPE عالي السعة MV YJV22 3x95 مم² 8.7/15kV
High Capacity MV Cable YJV22 3x95mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
كابل BTTRZ مقاوم للحريق 4x150 مم2 + 1x120 مم2 كابل معزول معدني
Ultra Fire Cable BTTRZ 4x150mm²+1x120mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
سلك كبير محصن للحريق 4x95mm2 + 1x70mm2 كابل تسخين عازل معدني
Large Fire Cable BTTRZ 4x95mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...