logo
Anhui Tongdu International Trade Co., Ltd.
Online -Service

Online -Service

Gesprächspartner
+86 19056002718
WeChat QR-Code
Folgen Sie uns.
Search Results For:

"power 4 core flexible cable"

- 90 Items Found
Qualität Klasse 2 25mm2 2-adriges Kabel flammwidriges Kupferkabel XLPE-Isolierung PVC-Mantel usine

Klasse 2 25mm2 2-adriges Kabel flammwidriges Kupferkabel XLPE-Isolierung PVC-Mantel

ZR-YJV 2*25mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Power Distribution Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed. ZR-YJV 2×25 mm² — Product Data Review 1. Product Summary. ZR-YJV 2×25 is a two-core flame-retardant power cable — twin 25 mm² ...

Qualität 2x35mm2 2 Kerne Kabel Stranded Kupfer Niederspannung Stromkabel ZR Grade usine

2x35mm2 2 Kerne Kabel Stranded Kupfer Niederspannung Stromkabel ZR Grade

ZR-YJV 2*35mm² Flame Retardant 2 Core Cable, 0.6/1kV Stranded Copper, XLPE Insulation PVC Jacket for Construction Power Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Jacket ZR-YJV 2×35 mm² — Technical Data Review 1. Product Summary. ZR-YJV 2×35 is a two-core flame-retardant power cable — ...

Qualität 2 X 70mm2 2 Kerne Kabel ZR-YJV Flammschutz PVC Isolationsjacke 0,6/1kV usine

2 X 70mm2 2 Kerne Kabel ZR-YJV Flammschutz PVC Isolationsjacke 0,6/1kV

ZR-YJV 2*70mm² Flame Retardant 2 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Jacket ZR-YJV 2×70 mm² — Specification Review 1. Product Summary. ZR-YJV 2×70 is a two-core flame-retardant power cable — twin 70 mm² copper ...

Qualität Z usine

Z

ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath Code Mean:ZR-Flame Retardant,YJ-XLPE Insulated,V-PVC Sheath ZR-YJV 4×35 mm² — Cable Data Report 1. Product at a Glance. ZR-YJV 4×35 is a four-core flame-retardant LV cable — four 35 mm² copper conductors, XLPE ...

Qualität ZR-YJV 4x95mm² Flammhemmendes Kupferkern-Stromkabel für den Industrie- und Hochbau usine

ZR-YJV 4x95mm² Flammhemmendes Kupferkern-Stromkabel für den Industrie- und Hochbau

ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, ...

Qualität Feuerbeständiges Kabel BTTRZ 4x50mm²+1x25mm² Mineralisoliert 0,6/1kV usine

Feuerbeständiges Kabel BTTRZ 4x50mm²+1x25mm² Mineralisoliert 0,6/1kV

Fire Resistant Cable BTTRZ 4x50mm²+1x25mm² Mineral Insulated 0.6/1kV Technical Datasheet — BTTRZ 0.6/1 kV 4×50 mm² + 1×25 mm² Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = ...

Qualität 4+1 Kern BTTRZ 4x16mm2+1x10mm2 Mineralisoliertes feuerfestes Kabel 0,6/1kV usine

4+1 Kern BTTRZ 4x16mm2+1x10mm2 Mineralisoliertes feuerfestes Kabel 0,6/1kV

4+1 Core BTTRZ 4x16mm²+1x10mm² Mineral Insulated Fire Resistant Cable 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...

Qualität Rauchmelder flammhemmendes Kabel rund 1300kg/km mineralisoliertes Kupferkabel usine

Rauchmelder flammhemmendes Kabel rund 1300kg/km mineralisoliertes Kupferkabel

Smoke Detector Cable 4+1 Core 10mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...

Qualität 25 mm2 feuerfestes Kabel 4x25 mm2 + 1x16 mm2 Mineral-isoliertes Kupfer usine

25 mm2 feuerfestes Kabel 4x25 mm2 + 1x16 mm2 Mineral-isoliertes Kupfer

0.6/1kV Mineral Insulated Cable BTTRZ 4x25mm²+1x16mm² Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...