logo
Anhui Tongdu International Trade Co., Ltd.
Layanan online

Layanan online

Kontak person
+86 19056002718
Kode QR WeChat
Ikuti kami.
Search Results For:

"power 4 core flexible cable"

- 90 Items Found
kualitas Kabel Tembaga Tahan Api Inti 2 25mm2 Kelas 2 Isolasi Xlpe Selubung Pvc pabrik

Kabel Tembaga Tahan Api Inti 2 25mm2 Kelas 2 Isolasi Xlpe Selubung Pvc

ZR-YJV 2*25mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Power Distribution Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed. ZR-YJV 2×25 mm² — Product Data Review 1. Product Summary. ZR-YJV 2×25 is a two-core flame-retardant power cable — twin 25 mm² ...

kualitas Kabel 2x35mm2 2 Inti Tembaga Serat Tegangan Rendah Grade ZR pabrik

Kabel 2x35mm2 2 Inti Tembaga Serat Tegangan Rendah Grade ZR

ZR-YJV 2*35mm² Flame Retardant 2 Core Cable, 0.6/1kV Stranded Copper, XLPE Insulation PVC Jacket for Construction Power Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Jacket ZR-YJV 2×35 mm² — Technical Data Review 1. Product Summary. ZR-YJV 2×35 is a two-core flame-retardant power cable — ...

kualitas Kabel 2 X 70mm2 2 Inti ZR-YJV Tahan Api Isolasi PVC Selubung 0.6/1kV pabrik

Kabel 2 X 70mm2 2 Inti ZR-YJV Tahan Api Isolasi PVC Selubung 0.6/1kV

ZR-YJV 2*70mm² Flame Retardant 2 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Jacket ZR-YJV 2×70 mm² — Specification Review 1. Product Summary. ZR-YJV 2×70 is a two-core flame-retardant power cable — twin 70 mm² copper ...

kualitas Kabel Daya Tembaga Tahan Api ZR-YJV 4×35mm², Isolasi XLPE 0.6/1kV Selubung PVC pabrik

Kabel Daya Tembaga Tahan Api ZR-YJV 4×35mm², Isolasi XLPE 0.6/1kV Selubung PVC

ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath Code Mean:ZR-Flame Retardant,YJ-XLPE Insulated,V-PVC Sheath ZR-YJV 4×35 mm² — Cable Data Report 1. Product at a Glance. ZR-YJV 4×35 is a four-core flame-retardant LV cable — four 35 mm² copper conductors, XLPE ...

kualitas Kabel Daya Tembaga Inti Tahan Api ZR-YJV 4x95mm² untuk Konstruksi Industri pabrik

Kabel Daya Tembaga Inti Tahan Api ZR-YJV 4x95mm² untuk Konstruksi Industri

ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, ...

kualitas Kabel tahan api BTTRZ 4x50mm2 + 1x25mm2 Mineral Terisolasi 0.6/1kV pabrik

Kabel tahan api BTTRZ 4x50mm2 + 1x25mm2 Mineral Terisolasi 0.6/1kV

Fire Resistant Cable BTTRZ 4x50mm²+1x25mm² Mineral Insulated 0.6/1kV Technical Datasheet — BTTRZ 0.6/1 kV 4×50 mm² + 1×25 mm² Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = ...

kualitas Kabel Tahan Api BTTRZ 4+1 Core 4x16mm²+1x10mm² Berinsulasi Mineral 0.6/1kV pabrik

Kabel Tahan Api BTTRZ 4+1 Core 4x16mm²+1x10mm² Berinsulasi Mineral 0.6/1kV

4+1 Core BTTRZ 4x16mm²+1x10mm² Mineral Insulated Fire Resistant Cable 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...

kualitas Kabel Tahan Api Detektor Asap Bulat 1300kg/Km Kabel Tembaga Berinsulasi Mineral pabrik

Kabel Tahan Api Detektor Asap Bulat 1300kg/Km Kabel Tembaga Berinsulasi Mineral

Smoke Detector Cable 4+1 Core 10mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...

kualitas 25 mm2 Kabel tahan api 4x25mm2 + 1x16mm2 Tembaga terisolasi mineral pabrik

25 mm2 Kabel tahan api 4x25mm2 + 1x16mm2 Tembaga terisolasi mineral

0.6/1kV Mineral Insulated Cable BTTRZ 4x25mm²+1x16mm² Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...