High Rise Building Main Cable ZR-YJV 4x95mm²+1x50mm² XLPE Copper Flame Retardant
High Rise Building Main Cable ZR-YJV 4x95mm²+1x50mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×95 mm² + 1×50 mm² Four cores of 95 mm² (3 phase + 1 neutral) + one ...
Heavy Duty 4+1 Core Cable ZR-YJV 4x120mm²+1x70mm² XLPE Copper Flame Retardant
Heavy Duty 4+1 Core Cable ZR-YJV 4x120mm²+1x70mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×120 mm² + 1×70 mm² Four cores of 120 mm² (3 phase + 1 neutral) + one ...
Shopping Mall Main Power Cable ZR-YJV 4x150mm²+1x70mm² XLPE Copper Flame Retardant
Shopping Mall Main Power Cable ZR-YJV 4x150mm²+1x70mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×150 mm² + 1×70 mm² Four cores of 150 mm² (3 phase + 1 neutral) + ...
Flame Retardant XLPE Cable 4+1 Core 4×185mm²+1*95mm² ZR-YJV Copper 0.6/1kV
Flame Retardant XLPE Cable 4+1 Core 4×185mm²+1*95mm² ZR-YJV Copper 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×185 mm² + 1×95 mm² Four cores of 185 mm² (3 phase + 1 neutral) + one earth ...
Access Control 5 Core Flexible Cable RVV 5x1.0mm2 PVC Stranded Copper Flexible
Access Control Cable RVV 5x1.0mm² PVC Stranded Copper Flexible Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 5×1.0 mm² Five flexible cores, each 1.0 mm² copper conductor ...
Industrial Equipment 5 Core Flexible Cable RVV 5x2.5mm2 PVC Stranded Copper
Industrial Equipment Cable RVV 5x2.5mm² PVC Stranded Copper Flexible Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 5×2.5 mm² Five flexible cores, each 2.5 mm² copper ...
Stranded Copper Wire 5 Core Cable RVV 5x6.0mm² PVC Flexible 300/500V
Stranded Copper Wire 5 Core Cable RVV 5x6.0mm² PVC Flexible 300/500V Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 5×6.0 mm² Five flexible cores, each 6.0 mm² copper ...
ZR-YJV 4*10mm² Flame Retardant 4 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power
ZR-YJV 4*10mm² Flame Retardant 4 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×10 mm² Four equal cores of 10 mm² copper ...
ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath
ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×35 mm² Four equal cores of 35 mm² copper conductor Construction ...