"power 4 core flexible cable"
- 90 Items Found
كابل مضاد للحرائق للمستشفى معدني 3200kg / km Mi كابل التدفئة
Hospital Critical Cable BTTRZ 4x35mm²+1x16mm² Mineral Insulated Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...
كابل مقاوم للحريق 4x70 مم2 + 1x50 مم2 1 كيلو فولت 1.2 كيلو فولت كابل معدني معزول نحاسي عاري
Heavy Duty Fire Cable BTTRZ 4x70mm²+1x50mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...
سلك كبير محصن للحريق 4x95mm2 + 1x70mm2 كابل تسخين عازل معدني
Large Fire Cable BTTRZ 4x95mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...
4+1 كابل مقاوم للنار من النواة 120mm2+1x95mm2 BTTRZ كابل المحطة الفرعية للنار
Fire Substation Cable 4+1 Core 120mm²+1x95mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6...
كابل BTTRZ مقاوم للحريق 4x150 مم2 + 1x120 مم2 كابل معزول معدني
Ultra Fire Cable BTTRZ 4x150mm²+1x120mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
4x185mm2 + 1x150mm2 كابل مقاوم للحريق 0.6KV 1KV كابل النحاس المعزول من المعادن
Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
كابل متوسط الجهد مرن 3x240 مم2 8.7 كيلو فولت 15 كيلو فولت كابل 3 قلب
XLPE Medium Voltage Aluminum Cable YJLV22 3x240mm2 8.7/15kV Armored 3 Core Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 ...
ZC-YJV 4x50mm2 فئة C مضاد للحريق XLPE كابل الطاقة النحاسي لتوزيع المباني
ZC-YJV 4x50mm² Class C Flame Retardant XLPE Copper Power Cable for Building Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Category C (GB/T 18380.3) YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 4×50 mm² Four cores, each 50 mm² copper (3 phases + 1 ...
موصل الألومنيوم XLPE كابل 3 النواة 25mm2 YJLV22 8.7/10kV مدرعة
Aluminum Conductor XLPE Cable 3 Core 25mm² YJLV22 8.7/10kV Armored Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...