Search Results For:

"power 4 core flexible cable"

- 90 Items Found
품질 병원용 내화 미네랄 케이블 3200kg/km MI 히팅 케이블 공장

병원용 내화 미네랄 케이블 3200kg/km MI 히팅 케이블

Hospital Critical Cable BTTRZ 4x35mm²+1x16mm² Mineral Insulated Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...

품질 4x70mm2 + 1x50mm2 방화 케이블 1KV 1.2KV 광물 단열 케이블 공장

4x70mm2 + 1x50mm2 방화 케이블 1KV 1.2KV 광물 단열 케이블

Heavy Duty Fire Cable BTTRZ 4x70mm²+1x50mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...

품질 대형 내화 전선 4x95mm2+1x70mm2 미네랄 절연 난방 케이블 공장

대형 내화 전선 4x95mm2+1x70mm2 미네랄 절연 난방 케이블

Large Fire Cable BTTRZ 4x95mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...

품질 4+1 코어 내화 케이블 120mm2+1x95mm2 BTTRZ 내화 변전소 케이블 공장

4+1 코어 내화 케이블 120mm2+1x95mm2 BTTRZ 내화 변전소 케이블

Fire Substation Cable 4+1 Core 120mm²+1x95mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6...

품질 BTTRZ 불 retardant 케이블 4x150mm2 + 1x120mm2 미네랄 격리 케이블 공장

BTTRZ 불 retardant 케이블 4x150mm2 + 1x120mm2 미네랄 격리 케이블

Ultra Fire Cable BTTRZ 4x150mm²+1x120mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...

품질 4x185mm2 + 1x150mm2 방화 케이블 0.6KV 1KV 광물 단열 구리 케이블 공장

4x185mm2 + 1x150mm2 방화 케이블 0.6KV 1KV 광물 단열 구리 케이블

Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...

품질 3x240mm2 유연 중전압 케이블 8.7kV 15kV 3심 케이블 공장

3x240mm2 유연 중전압 케이블 8.7kV 15kV 3심 케이블

XLPE Medium Voltage Aluminum Cable YJLV22 3x240mm2 8.7/15kV Armored 3 Core Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 ...

품질 ZC-YJV 4x50mm² 내화성 XLPE 구리 전력 케이블 (건물 분배용) 공장

ZC-YJV 4x50mm² 내화성 XLPE 구리 전력 케이블 (건물 분배용)

ZC-YJV 4x50mm² Class C Flame Retardant XLPE Copper Power Cable for Building Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Category C​ (GB/T 18380.3) YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 4×50 mm² Four cores, each 50 mm² copper (3 phases + 1 ...

품질 알루미늄 선도자 XLPE 케이블 3 코어 25mm2 YJLV22 8.7/10kV 장갑 공장

알루미늄 선도자 XLPE 케이블 3 코어 25mm2 YJLV22 8.7/10kV 장갑

Aluminum Conductor XLPE Cable 3 Core 25mm² YJLV22 8.7/10kV Armored Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor ​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...