"2 x 70mm2 2 core cable"
Please try a different search term or browse our product categories.
4.0mm2 Katı Bakır iletken 450V 750V Tek iplik bakır tel
BV 4.0mm² Solid Copper PVC Insulated Building Wire 450/750V Easy Pull Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 4.0 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor ...
1.0mm2 Katı Bakır İletken 18 Awg Çıplak Bakır Tel
BV 1.0 mm² / 18 AWG — Technical Specification Category Parameter Value / Description Product Identity Model Number BV (equivalent to 60227 IEC 01 / IEC 05) Product Name Copper Conductor PVC Insulated Single-Core Building Wire Standards Compliance GB/T 5023.3-2008, JB/T 8734.2-2016 Certification CCC ...
IEC 62930 Güneş Kablosu Kalaylı Bakır 0.095kg/M Güneş Panelleri İçin Pv Kablo
PV Cable PV1-F 6.0mm² TUV 1500V DC Low Smoke Halogen Free Solar Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, ...
Güneş Paneli Bağlantı Kablosu PV1-F 4.0mm² TUV 1500V DC Hava Koşullarına Dayanıklı PV Kablosu
Solar Panel Connection Cable PV1-F 4.0mm² TUV 1500V DC Weatherproof PV Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor...
Fotovoltaik Kablo 4.0mm² PV1-F TUV DC Güneş Paneli Bağlantı Kablosu
Photovoltaic Cable 4.0mm2 PV1-F TUV DC Solar Panel Connection Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
YJV22 Orta Gerilim Güç Kablosu 3x150mm2 Bakır MV Zırhlı Kablo 15kV
YJV22 3x150mm² Copper XLPE Armored MV Cable 8.7/15kV Reliable Underground Power Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 22 Steel tape armoured (double steel tape) 3×150 mm² Three cores, each 150 mm² copper Construction: Copper ...
BTTRZ X50mm2+1x25mm2 Yangına Dayanıklı Kablo Mineral Acil Durum Güç Bakır Kılıflı Kablo
BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire/power cable) T Copper conductor (Tong = copper) T Copper sheath (Tong = copper) R Flexible (Rou = flexible) Z Heavy ...
4x70mm2+1x50mm2 Yangına Dayanıklı Kablo 1KV 1.2KV Bakır İletkenli Mineral Yalıtımlı Kablo
Heavy Duty Fire Cable BTTRZ 4x70mm²+1x50mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...