"2 x 70mm2 2 core cable"
Please try a different search term or browse our product categories.
黄色のPVC銅単心スイッチワイヤー 450v 750V 照明制御ケーブル
Yellow BV 2.5mm² PVC Copper Single Core Switch Wire 450/750V Lighting Control Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor ...
6.0mm2 光伏太陽光ケーブル 耐天候XLPOUV耐太陽光ケーブル
UV Resistant Solar Cable H1Z2Z2-K 6.0mm² TUV 1500V DC Weatherproof PV Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z ...
1500V 太陽光電池ケーブル ハロゲンフリー 5級 柔軟な太陽光電池線
H1Z2Z2-K 6.0mm² TUV 1500V DC Solar Main Cable UV Resistant PV Photovoltaic Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) ...
IEC 62930 ソーラーワイヤー 錫メッキ銅 0.095kg/M 太陽光パネル用PVワイヤー
PV Cable PV1-F 6.0mm² TUV 1500V DC Low Smoke Halogen Free Solar Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, ...
ソーラーパネル接続ケーブル PV1-F 4.0mm2 TUV 1500V DC 防天光電線
Solar Panel Connection Cable PV1-F 4.0mm² TUV 1500V DC Weatherproof PV Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor...
8.7KV 10kV Mv 電源ケーブル 装甲式摩天楼 メインアルミケーブル
Skyscraper Main Aluminum Cable YJLV22 3x400mm2 8.7/10kV 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 ...
4x185mm2+1x150mm2 耐火ケーブル 0.6KV 1KV ミネラル絶縁銅ケーブル
Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
BTTRZ 耐火ケーブル 4x150mm2+1x120mm2 鉱物隔離ケーブル
Ultra Fire Cable BTTRZ 4x150mm²+1x120mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...