2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant
Product Summary
Product Details
2.5mm2 solid copper conductor
,ground earth solid thhn
,solid copper conductor ground earth
Product Description
Yellow Green BV 2.5mm² Ground Earth Wire PVC Insulated Copper Cable
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
B |
Fixed wiring cable (Class B — building wire) |
|
V |
PVC (polyvinyl chloride) insulation |
|
2.5 mm² |
Nominal cross-sectional area of conductor |
Construction: Plain copper conductor (solid or stranded), PVC insulation, single-core non-sheathed building wire.
Applicable Standards
- GB/T 5023-2008 / IEC 60227 — Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V
- GB/T 3956 / IEC 60228 — Conductors (Class 1 solid or Class 2 stranded, copper)
- GB/T 18380 / IEC 60332 — Flame retardant tests
- GB/T 2951 / IEC 60811 — Insulating and sheathing materials — Common test methods

BV-2.5 mm² (green-yellow striped, PE protective earth — IEC 60446 / GB 7947) — Copper PVC-Insulated Building Wire Specification & Engineering Data
1. Product Overview & Rating Summary. BV-2.5 (green-yellow striped) is the standard Chinese copper PVC-insulated building wire rated 450/750 V AC for interior fixed wiring, built and tested per GB/T 5023 / JB/T 8734. This is the IEC 60446 / GB 7947 standard PE (protective earth) conductor colour — green-yellow diagonal stripes. Unlike solid green (used for specific bonding applications), green-yellow striped is reserved EXCLUSIVELY for protective earthing and must never be used for phase, neutral, or control circuits. Finished diameter is about 3.6 mm, mass about 22 kg/km, supplied in 100 m coils.
2. Layer-by-Layer Construction (Conductor to Outer).
| Layer | Construction | Wall | Diameter |
|---|---|---|---|
| Conductor | Solid round annealed copper wire, Class 1 | — | 1.78 mm |
| Insulation | Polyvinyl chloride (PVC), green-yellow striped | 0.8 mm | ≈ 3.6 mm (finished) |
| Outer sheath | None — insulation is the outer layer | — | — |
3. Electrical Characteristics. The 2.5 mm² conductor is a solid 1.78 mm annealed copper wire (Class 1, not stranded), giving a maximum DC resistance of 7.41 Ω/km at 20 °C. Routine proof is 2.0 kV AC / 5 minutes. Insulation resistance ≥ 0.011 MΩ·km. With the single core in free air at 30 °C, reference loading is about 24 A; in conduit with three grouped cores, the rating derates to about 19 A. For PE circuits, low loop resistance is critical to ensure protective devices operate during earth faults. Conductor loss at 24 A is about 4.3 W per metre at 70 °C.
Insulation Data
|
Property |
Value |
|---|---|
|
Material |
PVC (polyvinyl chloride) |
|
Nominal thickness |
0.8 mm |
|
Long-term service temp. |
70 °C (continuous) |
|
Short-circuit temp. (≤5 s) |
160 °C (Cu conductor limit per IEC 60228) |
|
Emergency overload temp. |
90 °C (short term) |
|
Weather resistance |
Limited — for indoor/dry use only; not UV-resistant |
|
Flame retardant |
GB/T 18380.3 Category C (ZC) available; standard version passes IEC 60332-1 |
|
Smoke density |
Standard (non-low-smoke) |
|
Halogen content |
Contains halogen (PVC) |
|
Corrosivity |
Corrosive (PVC) |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
450 / 750 V |
GB/T 5023 / IEC 60227 |
|
Test voltage AC (50 Hz, 5 min) |
2500 V |
Routine test |
|
DC resistance @20 °C |
≤ 7.41 Ω/km |
GB/T 3956 Class 1 max, 2.5 mm² (solid Cu) |
|
AC resistance @70 °C (est.) |
≈ 9.40 Ω/km |
per core |
|
Capacitance (approx.) |
negligible |
single-core building wire |
|
Inductive reactance (approx.) |
negligible |
— |
|
Current rating in conduit (30 °C ambient) |
24 A |
single-phase, 2-core circuit (GB/T 16895) |
|
Current rating in free air (30 °C) |
27 A |
single cable |
|
Current rating buried (20 °C) |
22 A |
direct in soil (not recommended) |
|
Short-circuit current (1 s, Cu, 160 °C) |
≈ 0.25 kA (250 A) |
2.5 mm² Cu |
|
Frequency |
50/60 Hz AC |
— |
Reference values: 2.5 mm² Cu at 24 A, single-phase 230 V → max load ≈ 5.5 kW. Voltage drop at 24 A ≈ 17.8 V/km per core (≈0.78% per 10 m at 230 V).
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
70 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
160 °C (Cu conductor) |
|
Emergency overload temp. |
90 °C (short term) |
|
Min. installation ambient temp. |
0 °C (PVC insulation); below 0 °C pre-heating required |
|
Service ambient range |
−15 °C to +70 °C (indoor/dry) |
|
Fire survival |
Standard (non-fire-rated); optional fire-resistant version available (BTTZ, BTTRZ) |
4. Thermal Response & Flame Behaviour. PVC insulation sustains a 70 °C continuous conductor temperature, with short-circuit capability up to 160 °C for ≤ 5 s. The cable is rated for service ambients between 0 °C and +70 °C and must not be installed below 0 °C (PVC becomes brittle). It is flame-retardant to GB/T 18380 / IEC 60332-1 (self-extinguishing). PVC contains halogen — not halogen-free; for low-smoke halogen-free earthing in public buildings, use WDZ-BYJ (also green-yellow striped) instead.
Fire Performance (BV — Standard)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
GB/T 18380.3 Category C (ZC), Category B (ZB) available |
|
Halogen content |
Contains halogen (PVC insulation) |
|
Smoke density |
Standard (non-low-smoke) |
|
Corrosivity |
Corrosive (PVC) |
|
Fire survival (circuit integrity) |
Not applicable (standard version); use mineral-insulated or fire-resistant building wire |
5. Installation Practice & Handling. Minimum bend radius is 4 × OD (≈ 14 mm) for fixed installation. The solid conductor is rigid and designed for fixed installation only. Install inside conduit, trunking, or wall conduit — do not leave exposed outdoors. Use earth lugs / socket PE terminals for low-resistance bonding. CRITICAL: green-yellow striped is PE ONLY — never use for phase, neutral, or control. Laying temperature must not fall below 0 °C.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 4 × OD → ≈ 14 mm at Ø3.5 mm |
static installation |
|
Max. pulling tension |
100 N |
solid Cu conductor, avoid sharp bends |
|
Conduit ID |
≥ 1.5 × OD → ≥ 5.3 mm; use 16 mm or 20 mm conduit |
standard building conduit |
|
Fixing |
cable clips, conduit, trunking |
— |
|
Impact resistance |
Low |
not armoured; protect with conduit |
|
Water resistance |
Poor |
indoor/dry locations only |
|
UV resistance |
Poor |
not for outdoor exposed use |
|
Termination note |
Strip insulation 10–12 mm; use standard copper lugs or screw terminals |
solid conductor requires careful handling to avoid breakage |
6. Typical Service Applications. This green-yellow BV-2.5 is the standard PE wire for: PE protective earthing, socket outlet earth terminals, distribution board PE busbar, equipment metal casing grounding, cable armour earthing, earth fault return path. Unlike solid green (used for specific bonding), green-yellow striped is the internationally recognised PE conductor — used for socket outlet earth terminals, distribution board PE bars, and equipment metal casing grounding. It is installed inside conduit or trunking — never outdoors.

7. Testing & Quality Assurance Regime. Routine tests on every coil include conductor DC resistance ≤ 7.41 Ω/km at 20 °C, the 2.0 kV AC / 5 min withstand, dimensional check (insulation ≥ 0.8 mm; OD ≈ 3.6 mm), and visual marking. Type tests include heat ageing (100 °C / 168 h), cold bend at 0 °C, heat shock at 150 °C, flame retardancy per GB/T 18380 / IEC 60332-1, insulation resistance, conductor continuity, and colour check (green-yellow striped per IEC 60446).
The Wire Parameters
| BV-2.5 mm² (green-yellow striped) — Copper PVC-Insulated Building Wire — Full Parameter Sheet | ||||
| Copper PVC-insulated building wire · solid Class 1 conductor / green-yellow striped PVC insulation · 450/750 V AC · PE protective earthing (IEC 60446 / GB 7947 standard colour) · GB/T 5023 / JB/T 8734 · finished Ø ≈ 3.6 mm | ||||
| Section | Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | ||||
| Cable type | BV (Copper PVC-insulated building wire) | — | PE protective earthing, single core | |
| Rated voltage (U0/U) | 450/750 | V AC | For building interior fixed wiring | |
| Number of cores | 1 × 2.5 | — | Single core | |
| Conductor material | Annealed solid copper | — | Class 1 solid per GB/T 3956 | |
| Insulation material | Polyvinyl chloride (PVC) | — | PVC-70 °C grade, green-yellow striped | |
| Outer sheath | None | — | Single-layer insulation, no outer sheath | |
| Colour | Green-yellow striped | — | PE protective earthing colour (IEC 60446 / GB 7947) | |
| Standard | GB/T 5023 / JB/T 8734 / GB 7947 | — | Chinese building wire + earthing colour standard | |
| 02 · Conductor (Solid Copper) | ||||
| Conductor type | Solid round copper wire | — | Class 1 solid per GB/T 3956 | |
| Conductor diameter | 1.78 | mm | Solid single wire | |
| Cross-sectional area | 2.5 | mm² | Nominal | |
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | Maximum per GB/T 3956 | |
| Conductor screen | None | — | LV building wire | |
| Conductor weight per km | ≈ 22 | kg/km | Copper density 8.89 g/cm³ | |
| 03 · Insulation (PVC) | ||||
| Insulation type | Polyvinyl chloride (PVC) | — | PVC-70 °C grade, green-yellow striped | |
| Insulation thickness | 0.8 | mm | Nominal | |
| Finished outer diameter | ≈ 3.6 | mm | 1.78 + 2×0.8 | |
| Colour | Green-yellow striped | — | PE protective earthing colour (IEC 60446 / GB 7947) | |
| Outer sheath | None | — | No outer sheath — insulation is the outer layer | |
| 04 · Electrical | ||||
| Rated voltage (AC) | 450/750 | V | For building interior fixed wiring | |
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | 2.5 mm² Cu Class 1 | |
| Insulation resistance | ≥ 0.011 | MΩ·km | PVC at 20 °C | |
| Conductor loss (at 24 A) | ≈ 4.3 | W/m | I²R at 70 °C | |
| Routine test voltage (AC) | 2.0 kV / 5 min | — | Power-frequency withstand | |
| Voltage test (AC) | 2.5 kV / 5 min | — | AC withstand test | |
| 05 · Thermal | ||||
| Max continuous conductor temp. | 70 | °C | PVC rated | |
| Short-circuit temp. | 160 | °C | PVC limit (≤ 5 s) | |
| Min installation temp. | 0 | °C | PVC becomes brittle below 0 °C | |
| Service ambient range | 0 to +70 | °C | Indoor dry locations | |
| UV resistance | None | — | Indoor use only — not UV resistant | |
| Ozone resistance | Limited | — | Indoor use only | |
| Halogen-free | No | — | PVC contains halogen | |
| Flame retardancy | IEC 60332-1 / GB/T 18380 | — | Self-extinguishing | |
| 06 · Mechanical | ||||
| Min bending radius (fixed) | ≥ 4 × OD ≈ 14 | mm | Fixed installation | |
| Tensile strength (insulation) | ≥ 10.0 | MPa | PVC insulation | |
| Abrasion resistance | Good | — | Indoor conduit / trunking | |
| Oil / fuel resistance | No | — | Indoor dry locations only | |
| 07 · Ampacity | ||||
| Air ampacity (open, 30 °C) | ≈ 24 | A | Single core, free air (est.) | |
| Conduit ampacity (3-core) | ≈ 19 | A | In conduit, grouped | |
| Voltage drop (per 100 m @ 24 A) | ≈ 1.8 | V | Single-phase loop ≈ 3.6 V | |
| 08 · Installation | ||||
| Laying methods | Conduit, trunking, wall conduit, PE busbar, socket earthing | — | Indoor fixed installation | |
| Connectors | Earth lugs, screw terminals, socket earth terminals | — | Standard earthing connections | |
| Polarity | Colour-coded | — | Green-yellow = PE only — must NOT be used for other purposes | |
| Special tools | Wire cutter, stripper, screwdriver | — | Standard electrical tools | |
| 09 · Packing | ||||
| Standard supply length | 100 m / coil | m | Building wire | |
| Reel / packing type | Coil / carton | — | Standard packaging | |
| Surface marking | BV, 2.5 mm², 450/750 V, GB/T 5023, metre marks | — | Continuous printing | |
| Storage conditions | Dry, indoor, 0 to +40 °C | — | Protect from UV / moisture | |
| 10 · Applications | ||||
| Typical use | PE protective earthing, socket outlet earth terminals, distribution board PE busbar, equipment metal casing grounding, cable armour earthing, earth fault return path | — | Indoor fixed wiring | |
| Max system voltage | 750 | V AC | 450/750 V rated | |
| Circuit current rating | Up to 24 | A | Per circuit breaker | |
The Wire Test Parameters
| Test Parameters — BV-2.5 mm² (green-yellow striped) | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | GB/T 3956, 20 °C | ≤ 7.41 Ω/km (2.5 mm² Cu) | Routine |
| 2 | Power-frequency withstand | 2.0 kV AC, 5 min | No breakdown | Routine |
| 3 | Thickness test | Micrometer | Insulation ≥ 0.8 mm | Routine |
| 4 | Dimensional check | Micrometer | OD ≈ 3.6 mm | Routine |
| 5 | Flame retardancy | GB/T 18380 / IEC 60332-1 | Self-extinguishing | Type |
| 6 | Heat ageing | 168 h at 100 °C | No cracking after bend test | Type |
| 7 | Cold bend test | 0 °C, mandrel 4×OD | No cracks | Type |
| 8 | Heat shock | 1 h at 150 °C | No cracking | Type |
| 9 | Insulation resistance | At 500 V DC, 20 °C | ≥ 0.011 MΩ·km | Type |
| 10 | Conductor continuity | Per GB/T 3956 | Solid continuous | Routine |
| 11 | Colour check | Visual | Green-yellow striped insulation (IEC 60446) | Routine |
| 12 | Marking check | Visual | BV, 2.5, 450/750 V printed | Routine |
The Wire Cross Section Structure

| BV-2.5 mm² (green-yellow striped) — Cross-Section Construction Diagram (Schematic) | |||||
| Building wire build-up: solid copper conductor → green-yellow striped PVC insulation · 450/750 V AC · finished Ø ≈ 3.6 mm · no outer sheath · PE protective earthing (IEC 60446) | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Conductor | Solid round annealed copper wire, Class 1 | — | 1.78 | PE protective earthing; R ≤ 7.41 Ω/km at 20 °C |
| 2 | Insulation | Polyvinyl chloride (PVC), green-yellow striped | 0.8 | ≈ 3.6 (finished) | Electrical insulation; 70 °C rated; IEC 60446 PE colour |
| 3 | (No sheath) | — | — | — | No outer sheath — insulation is the outer layer |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 3.6 | mm | 1.78 + 2×0.8 | ||
| Approx. cable mass | ≈ 22 | kg/km | Cu + PVC insulation | ||
| Nominal voltage rating | 450/750 | V AC | Building interior fixed wiring | ||
| Max continuous conductor temp. | 70 | °C | PVC rated | ||
| Short-circuit temp. (≤5 s) | 160 | °C | PVC limit | ||
| Min installation temp. | 0 | °C | PVC becomes brittle below 0 °C | ||
| Min bending radius | ≥ 4 × OD ≈ 14 | mm | Fixed installation | ||
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | 2.5 mm² Cu Class 1 | ||
| Insulation resistance | ≥ 0.011 | MΩ·km | PVC | ||
| Routine test voltage (AC) | 2.0 kV / 5 min | — | Power-frequency withstand | ||
| Air ampacity @ 30 °C | ≈ 24 | A | Single core, free air (est.) | ||
| Flame retardancy | GB/T 18380 / IEC 60332-1 | — | Self-extinguishing | ||
| Halogen-free | No | — | PVC contains halogen | ||
| UV resistance | None | — | Indoor use only | ||
| Schematic — not to exact scale. Finished Ø ≈ 3.6 mm and weight ≈ 22 kg/km from cross-referenced industry samples; conductor/insulation dimensions per GB/T 5023 and GB/T 3956; ampacity 24 A is an engineering estimate for single core in free air. BV is the standard Chinese building wire — solid copper conductor with PVC insulation, rated 450/750 V AC for interior fixed wiring. The green-yellow striped colour is the IEC 60446 / GB 7947 standard PE (protective earth) conductor colour and is reserved exclusively for protective earthing — it MUST NOT be used for any other purpose. Values marked (est.) require confirmation against the factory test certificate. | |||||
Construction Description
| Construction Description — BV-2.5 mm² (green-yellow striped) | |||
| Layer-by-layer building wire build-up · solid copper conductor / green-yellow striped PVC insulation · 450/750 V AC · finished Ø ≈ 3.6 mm · no outer sheath · PE protective earthing (IEC 60446 / GB 7947) | |||
| 1. Product Identity & Ratings | |||
| BV-2.5 (green-yellow striped) is the standard Chinese copper PVC-insulated building wire rated 450/750 V AC for interior fixed wiring, built and tested per GB/T 5023 / JB/T 8734. This is the IEC 60446 / GB 7947 standard **PE (protective earth) conductor colour** — green-yellow striped. Unlike solid green (used for specific bonding applications), green-yellow striped is reserved EXCLUSIVELY for protective earthing and must never be used for any other purpose (phase, neutral, control). Finished diameter is about 3.6 mm, mass about 22 kg/km, supplied in 100 m coils. | |||
| 2. Solid Copper Conductor | |||
| The 2.5 mm² conductor is a solid round annealed copper wire (Class 1) — a single 1.78 mm diameter wire, not stranded. This gives a maximum DC resistance of 7.41 Ω/km at 20 °C. The solid conductor is rigid and designed for fixed installation only — it should not be flexed repeatedly. For PE circuits, low loop resistance is critical to ensure protective devices operate during earth faults. | |||
| 3. Green-Yellow Striped PVC Insulation | |||
| The solid conductor is fully enclosed in a 0.8 mm layer of PVC with green-yellow diagonal stripes. This single layer provides both electrical insulation and the outer jacket — there is no separate outer sheath. The PVC is rated for 70 °C continuous conductor temperature (short-circuit up to 160 °C for ≤ 5 s). The green-yellow striped colour is the internationally recognised PE conductor colour per IEC 60446 / GB 7947, providing unmistakable visual identification of the protective earthing conductor. | |||
| 4. No Outer Sheath | |||
| Unlike power cables and PV cables, BV has no outer sheath — the PVC insulation IS the outer layer. This keeps the cable thin, light, and low-cost for building wiring. The insulation provides basic mechanical protection and electrical isolation, but the cable must be installed inside conduit, trunking, or wall conduit for additional mechanical protection. It is not suitable for direct burial or outdoor UV exposure. | |||
| 5. Site Handling & Operational Notes | |||
| • Install inside conduit, trunking, or wall conduit — do not leave exposed outdoors. • Observe the 4 × OD minimum bend radius (≈ 14 mm). • Service range 0 to +70 °C; conductor up to 70 °C continuous. • Routine test 2.0 kV AC / 5 min. • PVC contains halogen — not suitable for low-smoke halogen-free requirements (use WDZ-BYJ for LSZH). • At about 2.2 kg per 100 m, the cable is supplied in 100 m coils. • **CRITICAL: green-yellow striped is PE ONLY — never use for phase, neutral, or control.** • Use earth lugs / socket earth terminals for low-resistance bonding. |
8. Company Display



9. Packaging, Storage & Logistics. Standard delivery is 100 m per coil. Each coil carries continuous marking: BV, 2.5 mm², 450/750 V, GB/T 5023, supplier identity, production year, and sequential metre marks. Storage should be in dry, indoor premises at 0 to +40 °C, protected from UV and moisture.

10. Procurement Specification. State "BV-2.5 mm² green-yellow, 450/750 V" together with the required length. Always install inside conduit or trunking — never outdoors. For low-smoke halogen-free earthing in public buildings, specify WDZ-BYJ-2.5 green-yellow instead. Do not use green-yellow striped for any purpose other than PE protective earth. Use earth lugs / socket PE terminals for low-resistance
bonding.
11. Cable Industry FAQ.
- Q1: Why is green-yellow striped used for PE? The green-yellow diagonal stripe is the internationally recognised PE (protective earth) conductor colour per IEC 60446 / GB 7947. It provides unmistakable visual identification — you can always tell the earthing wire apart from phase and neutral conductors.
- Q2: What is the difference between green and green-yellow striped? Green-yellow striped is the IEC-standard PE conductor — reserved EXCLUSIVELY for protective earthing. Solid green may be used for specific bonding or earthing applications per local codes, but it is not the standard PE colour.
- Q3: Can I use green-yellow striped as a neutral? NO — absolutely not. Green-yellow striped is reserved for PE protective earth only. Using it as a neutral or phase conductor is a serious safety violation.
- Q4: What happens if I misidentify PE as a phase? If PE is accidentally used as a live conductor, the metal casing of electrical equipment will become live during an earth fault. The green-yellow stripe prevents this.
- Q5: What size PE conductor do I need? For 2.5 mm² phase conductors, the PE conductor may be the same size (2.5 mm²) if mechanically protected, or 4 mm² if unprotected. For larger phase conductors, see GB 16895 / IEC 60364-5-54.
- Q6: Can green-yellow striped be used for signal earthing? Yes — it is commonly used for equipment metal casing grounding and signal reference earthing.
- Q7: Why use solid copper instead of stranded? Solid copper (Class 1) is cheaper, stiffer, and ideal for fixed installation in conduit and trunking. It should not be flexed repeatedly — for flexing applications, use BVR (stranded flexible).
- Q8: Can BV be used outdoors? No — BV is designed for indoor dry locations only. The PVC insulation is not UV-resistant and will degrade when exposed to sunlight.
- Q9: What is the earth fault loop impedance? The PE conductor must have sufficiently low resistance to ensure the protective device (MCB/RCD) operates within the required time during an earth fault. This is calculated per GB 16895 / IEC 60364.
- Q10: What is the difference between PE and neutral? Neutral (blue) carries current under normal balanced conditions. PE (green-yellow) carries NO current under normal conditions — it only carries fault current during an earth fault. They must never be connected together.
- Q11: What earth lug should I use? Use standard copper earth lugs (crimp or screw type) sized for 2.5 mm² solid conductor. Ensure the lug is tightened to the correct torque and protected from corrosion.