2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant

2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
BV-2.5mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

Yellow Green BV 2.5mm² Ground Earth Wire PVC Insulated Copper Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or stranded)...

Product Details

Highlight:

2.5mm2 solid copper conductor

,

ground earth solid thhn

,

solid copper conductor ground earth

Conductor:
Copper (Cu), Class 1 Solid (typical For 2.5 Mm²) Or Class 2 Stranded, Nominal 1×∅1.78 Mm (solid) Or 7×∅0.68 Mm (stranded), Conductor Ø ≈ 1.78 Mm (solid)
Insulation:
PVC (polyvinyl Chloride), Nominal Thickness 0.8 Mm (typical), Colour: Red, Black, Blue, Yellow/green​ (available In Multiple Colours For Phase, Neutral, And Earth Identification)
Conductor nominal area:
2.5 Mm² (Cu)
Number of cores:
1
Conductor material:
Copper (Cu)
Conductor class:
Class 1 Solid (preferred) / Class 2 Stranded
Conductor construction:
1×∅1.78 Mm (solid, Typical) Or 7×∅0.68 Mm (stranded)
Conductor diameter (approx.):
1.78 Mm (solid)
Insulation thickness:
0.8 Mm
Overall cable diameter:
3.3 – 3.8 Mm
Design outer diameter:
≈ 3.5 Mm
Approx. weight:
0.028 – 0.035 Kg/m (28–35 Kg/km)
Design weight:
≈ 31 Kg/km
Cable shape:
Round

Product Description

Yellow Green BV 2.5mm² Ground Earth Wire PVC Insulated Copper Cable

Cable Designation & Meaning

 

Code

Meaning

B

Fixed wiring cable (Class B — building wire)

V

PVC (polyvinyl chloride) insulation

2.5 mm²

Nominal cross-sectional area of conductor

 

Construction: Plain copper conductor (solid or stranded), PVC insulation, single-core non-sheathed building wire.

Applicable Standards

  • GB/T 5023-2008 / IEC 60227 — Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V
  • GB/T 3956 / IEC 60228 — Conductors (Class 1 solid or Class 2 stranded, copper)
  • GB/T 18380 / IEC 60332 — Flame retardant tests
  • GB/T 2951 / IEC 60811 — Insulating and sheathing materials — Common test methods

2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant

BV-2.5 mm² (green-yellow striped, PE protective earth — IEC 60446 / GB 7947) — Copper PVC-Insulated Building Wire Specification & Engineering Data 

1. Product Overview & Rating Summary. BV-2.5 (green-yellow striped) is the standard Chinese copper PVC-insulated building wire rated 450/750 V AC for interior fixed wiring, built and tested per GB/T 5023 / JB/T 8734. This is the IEC 60446 / GB 7947 standard PE (protective earth) conductor colour — green-yellow diagonal stripes. Unlike solid green (used for specific bonding applications), green-yellow striped is reserved EXCLUSIVELY for protective earthing and must never be used for phase, neutral, or control circuits. Finished diameter is about 3.6 mm, mass about 22 kg/km, supplied in 100 m coils.

 

2. Layer-by-Layer Construction (Conductor to Outer).

Layer Construction Wall Diameter
Conductor Solid round annealed copper wire, Class 1 — 1.78 mm
Insulation Polyvinyl chloride (PVC), green-yellow striped 0.8 mm ≈ 3.6 mm (finished)
Outer sheath None — insulation is the outer layer — —

 

3. Electrical Characteristics. The 2.5 mm² conductor is a solid 1.78 mm annealed copper wire (Class 1, not stranded), giving a maximum DC resistance of 7.41 Ω/km at 20 °C. Routine proof is 2.0 kV AC / 5 minutes. Insulation resistance ≥ 0.011 MΩ·km. With the single core in free air at 30 °C, reference loading is about 24 A; in conduit with three grouped cores, the rating derates to about 19 A. For PE circuits, low loop resistance is critical to ensure protective devices operate during earth faults. Conductor loss at 24 A is about 4.3 W per metre at 70 °C.

Insulation Data

Property

Value

Material

PVC (polyvinyl chloride)

Nominal thickness

0.8 mm

Long-term service temp.

70 °C (continuous)

Short-circuit temp. (≤5 s)

160 °C​ (Cu conductor limit per IEC 60228)

Emergency overload temp.

90 °C (short term)

Weather resistance

Limited — for indoor/dry use only; not UV-resistant

Flame retardant

GB/T 18380.3 Category C (ZC) available; standard version passes IEC 60332-1

Smoke density

Standard (non-low-smoke)

Halogen content

Contains halogen (PVC)

Corrosivity

Corrosive (PVC)

Electrical Parameters

 

Parameter

Value

Note

Rated voltage U₀/U

450 / 750 V

GB/T 5023 / IEC 60227

Test voltage AC (50 Hz, 5 min)

2500 V

Routine test

DC resistance @20 °C

≤ 7.41 Ω/km

GB/T 3956 Class 1 max, 2.5 mm² (solid Cu)

AC resistance @70 °C (est.)

≈ 9.40 Ω/km

per core

Capacitance (approx.)

negligible

single-core building wire

Inductive reactance (approx.)

negligible

—

Current rating in conduit (30 °C ambient)

24 A​

single-phase, 2-core circuit (GB/T 16895)

Current rating in free air (30 °C)

27 A​

single cable

Current rating buried (20 °C)

22 A​

direct in soil (not recommended)

Short-circuit current (1 s, Cu, 160 °C)

≈ 0.25 kA (250 A)

2.5 mm² Cu

Frequency

50/60 Hz AC

—

Reference values: 2.5 mm² Cu at 24 A, single-phase 230 V → max load ≈ 5.5 kW. Voltage drop at 24 A ≈ 17.8 V/km per core (≈0.78% per 10 m at 230 V).

Temperature Characteristics

Property

Value

Max. conductor operating temp.

70 °C (continuous)

Max. short-circuit temp. (≤5 s)

160 °C (Cu conductor)

Emergency overload temp.

90 °C (short term)

Min. installation ambient temp.

0 °C (PVC insulation); below 0 °C pre-heating required

Service ambient range

−15 °C to +70 °C (indoor/dry)

Fire survival

Standard (non-fire-rated); optional fire-resistant version available (BTTZ, BTTRZ)

 

4. Thermal Response & Flame Behaviour. PVC insulation sustains a 70 °C continuous conductor temperature, with short-circuit capability up to 160 °C for ≤ 5 s. The cable is rated for service ambients between 0 °C and +70 °C and must not be installed below 0 °C (PVC becomes brittle). It is flame-retardant to GB/T 18380 / IEC 60332-1 (self-extinguishing). PVC contains halogen — not halogen-free; for low-smoke halogen-free earthing in public buildings, use WDZ-BYJ (also green-yellow striped) instead.

Fire Performance (BV — Standard)

Property

Value / Requirement

Flame retardant

GB/T 18380.3 Category C (ZC), Category B (ZB) available

Halogen content

Contains halogen (PVC insulation)

Smoke density

Standard (non-low-smoke)

Corrosivity

Corrosive (PVC)

Fire survival (circuit integrity)

Not applicable (standard version); use mineral-insulated or fire-resistant building wire

 

5. Installation Practice & Handling. Minimum bend radius is 4 × OD (≈ 14 mm) for fixed installation. The solid conductor is rigid and designed for fixed installation only. Install inside conduit, trunking, or wall conduit — do not leave exposed outdoors. Use earth lugs / socket PE terminals for low-resistance bonding. CRITICAL: green-yellow striped is PE ONLY — never use for phase, neutral, or control. Laying temperature must not fall below 0 °C.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 4 × OD → ≈ 14 mm at Ø3.5 mm

static installation

Max. pulling tension

100 N

solid Cu conductor, avoid sharp bends

Conduit ID

≥ 1.5 × OD → ≥ 5.3 mm; use 16 mm or 20 mm conduit

standard building conduit

Fixing

cable clips, conduit, trunking

—

Impact resistance

Low

not armoured; protect with conduit

Water resistance

Poor

indoor/dry locations only

UV resistance

Poor

not for outdoor exposed use

Termination note

Strip insulation 10–12 mm; use standard copper lugs or screw terminals

solid conductor requires careful handling to avoid breakage

 

6. Typical Service Applications. This green-yellow BV-2.5 is the standard PE wire for: PE protective earthing, socket outlet earth terminals, distribution board PE busbar, equipment metal casing grounding, cable armour earthing, earth fault return path. Unlike solid green (used for specific bonding), green-yellow striped is the internationally recognised PE conductor — used for socket outlet earth terminals, distribution board PE bars, and equipment metal casing grounding. It is installed inside conduit or trunking — never outdoors.

 

2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant

 

7. Testing & Quality Assurance Regime. Routine tests on every coil include conductor DC resistance ≤ 7.41 Ω/km at 20 °C, the 2.0 kV AC / 5 min withstand, dimensional check (insulation ≥ 0.8 mm; OD ≈ 3.6 mm), and visual marking. Type tests include heat ageing (100 °C / 168 h), cold bend at 0 °C, heat shock at 150 °C, flame retardancy per GB/T 18380 / IEC 60332-1, insulation resistance, conductor continuity, and colour check (green-yellow striped per IEC 60446).

 

The Wire Parameters

 

BV-2.5 mm² (green-yellow striped) — Copper PVC-Insulated Building Wire — Full Parameter Sheet 
Copper PVC-insulated building wire · solid Class 1 conductor / green-yellow striped PVC insulation · 450/750 V AC · PE protective earthing (IEC 60446 / GB 7947 standard colour) · GB/T 5023 / JB/T 8734 · finished Ø ≈ 3.6 mm
Section Parameter Value Unit Remarks / Standard
01 · Identification
  Cable type BV (Copper PVC-insulated building wire) — PE protective earthing, single core
  Rated voltage (U0/U) 450/750 V AC For building interior fixed wiring
  Number of cores 1 × 2.5 — Single core
  Conductor material Annealed solid copper — Class 1 solid per GB/T 3956
  Insulation material Polyvinyl chloride (PVC) — PVC-70 °C grade, green-yellow striped
  Outer sheath None — Single-layer insulation, no outer sheath
  Colour Green-yellow striped — PE protective earthing colour (IEC 60446 / GB 7947)
  Standard GB/T 5023 / JB/T 8734 / GB 7947 — Chinese building wire + earthing colour standard
02 · Conductor (Solid Copper)
  Conductor type Solid round copper wire — Class 1 solid per GB/T 3956
  Conductor diameter 1.78 mm Solid single wire
  Cross-sectional area 2.5 mm² Nominal
  DC resistance @ 20 °C ≤ 7.41 Ω/km Maximum per GB/T 3956
  Conductor screen None — LV building wire
  Conductor weight per km ≈ 22 kg/km Copper density 8.89 g/cm³
03 · Insulation (PVC)
  Insulation type Polyvinyl chloride (PVC) — PVC-70 °C grade, green-yellow striped
  Insulation thickness 0.8 mm Nominal
  Finished outer diameter ≈ 3.6 mm 1.78 + 2×0.8
  Colour Green-yellow striped — PE protective earthing colour (IEC 60446 / GB 7947)
  Outer sheath None — No outer sheath — insulation is the outer layer
04 · Electrical
  Rated voltage (AC) 450/750 V For building interior fixed wiring
  DC resistance @ 20 °C ≤ 7.41 Ω/km 2.5 mm² Cu Class 1
  Insulation resistance ≥ 0.011 MΩ·km PVC at 20 °C
  Conductor loss (at 24 A) ≈ 4.3 W/m I²R at 70 °C
  Routine test voltage (AC) 2.0 kV / 5 min — Power-frequency withstand
  Voltage test (AC) 2.5 kV / 5 min — AC withstand test
05 · Thermal
  Max continuous conductor temp. 70 °C PVC rated
  Short-circuit temp. 160 °C PVC limit (≤ 5 s)
  Min installation temp. 0 °C PVC becomes brittle below 0 °C
  Service ambient range 0 to +70 °C Indoor dry locations
  UV resistance None — Indoor use only — not UV resistant
  Ozone resistance Limited — Indoor use only
  Halogen-free No — PVC contains halogen
  Flame retardancy IEC 60332-1 / GB/T 18380 — Self-extinguishing
06 · Mechanical
  Min bending radius (fixed) ≥ 4 × OD ≈ 14 mm Fixed installation
  Tensile strength (insulation) ≥ 10.0 MPa PVC insulation
  Abrasion resistance Good — Indoor conduit / trunking
  Oil / fuel resistance No — Indoor dry locations only
07 · Ampacity
  Air ampacity (open, 30 °C) ≈ 24 A Single core, free air (est.)
  Conduit ampacity (3-core) ≈ 19 A In conduit, grouped
  Voltage drop (per 100 m @ 24 A) ≈ 1.8 V Single-phase loop ≈ 3.6 V
08 · Installation
  Laying methods Conduit, trunking, wall conduit, PE busbar, socket earthing — Indoor fixed installation
  Connectors Earth lugs, screw terminals, socket earth terminals — Standard earthing connections
  Polarity Colour-coded — Green-yellow = PE only — must NOT be used for other purposes
  Special tools Wire cutter, stripper, screwdriver — Standard electrical tools
09 · Packing
  Standard supply length 100 m / coil m Building wire
  Reel / packing type Coil / carton — Standard packaging
  Surface marking BV, 2.5 mm², 450/750 V, GB/T 5023, metre marks — Continuous printing
  Storage conditions Dry, indoor, 0 to +40 °C — Protect from UV / moisture
10 · Applications
  Typical use PE protective earthing, socket outlet earth terminals, distribution board PE busbar, equipment metal casing grounding, cable armour earthing, earth fault return path — Indoor fixed wiring
  Max system voltage 750 V AC 450/750 V rated
  Circuit current rating Up to 24 A Per circuit breaker

 

The Wire Test Parameters

 

Test Parameters — BV-2.5 mm² (green-yellow striped)
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 7.41 Ω/km (2.5 mm² Cu) Routine
2 Power-frequency withstand 2.0 kV AC, 5 min No breakdown Routine
3 Thickness test Micrometer Insulation ≥ 0.8 mm Routine
4 Dimensional check Micrometer OD ≈ 3.6 mm Routine
5 Flame retardancy GB/T 18380 / IEC 60332-1 Self-extinguishing Type
6 Heat ageing 168 h at 100 °C No cracking after bend test Type
7 Cold bend test 0 °C, mandrel 4×OD No cracks Type
8 Heat shock 1 h at 150 °C No cracking Type
9 Insulation resistance At 500 V DC, 20 °C ≥ 0.011 MΩ·km Type
10 Conductor continuity Per GB/T 3956 Solid continuous Routine
11 Colour check Visual Green-yellow striped insulation (IEC 60446) Routine
12 Marking check Visual BV, 2.5, 450/750 V printed Routine

 

The Wire Cross Section Structure

 

2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant

 

BV-2.5 mm² (green-yellow striped) — Cross-Section Construction Diagram (Schematic)
Building wire build-up: solid copper conductor → green-yellow striped PVC insulation · 450/750 V AC · finished Ø ≈ 3.6 mm · no outer sheath · PE protective earthing (IEC 60446)
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor Solid round annealed copper wire, Class 1 — 1.78 PE protective earthing; R ≤ 7.41 Ω/km at 20 °C
2 Insulation Polyvinyl chloride (PVC), green-yellow striped 0.8 ≈ 3.6 (finished) Electrical insulation; 70 °C rated; IEC 60446 PE colour
3 (No sheath) — — — No outer sheath — insulation is the outer layer
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 3.6 mm 1.78 + 2×0.8    
Approx. cable mass ≈ 22 kg/km Cu + PVC insulation    
Nominal voltage rating 450/750 V AC Building interior fixed wiring    
Max continuous conductor temp. 70 °C PVC rated    
Short-circuit temp. (≤5 s) 160 °C PVC limit    
Min installation temp. 0 °C PVC becomes brittle below 0 °C    
Min bending radius ≥ 4 × OD ≈ 14 mm Fixed installation    
DC resistance @ 20 °C ≤ 7.41 Ω/km 2.5 mm² Cu Class 1    
Insulation resistance ≥ 0.011 MΩ·km PVC    
Routine test voltage (AC) 2.0 kV / 5 min — Power-frequency withstand    
Air ampacity @ 30 °C ≈ 24 A Single core, free air (est.)    
Flame retardancy GB/T 18380 / IEC 60332-1 — Self-extinguishing    
Halogen-free No — PVC contains halogen    
UV resistance None — Indoor use only    
Schematic — not to exact scale. Finished Ø ≈ 3.6 mm and weight ≈ 22 kg/km from cross-referenced industry samples; conductor/insulation dimensions per GB/T 5023 and GB/T 3956; ampacity 24 A is an engineering estimate for single core in free air. BV is the standard Chinese building wire — solid copper conductor with PVC insulation, rated 450/750 V AC for interior fixed wiring. The green-yellow striped colour is the IEC 60446 / GB 7947 standard PE (protective earth) conductor colour and is reserved exclusively for protective earthing — it MUST NOT be used for any other purpose. Values marked (est.) require confirmation against the factory test certificate.

 

Construction Description

 

Construction Description — BV-2.5 mm² (green-yellow striped)
Layer-by-layer building wire build-up · solid copper conductor / green-yellow striped PVC insulation · 450/750 V AC · finished Ø ≈ 3.6 mm · no outer sheath · PE protective earthing (IEC 60446 / GB 7947)
1. Product Identity & Ratings
BV-2.5 (green-yellow striped) is the standard Chinese copper PVC-insulated building wire rated 450/750 V AC for interior fixed wiring, built and tested per GB/T 5023 / JB/T 8734. This is the IEC 60446 / GB 7947 standard **PE (protective earth) conductor colour** — green-yellow striped. Unlike solid green (used for specific bonding applications), green-yellow striped is reserved EXCLUSIVELY for protective earthing and must never be used for any other purpose (phase, neutral, control). Finished diameter is about 3.6 mm, mass about 22 kg/km, supplied in 100 m coils.
2. Solid Copper Conductor
The 2.5 mm² conductor is a solid round annealed copper wire (Class 1) — a single 1.78 mm diameter wire, not stranded. This gives a maximum DC resistance of 7.41 Ω/km at 20 °C. The solid conductor is rigid and designed for fixed installation only — it should not be flexed repeatedly. For PE circuits, low loop resistance is critical to ensure protective devices operate during earth faults.
3. Green-Yellow Striped PVC Insulation
The solid conductor is fully enclosed in a 0.8 mm layer of PVC with green-yellow diagonal stripes. This single layer provides both electrical insulation and the outer jacket — there is no separate outer sheath. The PVC is rated for 70 °C continuous conductor temperature (short-circuit up to 160 °C for ≤ 5 s). The green-yellow striped colour is the internationally recognised PE conductor colour per IEC 60446 / GB 7947, providing unmistakable visual identification of the protective earthing conductor.
4. No Outer Sheath
Unlike power cables and PV cables, BV has no outer sheath — the PVC insulation IS the outer layer. This keeps the cable thin, light, and low-cost for building wiring. The insulation provides basic mechanical protection and electrical isolation, but the cable must be installed inside conduit, trunking, or wall conduit for additional mechanical protection. It is not suitable for direct burial or outdoor UV exposure.
5. Site Handling & Operational Notes
• Install inside conduit, trunking, or wall conduit — do not leave exposed outdoors.  • Observe the 4 × OD minimum bend radius (≈ 14 mm).  • Service range 0 to +70 °C; conductor up to 70 °C continuous.  • Routine test 2.0 kV AC / 5 min.  • PVC contains halogen — not suitable for low-smoke halogen-free requirements (use WDZ-BYJ for LSZH).  • At about 2.2 kg per 100 m, the cable is supplied in 100 m coils.  • **CRITICAL: green-yellow striped is PE ONLY — never use for phase, neutral, or control.**  • Use earth lugs / socket earth terminals for low-resistance bonding.

 

8. Company Display

 

2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant

 

2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant

 

2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant

 

9. Packaging, Storage & Logistics. Standard delivery is 100 m per coil. Each coil carries continuous marking: BV, 2.5 mm², 450/750 V, GB/T 5023, supplier identity, production year, and sequential metre marks. Storage should be in dry, indoor premises at 0 to +40 °C, protected from UV and moisture.

 

2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant

 

10. Procurement Specification. State "BV-2.5 mm² green-yellow, 450/750 V" together with the required length. Always install inside conduit or trunking — never outdoors. For low-smoke halogen-free earthing in public buildings, specify WDZ-BYJ-2.5 green-yellow instead. Do not use green-yellow striped for any purpose other than PE protective earth. Use earth lugs / socket PE terminals for low-resistance

bonding.

 

11. Cable Industry FAQ.

  • Q1: Why is green-yellow striped used for PE? The green-yellow diagonal stripe is the internationally recognised PE (protective earth) conductor colour per IEC 60446 / GB 7947. It provides unmistakable visual identification — you can always tell the earthing wire apart from phase and neutral conductors.
  • Q2: What is the difference between green and green-yellow striped? Green-yellow striped is the IEC-standard PE conductor — reserved EXCLUSIVELY for protective earthing. Solid green may be used for specific bonding or earthing applications per local codes, but it is not the standard PE colour.
  • Q3: Can I use green-yellow striped as a neutral? NO — absolutely not. Green-yellow striped is reserved for PE protective earth only. Using it as a neutral or phase conductor is a serious safety violation.
  • Q4: What happens if I misidentify PE as a phase? If PE is accidentally used as a live conductor, the metal casing of electrical equipment will become live during an earth fault. The green-yellow stripe prevents this.
  • Q5: What size PE conductor do I need? For 2.5 mm² phase conductors, the PE conductor may be the same size (2.5 mm²) if mechanically protected, or 4 mm² if unprotected. For larger phase conductors, see GB 16895 / IEC 60364-5-54.
  • Q6: Can green-yellow striped be used for signal earthing? Yes — it is commonly used for equipment metal casing grounding and signal reference earthing.
  • Q7: Why use solid copper instead of stranded? Solid copper (Class 1) is cheaper, stiffer, and ideal for fixed installation in conduit and trunking. It should not be flexed repeatedly — for flexing applications, use BVR (stranded flexible).
  • Q8: Can BV be used outdoors? No — BV is designed for indoor dry locations only. The PVC insulation is not UV-resistant and will degrade when exposed to sunlight.
  • Q9: What is the earth fault loop impedance? The PE conductor must have sufficiently low resistance to ensure the protective device (MCB/RCD) operates within the required time during an earth fault. This is calculated per GB 16895 / IEC 60364.
  • Q10: What is the difference between PE and neutral? Neutral (blue) carries current under normal balanced conditions. PE (green-yellow) carries NO current under normal conditions — it only carries fault current during an earth fault. They must never be connected together.
  • Q11: What earth lug should I use? Use standard copper earth lugs (crimp or screw type) sized for 2.5 mm² solid conductor. Ensure the lug is tightened to the correct torque and protected from corrosion.