BV 2.5mm² Yellow Building Wire Solid Copper Single Core PVC Insulated 450/750V Fixed Power Wiring
Product Summary
Product Details
2.5mm² solid copper building wire
,PVC insulated single core wire
,450/750V fixed power wiring
Product Description
BV 2.5mm² Yellow Building Wire Solid Copper Single Core PVC Insulated 450/750V Fixed Power Wiring
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
B |
Building Wire |
|
V |
PVC insulation |
|
1×2.5 mm² |
Single core of 2.5 mm² copper conductor |
|
Yellow |
White PVC insulation (for civil indoor visible wiring) |
Construction: One 2.5 mm² solid copper conductor, white PVC insulation applied directly over the conductor.

BV 1×2.5 mm² (Yellow) — Single-Core PVC Insulated Copper Building Wire — Specification
1. Overview & Ratings
BV 1×2.5 (Yellow) is a 450/750 V single-core PVC insulated building wire built around one solid pure annealed copper conductor (bare, not tinned). The bright yellow insulation is selected where a phase or auxiliary conductor must stand out at a glance inside crowded junction boxes, panels and cable trays. A single 2.5 mm² copper wire carries each circuit; there is no braid, no inner sheath and no outer jacket. Finished OD ≈ 3.4 mm, ≈ 29 kg/km (est.), rated ampacity ≈ 20–25 A in conduit. Service range -15 to +70 °C. The yellow jacket serves identification first and protection second: it helps electricians trace the correct conductor before any terminal is opened. Designed for fixed indoor wiring only.
2. Construction Stack (Inner → Outer, expanded)
| Layer / Feature | Build | Function |
|---|---|---|
| Conductor | Pure annealed Cu, solid Class 1, Ø 1.78 mm | R ≤ 7.41 Ω/km, fixed wiring |
| Insulation | Yellow PVC ≈ 0.8 mm wall | 450/750 V dielectric, high-visibility phase ID |
| Shield | None | Single-core unshielded wire |
| Outer jacket | None | Insulation forms the outer layer |
3. Electrical Characteristics
DC resistance ≤ 7.41 Ω/km at 20 °C per GB/T 3956 Class 1 pure copper. Rated 450/750 V. Estimated load capacity ≈ 20–25 A in conduit at 30 °C, up to ≈ 32 A in free air, reduced when grouped in enclosures. Insulation resistance ≥ 20 MΩ·km. Each routine coil passes a 2000 V AC withstand test held 5 minutes. Typical capacitance ≈ 150 pF/m at 1 kHz. Because this wire runs one conductor per circuit, electrical identity is established by matching the yellow jacket and printed marking to the one-line diagram; live, neutral and earth are never assumed from colour alone without cross-checking the project schedule.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
White PVC (Type TI1 or TI2) |
|
Outer sheath material |
None (non-sheathed) |
|
Shield material |
None |
|
Long-term service temp. |
70 °C (continuous, TI1/TI2) |
|
Max. conductor temp. (normal) |
70 °C |
|
Short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Test voltage AC (5 min) |
2.5 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹² Ω·cm |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
450 / 750 V |
GB/T 5023.3 (fixed wiring) |
|
Max. system voltage |
500 V AC / 750 V DC |
— |
|
Test voltage AC (5 min) |
2.5 kV |
Routine test |
|
DC resistance @20 °C |
≤ 7.41 Ω/km |
GB/T 3956 Class 1 Cu max (2.5 mm²) |
|
AC resistance @70 °C (est.) |
≈ 9.28 Ω/km |
— |
|
Current rating in air (30 °C) |
24 A (reference, single-core open) |
typical residential |
|
Current rating in conduit (30 °C) |
20 A (reference, 2-core conduit) |
typical installation |
|
DC current capacity |
24 A |
— |
|
Short-circuit current (1 s, Cu, 160 °C) |
≈ 275 A |
— |
|
Capacitance (core-to-ambient, approx.) |
≈ 0.10 µF/km |
PVC |
|
Inductive reactance (approx.) |
≈ 0.10 Ω/km |
at 50 Hz (single-core) |
|
Frequency |
50/60 Hz AC, DC |
— |
Reference values: BV 2.5 (white) at 24 A, 230 V AC → max load ≈ 5,520 VA (typical lighting/socket circuit). At 24 V DC → max load ≈ 576 W.
4. Thermal & Flame Behaviour
Normal continuous operation -15 to +70 °C; short-circuit withstand up to 160 °C for up to 5 seconds. The yellow PVC compound meets IEC 60332-1 flame retardancy and self-extinguishes once the ignition source is removed. It is halogen-containing PVC, so in fires it releases HCl gas; avoid it in public, high-density or escape-route wiring where LSZH insulation is mandated. Bright pigment colours such as yellow are more prone to visible fading under prolonged direct sunlight, so the jacket should stay inside conduit, trunking or a closed tray. Bare copper contact should be kept in dry, enclosed locations only.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
70 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Min. installation ambient temp. |
−15 °C |
|
Service ambient range |
−15 °C to +70 °C |
|
Flexing temp. range |
Not recommended for flexing |
Fire Performance (BV — PVC, Non-Low-Smoke)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
GB/T 18380.3 / IEC 60332-3 (Category A/B/C as specified) |
|
Halogen content |
Contains halogen (PVC) |
|
Smoke density |
Not low-smoke (IEC 61034-2 not applicable) |
|
Corrosivity |
Corrosive (HCl emission from PVC) |
|
Toxicity |
Toxic fumes when burned (CO, HCl) |
|
EMI shielding |
None |
|
UV resistance |
Poor (PVC degrades outdoors, use conduit) |
|
Water resistance |
Limited (PVC insulation only) |
5. Installation Practice & Handling
Minimum bend radius ≥ 4×OD ≈ 14 mm. The solid Class 1 core is stiff and dimensionally stable; lay out straight runs with generous corner radii and avoid repeated bending back and forth. Strip the yellow jacket cleanly, seat the solid wire fully into the terminal block or lug, and tighten to the rated torque. Before connecting, verify on the one-line diagram whether this yellow conductor acts as the designated phase or auxiliary in that circuit. Route live, neutral and earth together in the same conduit; keep plain yellow separate from any green-yellow striped PE wire. After termination, record insulation resistance and continuity before energizing.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 4 × OD → ≈ 15 mm at Ø3.7 mm |
solid conductor |
|
Max. pulling tension |
150 N (2.5 mm² × 60 N/mm²) |
Cu conductor limit |
|
Direct burial |
Not recommended (PVC, no sheath, water ingress) |
— |
|
Surface mounting |
Conduit, trunking, surface-mounted wiring channel, DIN rail |
— |
|
Conduit ID |
≥ 16 mm (single), ≥ 20 mm (multiple) |
— |
|
Fixing |
cable clips, staples, trunking clips |
— |
|
Impact resistance |
Low (PVC) |
— |
|
Water resistance |
Limited (no sheath) |
— |
|
UV resistance |
Poor (indoor/conduit only) |
— |
|
Flex life |
Poor (Class 1 solid, NOT for flexing) |
— |
|
Termination note |
Screw terminals, compression lugs (2.5 mm²) |
— |
6. Typical Service Applications
Fixed indoor wiring across residential, commercial and light industrial installations: phase runs in lighting and socket circuits, branch feeders inside distribution boards, internal panel wiring, and auxiliary conductors in control cabinets. The yellow finish is particularly useful where conductors are bundled densely, where retrofit or troubleshooting access is frequent, or where the electrical contractor wants a high-visibility phase colour to ease handover and inspection. Accepted installation methods include conduit, trunking, cable tray and embedded wall wiring. It is unsuitable for: moving or trailing machine leads, shielded instrumentation signals, outdoor UV-exposed runs, submersible or buried circuits, and high-temperature heating elements.

7. Testing & Quality Assurance Regime
Routine tests on 100% of production: DC resistance, 2000 V/5 min AC withstand, insulation resistance, conductor construction, insulation thickness, dimensional inspection, dark-print legibility against the yellow jacket, mass per unit length, appearance and shade uniformity, and packing. Type tests per material batch or design change: heat aging at 100 °C for 7 days, cold bend at -15 °C, insulation tensile strength and elongation, flame retardancy, insulation flexibility, and wall thickness uniformity. Every coil ships with a mill test certificate plus ROHS and REACH declarations. Yellow lots are visually checked for even pigment dispersion, free from pale streaks or darker patches.
The Wire Parameters
| BV 1×2.5 mm² (Yellow) — Full Parameter Sheet | ||||
| Single-core yellow PVC insulated building wire · 450/750 V · pure annealed Cu solid Class 1 · yellow PVC insulation · no shield, no outer jacket · GB/T 5023 / IEC 60227 | ||||
| Section | Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | ||||
| Cable type | BV (Yellow) | — | Single-core, yellow PVC insulated, pure Cu conductor | |
| Rated voltage (U0/U) | 450/750 | V | Fixed indoor wiring | |
| Number of cores | 1 | — | Single core, solid | |
| Nominal cross-section | 2.5 | mm² | Per core, Class 1 solid | |
| Conductor material | Pure annealed copper (bare) | — | Class 1 per GB/T 3956, not tinned | |
| Insulation material | PVC (yellow) | — | 70 °C rated, 0.8 mm wall | |
| Shield | None | — | No braid / foil on single-core wire | |
| Outer jacket | None | — | Insulation forms the outer layer | |
| Standard reference | GB/T 5023 / IEC 60227 / JB/T 8734 | — | PVC insulated fixed wiring wire | |
| 02 · Conductor | ||||
| Conductor form | Solid (single wire) | — | Class 1 | |
| Conductor diameter | 1.78 | mm | Solid wire | |
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | Maximum per GB/T 3956 (pure Cu) | |
| Conductor surface | Bare pure copper | — | Not tinned; fixed indoor use | |
| 03 · Insulation | ||||
| Insulation type | PVC (yellow) | — | Soft PVC, 70 °C | |
| Insulation thickness | ≈ 0.8 | mm | Nominal | |
| Finished diameter | ≈ 3.4 | mm | Insulation outer Ø | |
| Insulation resistance | ≥ 20 | MΩ·km | At 20 °C | |
| 04 · Lay-Up & Shield | ||||
| Core lay-up | Not applicable | — | Single-core wire | |
| Filler / bedding | None | — | No inner sheath on BV | |
| Shield type | None | — | Unshielded building wire | |
| Shield coverage | — | — | Not applicable | |
| 05 · Insulation Finish | ||||
| Outer surface | Smooth yellow PVC extrusion | — | Uniform bright colour | |
| Printing | Designation / size / voltage / metre mark | — | Dark print at regular intervals | |
| Insulation colour | Yellow | — | Phase / auxiliary conductor; not PE green-yellow | |
| 06 · Electrical | ||||
| Rated voltage | 450/750 | V | Fixed wiring | |
| Test voltage (AC) | 2000 | V AC | 5 min routine | |
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | Per GB/T 3956 (pure Cu) | |
| Ampacity (conduit, est.) | ≈ 20–25 | A | 2.5 mm², 70 °C | |
| Ampacity (free air, est.) | Up to ≈ 32 | A | Derate for grouping / enclosure | |
| Capacitance | ≈ 150 | pF/m | At 1 kHz | |
| 07 · Thermal & Mechanical | ||||
| Max continuous conductor temp. | 70 | °C | Normal service | |
| Short-circuit temp. (≤5 s) | 160 | °C | Copper limit | |
| Min. ambient temp. | -15 | °C | Fixed installation | |
| Min. bending radius | ≥ 4 × OD ≈ 14 | mm | Fixed wiring, solid core | |
| Halogen content | Halogen-containing | — | PVC compound | |
| 08 · Flame & Environment | ||||
| Flame retardancy | IEC 60332-1 | — | Single vertical flame | |
| Oil resistance | Limited | — | PVC insulation | |
| UV resistance | Limited | — | Indoor / conduit use; yellow may fade in long sunlight | |
| Corrosion resistance | Limited (bare Cu) | — | Dry indoor only; use tinned variant for damp/outdoor | |
| ROHS / REACH | Compliant | — | EU 2011/65/EU | |
The Wire Test Parameters
| Test Parameters — BV 1×2.5 mm² (Yellow) | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | GB/T 3956, 20 °C | ≤ 7.41 Ω/km | Routine |
| 2 | AC voltage withstand | 2000 V AC, 5 min | No breakdown | Routine |
| 3 | Insulation resistance | 500 V megohmmeter | ≥ 20 MΩ·km | Routine |
| 4 | Conductor construction | Visual + micrometer | Solid Ø 1.78 mm pure Cu | Routine |
| 5 | Insulation thickness | Micrometer cross-section | ≈ 0.8 mm | Routine |
| 6 | Dimensional check | Caliper | OD ≈ 3.4 mm | Routine |
| 7 | Print legibility | Visual + rubbing | Dark print legible on yellow | Routine |
| 8 | Mass per unit length | Weighing | ≈ 29 kg/km | Routine |
| 9 | Appearance / colour | Visual | Smooth, uniform yellow, no streaks | Routine |
| 10 | Packing | Visual | Coil, sealed ends, labelled | Routine |
| 11 | Heat aging test | 7 days at 100 °C | Retention ≥ 70% | Type |
| 12 | Cold bend test | -15 °C, 4 h mandrel | No cracking | Type |
| 13 | Insulation tensile & elongation | Universal tester | Meets GB/T 5023 min. | Type |
| 14 | Flame retardancy | IEC 60332-1 | Self-extinguish | Type |
| 15 | Insulation flexibility | Mandrel bend at ambient | No cracking, no peeling | Type |
| 16 | Wall thickness uniformity | Micrometer at 4 points | Min. wall ≥ nominal − tolerance | Type |
Cross Section Structure

| BV 1×2.5 mm² (Yellow) — Cross-Section Construction Diagram (Schematic) | |||||
| Layered build-up: pure copper solid conductor (single core) → yellow PVC insulation · 450/750 V single-core PVC insulated building wire · high-visibility phase / auxiliary identification · no shield, no outer jacket · -15~+70 °C | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Conductor | Pure annealed copper, solid Class 1 — single wire Ø 1.78 mm | — | 1.78 | Fixed wiring; R ≤ 7.41 Ω/km; bare pure copper for high conductivity |
| 2 | Insulation | Yellow PVC compound, extruded over the solid conductor | ≈ 0.8 | ≈ 3.4 (finished) | Primary electrical insulation; 450/750 V rated; bright yellow aids fast phase-circuit identification |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 3.4 | mm | Single-core PVC building wire (est.) | ||
| Approximate cable mass | ≈ 29 | kg/km | Pure Cu + PVC insulation | ||
| Nominal voltage rating | 450/750 | V | Fixed indoor wiring | ||
| Max continuous conductor temp. | 70 | °C | Normal service | ||
| Min. ambient / installation temp. | -15 | °C | Fixed installation | ||
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | Class 1 pure copper, GB/T 3956 | ||
| Core count × cross-section | 1 × 2.5 | mm² | Single core, solid | ||
| Shielding | None | — | Single-core wire, no braid / foil | ||
| Insulation resistance | ≥ 20 | MΩ·km | PVC at 20 °C | ||
| Test voltage (AC) | 2000 V AC / 5 min | — | Routine withstand test | ||
| Flame retardancy | IEC 60332-1 | — | Single vertical flame | ||
| Insulation colour | Yellow (designated) | — | Phase / auxiliary conductor; not green-yellow PE | ||
| Jacket colour | — | — | BV has no outer jacket; insulation is the outer layer | ||
| Mass per 100 m | ≈ 2.9 | kg/100 m | For coil loading | ||
| Reference standard | GB/T 5023 / IEC 60227 / JB/T 8734 | — | PVC insulated fixed wiring wire | ||
| Schematic — not to exact scale. Finished Ø ≈ 3.4 mm and weight ≈ 29 kg/km from cross-referenced industry samples; solid pure copper conductor Ø 1.78 mm, 0.8 mm yellow PVC insulation. Pure copper (not tinned). Est. values confirmed against factory type certificate. | |||||
Construction Description
| Construction Description — BV 1×2.5 mm² (Yellow) | |||
| Layer-by-layer build-up narrative · 450/750 V single-core yellow PVC insulated building wire · GB/T 5023 / IEC 60227 · pure annealed copper solid conductor / yellow PVC insulation | |||
| 1. Product Identity & Ratings | |||
| BV 1×2.5 (Yellow) is a single-core PVC insulated building wire rated 450/750 V. The conductor is pure annealed bare copper (not tinned), chosen for high conductivity and stable long-term contact in fixed wiring. One 2.5 mm² solid copper core is covered by a continuous yellow PVC extrusion. There is no braid shield, no inner sheath and no outer jacket. OD ≈ 3.4 mm, ≈ 29 kg/km. Max 70 °C, -15 to +70 °C. The bright yellow finish gives a high-visibility phase or auxiliary conductor that stands out in crowded panels. | |||
| 2. Pure Copper Conductor | |||
| The 2.5 mm² conductor is a single solid annealed copper wire, Class 1, diameter 1.78 mm. Solid construction keeps the wire dimensionally stable and easy to seat in terminals and connectors. DC resistance ≤ 7.41 Ω/km at 20 °C per GB/T 3956. Pure bare copper provides the highest conductivity available for fixed installation; for damp or outdoor locations a tinned or insulated variant should be considered separately. | |||
| 3. Yellow PVC Insulation | |||
| A 0.8 mm yellow PVC compound is extruded continuously over the solid copper core, forming the only insulating and outer layer. The insulation provides the primary electrical barrier for 450/750 V circuits, with insulation resistance ≥ 20 MΩ·km at 20 °C. The bright yellow surface makes the conductor quick to trace during commissioning and maintenance; dark lettering is printed on the light jacket for legibility. | |||
| 4. Lay-Up & Colour Coding | |||
| As a single-core wire there is no stranding of multiple cores, fillers or bedding. In standard coding red denotes live/phase, blue neutral, green-yellow striped protective earth; plain yellow is widely assigned to a phase or auxiliary conductor under local practice. Plain yellow must never be confused with the green-yellow striped PE conductor, which is reserved for protective earthing only. | |||
| 5. Surface Marking & Application Range | |||
| The yellow insulation surface is printed at regular intervals with the designation BV, cross-section, voltage rating, manufacturer and metre mark; dark print remains legible against the light jacket. The wire is designed for fixed installation inside conduits, trunking and panel enclosures: lighting circuits, socket outlets, panel internal wiring and branch circuits. It is not a flexible appliance cable, not a shielded signal cable and not a submersible or direct-burial wire. |
8. Factory Advantages
Pure annealed solid copper gives stable conductivity and low resistance over long fixed runs. Continuous yellow PVC extrusion produces a smooth, consistent wall with a uniform bright shade and predictable diameter, without blisters or pinholes. Yellow is a standard stocked phase colour, which shortens lead times on general wiring orders. The light jacket takes a dark, high-contrast print that stays readable after installation. The solid core seats squarely in terminals, lowering the risk of loose joints. Every coil undergoes 100% routine electrical QA. Cut-to-length coils with sealed ends cut site waste. At ≈ 29 kg/km the wire stays light to pull through conduit. Full traceability is supported by MTC and certification packages for building-wiring tenders.

9. Packaging, Storage & Logistics
Cut to requested length on export-grade coils; both ends sealed against moisture. Coils are wrapped in waterproof film and cardboard, labelled with BV designation, cross-section, yellow colour, length, weight, production date and reel number. Common lengths 100/200/500/1000 m; custom cuts available. Store indoors at -10 to +40 °C, below 75% RH, away from sunlight, solvents and chemical vapours. Keep the film on until installation: bright yellow PVC shows surface scuffs and marks more readily than dark insulation, and long sun exposure dulls the pigment. Shipping terms FOB Shanghai/Nanjing/Qingdao; CIF and DAP on request. Sample lead 5–7 days, bulk 15–25 days. Different colours are packed and labelled in separate lots.

10. Procurement Specification
Order wording: "BV 1×2.5 pure copper, plain yellow insulation". Ask for the routine 2000 V AC withstand record and the DC resistance certificate for the specific yellow lot. Note this is a bare pure copper fixed-wiring variant for dry indoor use; for damp or outdoor service, select a tinned or appropriate insulated variant instead. Before ordering, confirm with the project colour schedule whether plain yellow is the assigned phase or auxiliary in that region — and never substitute it for the green-yellow striped protective earth conductor. State any regional certification requirements (CE, etc.) at order time. Terms: 30% T/T deposit, balance against B/L copy. Documents: MTC, ROHS/REACH, COO, commercial invoice, packing list.
11. Cable Industry FAQ
Q1: What does "BV" designate? B denotes copper conductor, V denotes PVC insulation; BV is the standard Chinese code for a single-core PVC insulated fixed-wiring wire, corresponding to plain building wire under IEC 60227 practice.
Q2: Why pick yellow insulation? Yellow is a high-visibility phase/auxiliary colour: the bright jacket lets staff trace the right conductor quickly in dense panels or trays, which helps commissioning, inspection and fault-finding.
Q3: Is yellow the protective earth wire? No. Protective earthing uses green-yellow striped insulation only. Plain yellow is a phase or auxiliary conductor; mixing the two violates wiring safety rules.
Q4: Solid or stranded conductor? Solid Class 1 pure annealed copper wire, Ø 1.78 mm; DC resistance ≤ 7.41 Ω/km at 20 °C.
Q5: What is the rated voltage? 450/750 V, intended for low-voltage fixed indoor lighting, socket and panel circuits.
Q6: How much current does 2.5 mm² carry? ≈ 20–25 A in conduit, up to ≈ 32 A in free air, derated for grouping and enclosure; match against local wiring rules and the upstream protective device.
Q7: Why pure copper rather than tinned? Bare pure copper offers the highest conductivity for dry indoor fixed contacts; tinned copper is normally reserved for damp or exposed locations where corrosion could attack bare copper.
Q8: Does yellow discolour in storage? Bright pigment can fade if left in direct sun, and scuffs show more easily than on dark PVC; keep coils wrapped and indoors until pull-in.
Q9: Is there any shielding on BV? None — BV is an unshielded single-core building wire. EMI-sensitive signal circuits call for a shielded RVVP multiconductor cable instead.
Q10: What certification ships with the coil? Routine 2000 V AC test record, DC resistance certificate and MTC, with shade uniformity noted on the appearance inspection.
Q11: When should BVR be chosen over BV? For frequent flexing, vibrating equipment connections or tight panel gaps, choose the stranded BVR variant; BV solid is best suited to straight, stationary fixed runs.