logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us

BV 2.5mm² Yellow Building Wire Solid Copper Single Core PVC Insulated 450/750V Fixed Power Wiring

BV 2.5mm² Yellow Building Wire Solid Copper Single Core PVC Insulated 450/750V Fixed Power Wiring

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
BV-2.5mm²

Trading Properties

moq
100 meters
unit price
USD 0.13-0.16/Meter
payment method
L/C,T/T
supply capacity
100000 rolls per month

Product Summary

BV 2.5mm² Yellow Building Wire Solid Copper Single Core PVC Insulated 450/750V Fixed Power Wiring Cable Designation & Meaning Code Meaning B Building Wire V PVC insulation 1×2.5 mm² Single core of 2.5 mm² copper conductor Yellow White PVC insulation (for civil indoor visible wiring) Construction: ...

Product Details

Highlight:

2.5mm² solid copper building wire

,

PVC insulated single core wire

,

450/750V fixed power wiring

Conductor nominal area:
2.5 Mm² (Cu) × 1
Number of cores:
1 (single-core)
Conductor material:
Copper (Cu)
Conductor class:
Class 1 Solid
Conductor construction:
1×∅1.78 Mm
Conductor diameter:
≈ 1.78 Mm
Insulation thickness (nom.):
0.8 Mm
Insulation thickness (min.):
0.62 Mm
Overall cable diameter:
3.2 – 4.2 Mm
Design outer diameter:
≈ 3.7 Mm
Approx. weight:
30 – 42 Kg/km
Design weight:
≈ 36 Kg/km
Cable shape:
Round

Product Description

BV 2.5mm² Yellow Building Wire Solid Copper Single Core PVC Insulated 450/750V Fixed Power Wiring

Cable Designation & Meaning

Code

Meaning

B

Building Wire

V

PVC insulation 

1×2.5 mm²

Single core of 2.5 mm² copper conductor

Yellow

White PVC insulation (for civil indoor visible wiring)


Construction: One 2.5 mm² solid copper conductor, white PVC insulation applied directly over the conductor.


BV 2.5mm² Yellow Building Wire Solid Copper Single Core PVC Insulated 450/750V Fixed Power Wiring

BV 1×2.5 mm² (Yellow) — Single-Core PVC Insulated Copper Building Wire — Specification 

1. Overview & Ratings

BV 1×2.5 (Yellow) is a 450/750 V single-core PVC insulated building wire built around one solid pure annealed copper conductor (bare, not tinned). The bright yellow insulation is selected where a phase or auxiliary conductor must stand out at a glance inside crowded junction boxes, panels and cable trays. A single 2.5 mm² copper wire carries each circuit; there is no braid, no inner sheath and no outer jacket. Finished OD ≈ 3.4 mm, ≈ 29 kg/km (est.), rated ampacity ≈ 20–25 A in conduit. Service range -15 to +70 °C. The yellow jacket serves identification first and protection second: it helps electricians trace the correct conductor before any terminal is opened. Designed for fixed indoor wiring only.

2. Construction Stack (Inner → Outer, expanded)

Layer / Feature Build Function
Conductor Pure annealed Cu, solid Class 1, Ø 1.78 mm R ≤ 7.41 Ω/km, fixed wiring
Insulation Yellow PVC ≈ 0.8 mm wall 450/750 V dielectric, high-visibility phase ID
Shield None Single-core unshielded wire
Outer jacket None Insulation forms the outer layer

3. Electrical Characteristics

DC resistance ≤ 7.41 Ω/km at 20 °C per GB/T 3956 Class 1 pure copper. Rated 450/750 V. Estimated load capacity ≈ 20–25 A in conduit at 30 °C, up to ≈ 32 A in free air, reduced when grouped in enclosures. Insulation resistance ≥ 20 MΩ·km. Each routine coil passes a 2000 V AC withstand test held 5 minutes. Typical capacitance ≈ 150 pF/m at 1 kHz. Because this wire runs one conductor per circuit, electrical identity is established by matching the yellow jacket and printed marking to the one-line diagram; live, neutral and earth are never assumed from colour alone without cross-checking the project schedule.

Insulation & Sheath Data

Property

Value

Insulation material

White PVC (Type TI1 or TI2)

Outer sheath material

None​ (non-sheathed)

Shield material

None​

Long-term service temp.

70 °C (continuous, TI1/TI2)

Max. conductor temp. (normal)

70 °C

Short-circuit temp. (≤5 s)

160 °C

Emergency overload temp.

100 °C (≤1 h)

Test voltage AC (5 min)

2.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹² Ω·cm

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

450 / 750 V

GB/T 5023.3 (fixed wiring)

Max. system voltage

500 V AC / 750 V DC

—

Test voltage AC (5 min)

2.5 kV

Routine test

DC resistance @20 °C

≤ 7.41 Ω/km

GB/T 3956 Class 1 Cu max (2.5 mm²)

AC resistance @70 °C (est.)

≈ 9.28 Ω/km

—

Current rating in air (30 °C)

24 A​ (reference, single-core open)

typical residential

Current rating in conduit (30 °C)

20 A​ (reference, 2-core conduit)

typical installation

DC current capacity

24 A​

—

Short-circuit current (1 s, Cu, 160 °C)

≈ 275 A

—

Capacitance (core-to-ambient, approx.)

≈ 0.10 µF/km

PVC

Inductive reactance (approx.)

≈ 0.10 Ω/km

at 50 Hz (single-core)

Frequency

50/60 Hz AC, DC

—


Reference values: BV 2.5 (white) at 24 A, 230 V AC → max load ≈ 5,520 VA​ (typical lighting/socket circuit). At 24 V DC → max load ≈ 576 W.

4. Thermal & Flame Behaviour

Normal continuous operation -15 to +70 °C; short-circuit withstand up to 160 °C for up to 5 seconds. The yellow PVC compound meets IEC 60332-1 flame retardancy and self-extinguishes once the ignition source is removed. It is halogen-containing PVC, so in fires it releases HCl gas; avoid it in public, high-density or escape-route wiring where LSZH insulation is mandated. Bright pigment colours such as yellow are more prone to visible fading under prolonged direct sunlight, so the jacket should stay inside conduit, trunking or a closed tray. Bare copper contact should be kept in dry, enclosed locations only.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

70 °C (continuous)

Max. short-circuit temp. (≤5 s)

160 °C

Emergency overload temp.

100 °C (≤1 h)

Min. installation ambient temp.

−15 °C

Service ambient range

−15 °C to +70 °C

Flexing temp. range

Not recommended for flexing


Fire Performance (BV — PVC, Non-Low-Smoke)

Property

Value / Requirement

Flame retardant

GB/T 18380.3 / IEC 60332-3​ (Category A/B/C as specified)

Halogen content

Contains halogen​ (PVC)

Smoke density

Not low-smoke​ (IEC 61034-2 not applicable)

Corrosivity

Corrosive​ (HCl emission from PVC)

Toxicity

Toxic fumes​ when burned (CO, HCl)

EMI shielding

None​

UV resistance

Poor​ (PVC degrades outdoors, use conduit)

Water resistance

Limited​ (PVC insulation only)

5. Installation Practice & Handling

Minimum bend radius ≥ 4×OD ≈ 14 mm. The solid Class 1 core is stiff and dimensionally stable; lay out straight runs with generous corner radii and avoid repeated bending back and forth. Strip the yellow jacket cleanly, seat the solid wire fully into the terminal block or lug, and tighten to the rated torque. Before connecting, verify on the one-line diagram whether this yellow conductor acts as the designated phase or auxiliary in that circuit. Route live, neutral and earth together in the same conduit; keep plain yellow separate from any green-yellow striped PE wire. After termination, record insulation resistance and continuity before energizing.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 4 × OD → ≈ 15 mm at Ø3.7 mm

solid conductor

Max. pulling tension

150 N (2.5 mm² × 60 N/mm²)

Cu conductor limit

Direct burial

Not recommended​ (PVC, no sheath, water ingress)

—

Surface mounting

Conduit, trunking, surface-mounted wiring channel, DIN rail

—

Conduit ID

≥ 16 mm (single), ≥ 20 mm (multiple)

—

Fixing

cable clips, staples, trunking clips

—

Impact resistance

Low (PVC)

—

Water resistance

Limited​ (no sheath)

—

UV resistance

Poor​ (indoor/conduit only)

—

Flex life

Poor​ (Class 1 solid, NOT for flexing)

—

Termination note

Screw terminals, compression lugs (2.5 mm²)

—


6. Typical Service Applications

Fixed indoor wiring across residential, commercial and light industrial installations: phase runs in lighting and socket circuits, branch feeders inside distribution boards, internal panel wiring, and auxiliary conductors in control cabinets. The yellow finish is particularly useful where conductors are bundled densely, where retrofit or troubleshooting access is frequent, or where the electrical contractor wants a high-visibility phase colour to ease handover and inspection. Accepted installation methods include conduit, trunking, cable tray and embedded wall wiring. It is unsuitable for: moving or trailing machine leads, shielded instrumentation signals, outdoor UV-exposed runs, submersible or buried circuits, and high-temperature heating elements.


BV 2.5mm² Yellow Building Wire Solid Copper Single Core PVC Insulated 450/750V Fixed Power Wiring

7. Testing & Quality Assurance Regime

Routine tests on 100% of production: DC resistance, 2000 V/5 min AC withstand, insulation resistance, conductor construction, insulation thickness, dimensional inspection, dark-print legibility against the yellow jacket, mass per unit length, appearance and shade uniformity, and packing. Type tests per material batch or design change: heat aging at 100 °C for 7 days, cold bend at -15 °C, insulation tensile strength and elongation, flame retardancy, insulation flexibility, and wall thickness uniformity. Every coil ships with a mill test certificate plus ROHS and REACH declarations. Yellow lots are visually checked for even pigment dispersion, free from pale streaks or darker patches.


The Wire Parameters


BV 1×2.5 mm² (Yellow) — Full Parameter Sheet
Single-core yellow PVC insulated building wire · 450/750 V · pure annealed Cu solid Class 1 · yellow PVC insulation · no shield, no outer jacket · GB/T 5023 / IEC 60227
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type BV (Yellow) — Single-core, yellow PVC insulated, pure Cu conductor

Rated voltage (U0/U) 450/750 V Fixed indoor wiring

Number of cores 1 — Single core, solid

Nominal cross-section 2.5 mm² Per core, Class 1 solid

Conductor material Pure annealed copper (bare) — Class 1 per GB/T 3956, not tinned

Insulation material PVC (yellow) — 70 °C rated, 0.8 mm wall

Shield None — No braid / foil on single-core wire

Outer jacket None — Insulation forms the outer layer

Standard reference GB/T 5023 / IEC 60227 / JB/T 8734 — PVC insulated fixed wiring wire
02 · Conductor

Conductor form Solid (single wire) — Class 1

Conductor diameter 1.78 mm Solid wire

DC resistance @ 20 °C ≤ 7.41 Ω/km Maximum per GB/T 3956 (pure Cu)

Conductor surface Bare pure copper — Not tinned; fixed indoor use
03 · Insulation

Insulation type PVC (yellow) — Soft PVC, 70 °C

Insulation thickness ≈ 0.8 mm Nominal

Finished diameter ≈ 3.4 mm Insulation outer Ø

Insulation resistance ≥ 20 MΩ·km At 20 °C
04 · Lay-Up & Shield

Core lay-up Not applicable — Single-core wire

Filler / bedding None — No inner sheath on BV

Shield type None — Unshielded building wire

Shield coverage — — Not applicable
05 · Insulation Finish

Outer surface Smooth yellow PVC extrusion — Uniform bright colour

Printing Designation / size / voltage / metre mark — Dark print at regular intervals

Insulation colour Yellow — Phase / auxiliary conductor; not PE green-yellow
06 · Electrical

Rated voltage 450/750 V Fixed wiring

Test voltage (AC) 2000 V AC 5 min routine

DC resistance @ 20 °C ≤ 7.41 Ω/km Per GB/T 3956 (pure Cu)

Ampacity (conduit, est.) ≈ 20–25 A 2.5 mm², 70 °C

Ampacity (free air, est.) Up to ≈ 32 A Derate for grouping / enclosure

Capacitance ≈ 150 pF/m At 1 kHz
07 · Thermal & Mechanical

Max continuous conductor temp. 70 °C Normal service

Short-circuit temp. (≤5 s) 160 °C Copper limit

Min. ambient temp. -15 °C Fixed installation

Min. bending radius ≥ 4 × OD ≈ 14 mm Fixed wiring, solid core

Halogen content Halogen-containing — PVC compound
08 · Flame & Environment

Flame retardancy IEC 60332-1 — Single vertical flame

Oil resistance Limited — PVC insulation

UV resistance Limited — Indoor / conduit use; yellow may fade in long sunlight

Corrosion resistance Limited (bare Cu) — Dry indoor only; use tinned variant for damp/outdoor

ROHS / REACH Compliant — EU 2011/65/EU


The Wire Test Parameters


Test Parameters — BV 1×2.5 mm² (Yellow)
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 7.41 Ω/km Routine
2 AC voltage withstand 2000 V AC, 5 min No breakdown Routine
3 Insulation resistance 500 V megohmmeter ≥ 20 MΩ·km Routine
4 Conductor construction Visual + micrometer Solid Ø 1.78 mm pure Cu Routine
5 Insulation thickness Micrometer cross-section ≈ 0.8 mm Routine
6 Dimensional check Caliper OD ≈ 3.4 mm Routine
7 Print legibility Visual + rubbing Dark print legible on yellow Routine
8 Mass per unit length Weighing ≈ 29 kg/km Routine
9 Appearance / colour Visual Smooth, uniform yellow, no streaks Routine
10 Packing Visual Coil, sealed ends, labelled Routine
11 Heat aging test 7 days at 100 °C Retention ≥ 70% Type
12 Cold bend test -15 °C, 4 h mandrel No cracking Type
13 Insulation tensile & elongation Universal tester Meets GB/T 5023 min. Type
14 Flame retardancy IEC 60332-1 Self-extinguish Type
15 Insulation flexibility Mandrel bend at ambient No cracking, no peeling Type
16 Wall thickness uniformity Micrometer at 4 points Min. wall ≥ nominal − tolerance Type


Cross Section Structure

BV 2.5mm² Yellow Building Wire Solid Copper Single Core PVC Insulated 450/750V Fixed Power Wiring

BV 1×2.5 mm² (Yellow) — Cross-Section Construction Diagram (Schematic)
Layered build-up: pure copper solid conductor (single core) → yellow PVC insulation · 450/750 V single-core PVC insulated building wire · high-visibility phase / auxiliary identification · no shield, no outer jacket · -15~+70 °C
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor Pure annealed copper, solid Class 1 — single wire Ø 1.78 mm — 1.78 Fixed wiring; R ≤ 7.41 Ω/km; bare pure copper for high conductivity
2 Insulation Yellow PVC compound, extruded over the solid conductor ≈ 0.8 ≈ 3.4 (finished) Primary electrical insulation; 450/750 V rated; bright yellow aids fast phase-circuit identification






Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 3.4 mm Single-core PVC building wire (est.)
Approximate cable mass ≈ 29 kg/km Pure Cu + PVC insulation
Nominal voltage rating 450/750 V Fixed indoor wiring
Max continuous conductor temp. 70 °C Normal service
Min. ambient / installation temp. -15 °C Fixed installation
DC resistance @ 20 °C ≤ 7.41 Ω/km Class 1 pure copper, GB/T 3956
Core count × cross-section 1 × 2.5 mm² Single core, solid
Shielding None — Single-core wire, no braid / foil
Insulation resistance ≥ 20 MΩ·km PVC at 20 °C
Test voltage (AC) 2000 V AC / 5 min — Routine withstand test
Flame retardancy IEC 60332-1 — Single vertical flame
Insulation colour Yellow (designated) — Phase / auxiliary conductor; not green-yellow PE
Jacket colour — — BV has no outer jacket; insulation is the outer layer
Mass per 100 m ≈ 2.9 kg/100 m For coil loading
Reference standard GB/T 5023 / IEC 60227 / JB/T 8734 — PVC insulated fixed wiring wire
Schematic — not to exact scale. Finished Ø ≈ 3.4 mm and weight ≈ 29 kg/km from cross-referenced industry samples; solid pure copper conductor Ø 1.78 mm, 0.8 mm yellow PVC insulation. Pure copper (not tinned). Est. values confirmed against factory type certificate.


Construction Description


Construction Description — BV 1×2.5 mm² (Yellow)
Layer-by-layer build-up narrative · 450/750 V single-core yellow PVC insulated building wire · GB/T 5023 / IEC 60227 · pure annealed copper solid conductor / yellow PVC insulation
1. Product Identity & Ratings
BV 1×2.5 (Yellow) is a single-core PVC insulated building wire rated 450/750 V. The conductor is pure annealed bare copper (not tinned), chosen for high conductivity and stable long-term contact in fixed wiring. One 2.5 mm² solid copper core is covered by a continuous yellow PVC extrusion. There is no braid shield, no inner sheath and no outer jacket. OD ≈ 3.4 mm, ≈ 29 kg/km. Max 70 °C, -15 to +70 °C. The bright yellow finish gives a high-visibility phase or auxiliary conductor that stands out in crowded panels.
2. Pure Copper Conductor
The 2.5 mm² conductor is a single solid annealed copper wire, Class 1, diameter 1.78 mm. Solid construction keeps the wire dimensionally stable and easy to seat in terminals and connectors. DC resistance ≤ 7.41 Ω/km at 20 °C per GB/T 3956. Pure bare copper provides the highest conductivity available for fixed installation; for damp or outdoor locations a tinned or insulated variant should be considered separately.
3. Yellow PVC Insulation
A 0.8 mm yellow PVC compound is extruded continuously over the solid copper core, forming the only insulating and outer layer. The insulation provides the primary electrical barrier for 450/750 V circuits, with insulation resistance ≥ 20 MΩ·km at 20 °C. The bright yellow surface makes the conductor quick to trace during commissioning and maintenance; dark lettering is printed on the light jacket for legibility.
4. Lay-Up & Colour Coding
As a single-core wire there is no stranding of multiple cores, fillers or bedding. In standard coding red denotes live/phase, blue neutral, green-yellow striped protective earth; plain yellow is widely assigned to a phase or auxiliary conductor under local practice. Plain yellow must never be confused with the green-yellow striped PE conductor, which is reserved for protective earthing only.
5. Surface Marking & Application Range
The yellow insulation surface is printed at regular intervals with the designation BV, cross-section, voltage rating, manufacturer and metre mark; dark print remains legible against the light jacket. The wire is designed for fixed installation inside conduits, trunking and panel enclosures: lighting circuits, socket outlets, panel internal wiring and branch circuits. It is not a flexible appliance cable, not a shielded signal cable and not a submersible or direct-burial wire.

8. Factory Advantages

Pure annealed solid copper gives stable conductivity and low resistance over long fixed runs. Continuous yellow PVC extrusion produces a smooth, consistent wall with a uniform bright shade and predictable diameter, without blisters or pinholes. Yellow is a standard stocked phase colour, which shortens lead times on general wiring orders. The light jacket takes a dark, high-contrast print that stays readable after installation. The solid core seats squarely in terminals, lowering the risk of loose joints. Every coil undergoes 100% routine electrical QA. Cut-to-length coils with sealed ends cut site waste. At ≈ 29 kg/km the wire stays light to pull through conduit. Full traceability is supported by MTC and certification packages for building-wiring tenders.


BV 2.5mm² Yellow Building Wire Solid Copper Single Core PVC Insulated 450/750V Fixed Power Wiring

9. Packaging, Storage & Logistics

Cut to requested length on export-grade coils; both ends sealed against moisture. Coils are wrapped in waterproof film and cardboard, labelled with BV designation, cross-section, yellow colour, length, weight, production date and reel number. Common lengths 100/200/500/1000 m; custom cuts available. Store indoors at -10 to +40 °C, below 75% RH, away from sunlight, solvents and chemical vapours. Keep the film on until installation: bright yellow PVC shows surface scuffs and marks more readily than dark insulation, and long sun exposure dulls the pigment. Shipping terms FOB Shanghai/Nanjing/Qingdao; CIF and DAP on request. Sample lead 5–7 days, bulk 15–25 days. Different colours are packed and labelled in separate lots.


BV 2.5mm² Yellow Building Wire Solid Copper Single Core PVC Insulated 450/750V Fixed Power Wiring

10. Procurement Specification

Order wording: "BV 1×2.5 pure copper, plain yellow insulation". Ask for the routine 2000 V AC withstand record and the DC resistance certificate for the specific yellow lot. Note this is a bare pure copper fixed-wiring variant for dry indoor use; for damp or outdoor service, select a tinned or appropriate insulated variant instead. Before ordering, confirm with the project colour schedule whether plain yellow is the assigned phase or auxiliary in that region — and never substitute it for the green-yellow striped protective earth conductor. State any regional certification requirements (CE, etc.) at order time. Terms: 30% T/T deposit, balance against B/L copy. Documents: MTC, ROHS/REACH, COO, commercial invoice, packing list.

11. Cable Industry FAQ

Q1: What does "BV" designate? B denotes copper conductor, V denotes PVC insulation; BV is the standard Chinese code for a single-core PVC insulated fixed-wiring wire, corresponding to plain building wire under IEC 60227 practice.

Q2: Why pick yellow insulation? Yellow is a high-visibility phase/auxiliary colour: the bright jacket lets staff trace the right conductor quickly in dense panels or trays, which helps commissioning, inspection and fault-finding.

Q3: Is yellow the protective earth wire? No. Protective earthing uses green-yellow striped insulation only. Plain yellow is a phase or auxiliary conductor; mixing the two violates wiring safety rules.

Q4: Solid or stranded conductor? Solid Class 1 pure annealed copper wire, Ø 1.78 mm; DC resistance ≤ 7.41 Ω/km at 20 °C.

Q5: What is the rated voltage? 450/750 V, intended for low-voltage fixed indoor lighting, socket and panel circuits.

Q6: How much current does 2.5 mm² carry? ≈ 20–25 A in conduit, up to ≈ 32 A in free air, derated for grouping and enclosure; match against local wiring rules and the upstream protective device.

Q7: Why pure copper rather than tinned? Bare pure copper offers the highest conductivity for dry indoor fixed contacts; tinned copper is normally reserved for damp or exposed locations where corrosion could attack bare copper.

Q8: Does yellow discolour in storage? Bright pigment can fade if left in direct sun, and scuffs show more easily than on dark PVC; keep coils wrapped and indoors until pull-in.

Q9: Is there any shielding on BV? None — BV is an unshielded single-core building wire. EMI-sensitive signal circuits call for a shielded RVVP multiconductor cable instead.

Q10: What certification ships with the coil? Routine 2000 V AC test record, DC resistance certificate and MTC, with shade uniformity noted on the appearance inspection.

Q11: When should BVR be chosen over BV? For frequent flexing, vibrating equipment connections or tight panel gaps, choose the stranded BVR variant; BV solid is best suited to straight, stationary fixed runs.