RVVB 2x2.5mm2 Flat Sheathed Wires Flexible Twin Stranded Copper Sheathed Cable
Product Summary
Product Details
RVVB flat sheathed wire
,2x2.5mm2 twin stranded copper cable
,flexible flat sheathed cable
Product Description
RVVB 2x2.5mm² Flat Flexible Twin Stranded Copper Sheathed Wire 300/500V Cable
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
R |
Flexible conductor (Class 5 fine-stranded) |
|
V |
PVC insulation |
|
V |
PVC sheath |
|
B |
Flat profile (twin parallel) |
|
2×2.5 mm² |
Two cores, each 2.5 mm² copper |
Construction: Two parallel fine-stranded flexible copper conductors, each PVC insulated, laid side-by-side and extruded with a common flat PVC outer sheath.
Applicable Standards
- GB/T 5023.5-2008 / IEC 60227-5 — Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V — Part 5: Flexible cables (cords)
- GB/T 3956 / IEC 60228 — Conductors (Class 5 flexible copper)
- GB/T 2951 / IEC 60811 — Insulating and sheathing materials — Common test methods
- GB/T 18380 / IEC 60332-1 — Flame retardant (single cable, passes)
- GB/T 5023.2-2008 / IEC 60227-2 — Test methods


RVVB-2×2.5 mm² — Flat PVC Sheathed Flexible Copper Connection Cable — Specification & Engineering Data
1. Overview & Ratings. RVVB-2×2.5 is a flat PVC sheathed flexible copper connection cable rated 300/500 V, 70 °C continuous. Built per GB/T 5023 / IEC 60227. It uses Class 5 fine-stranded copper conductors (~50×0.20 mm) for maximum flexibility — designed for appliance power leads, extension cords, and movable equipment. Finished flat dimensions ≈ 5.5×10.5 mm, ≈ 115 kg/km, 100 m coils.
2. Construction Stack (Conductor → Outer).
| Layer | Build | Wall | Dimensions |
|---|---|---|---|
| Flexible conductors (×2) | Fine-stranded annealed Cu, Class 5, 2×2.5 mm² | — | ≈ 2.0 mm each |
| PVC insulation (per core) | Polyvinyl chloride | ≈ 0.7 mm | ≈ 3.4 mm each |
| Flexible flat PVC sheath | Pliable PVC flat jacket | ≈ 1.5 mm | ≈ 5.5×10.5 mm (finished) |
3. Electrical Characteristics. DC resistance ≤ 7.41 Ω/km at 20 °C (flexible Cu 2.5 mm²); test voltage 2.0 kV AC / 5 min; insulation resistance ≥ 20 MΩ·km. Nominal ampacity ≈ 23 A (free air, 30 °C). Voltage drop ≈ 2.6 V/A·100 m.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
PVC (polyvinyl chloride), Type TI1/TI2 |
|
Outer sheath material |
PVC (polyvinyl chloride), Type TM1/TM2 |
|
Long-term service temp. |
70 °C (continuous, both insulation & sheath) |
|
Short-circuit temp. (≤5 s) |
160 °C (Cu conductor limit for PVC) |
|
Emergency overload temp. |
105 °C (short term) |
|
Test voltage AC (5 min) |
2.0 kV (routine test, 300/500 V class) |
|
Dielectric strength |
≥ 15 kV/mm (room temp.) |
|
Flex life |
≥ 20,000 bend cycles (typical, Class 5) |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
300 / 500 V |
GB/T 5023.5 / IEC 60227-5 |
|
Max. system voltage |
500 V AC |
— |
|
Test voltage AC (5 min) |
2.0 kV |
Routine test |
|
DC resistance @20 °C |
≤ 7.98 Ω/km |
GB/T 3956 Class 5 Cu max, 2.5 mm² |
|
AC resistance @70 °C (est.) |
≈ 10.1 Ω/km |
per core |
|
Current rating in air (30 °C) |
20 A |
2-core flat flexible, open air |
|
Current rating clipped to wall (30 °C) |
18 A |
surface-mounted |
|
Current rating in conduit (30 °C) |
16 A |
enclosed |
|
Short-circuit current (1 s, Cu, 160 °C) |
≈ 0.28 kA (280 A) |
2.5 mm² Cu |
|
Frequency |
50/60 Hz AC |
— |
Reference values: 2×2.5 mm² at 16–18 A, single-phase 230 V → max load ≈ 3.7–4.1 kW. Voltage drop at 18 A ≈ 182 V/km per core (≈7.9% per 100 m at 230 V — limit to ≤ 40 m run without upsize).
4. Thermal & Mechanical. 70 °C continuous conductor temperature; 160 °C short-circuit (≤ 5 s); ambient range −15~+70 °C. Bend ≥ 2 × OD ≈ 20 mm — very flexible. Resists metal fatigue from repeated bending and movement.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
70 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
160 °C (Cu conductor, PVC limit) |
|
Emergency overload temp. |
105 °C (not recommended for continuous) |
|
Min. installation ambient temp. |
0 °C (PVC); below 0 °C pre-heating required |
|
Service ambient range |
−15 °C to +70 °C (PVC insulation & sheath) |
|
Flexing temp. range |
+5 °C to +70 °C (recommended for repeated bending) |
|
Fire survival |
Standard (flame retardant single cable) |
Fire Performance (RVVB — Standard)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
IEC 60332-1 (single cable, passes) |
|
Halogen content |
Contains halogen (PVC insulation & sheath) |
|
Smoke density |
Standard (non-low-smoke) |
|
Corrosivity |
Corrosive (PVC) |
|
Fire survival (circuit integrity) |
Not applicable (standard version) |
5. Installation Practice & Handling. Designed for repeated bending and movement. Use ferrules at terminations to capture fine strands. At 115 kg/km, moderate weight. Indoor / appliance use only. Store dry.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 6 × cable thickness → ≈ 67 mm (at 11.2 mm H) |
flexible conductor, flat profile |
|
Max. pulling tension |
200 N |
fine-stranded Cu (handle gently) |
|
Direct burial |
Not recommended (no mechanical protection; use conduit) |
— |
|
Surface mounting |
Excellent (flat profile, clips to walls; flexible for routing around corners) |
cable clips every 200–300 mm |
|
Conduit ID |
≥ 16 mm |
use oval conduit for flat profile |
|
Fixing |
cable clips, trunking, conduit |
flat shape ideal for surface wiring |
|
Impact resistance |
Low (PVC sheath only) |
protect with conduit in exposed areas |
|
Water resistance |
Moisture-resistant (PVC) |
not waterproof; indoor dry areas preferred |
|
UV resistance |
Poor (PVC degrades in sunlight) |
indoor use only |
|
Flex life |
High (Class 5 fine-stranded, designed for occasional flexing) |
— |
|
Termination note |
Strip 10–12 mm sheath + 8–10 mm insulation; use standard screw terminals; ferrules recommended for fine-stranded conductors |
prevents strand splaying |
6. Typical Service Applications. Home appliance power leads, instrument interconnection, extension cords, small motor connections, movable equipment — where flexibility and repeated flexing are required.

7. Testing & QA Regime. Routine: conductor DC resistance, 2.0 kV AC / 5 min withstand, insulation resistance, dimensional check. Type: heating test, flexibility/bending test, flame retardancy, cold bend at −10 °C.
The Wire Parameters
| RVVB-2×2.5 mm² — Flat PVC Sheathed Flexible Copper Connection Cable — Full Parameter Sheet | ||||
| Flexible connection cable · 2× fine-stranded Cu conductors / PVC insulation / flexible flat PVC sheath · 300/500 V · 70 °C · ≈ 5.5 × 10.5 mm | ||||
| Section | Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | ||||
| Cable type | RVVB — flat PVC sheathed flexible copper connection cable | — | Flexible flat lead | |
| Rated voltage (U0/U) | 300/500 | V | Appliance / equipment | |
| Number of cores | 2 × 2.5 | — | 2-core (L/N) | |
| Conductor material | Annealed copper, fine-stranded | — | Class 5 flexible | |
| Insulation material | PVC (polyvinyl chloride) | — | Per core | |
| Sheath material | PVC (flexible flat, light) | — | Outer sheath | |
| Standard | GB/T 5023 / IEC 60227 | — | Flexible cord | |
| Application | Appliance leads, instrument wiring, extension cords | — | Flexible connection | |
| Shape | Flat (flexible) | — | RVVB = flexible flat | |
| 02 · Conductor (Flexible Cu) | ||||
| Conductor type | Fine-stranded annealed copper | — | Class 5 flexible | |
| Conductor area | 2 × 2.5 | mm² | 2-core flexible | |
| Stranding construction | ≈ 50 × 0.20 mm (approx.) | — | Very flexible | |
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | Cu 2.5 mm² flexible max | |
| Conductor weight per km | ≈ 48 | kg/km | 2×2.5 flexible Cu | |
| Conductor diameter | ≈ 2.0 | mm | Flexible stranded | |
| 03 · Insulation & Sheath | ||||
| Insulation type | PVC (per core) | — | General-purpose | |
| Insulation thickness | ≈ 0.7 | mm | 300/500 V | |
| Sheath type | PVC flexible flat sheath | — | Outer, pliable | |
| Sheath thickness | ≈ 1.5 | mm | Flat flexible | |
| Finished overall dimensions | ≈ 5.5 × 10.5 | mm | Flat rectangular | |
| Sheath color | Light (customizable) | — | Flexible | |
| 04 · Electrical | ||||
| Rated voltage (U0/U) | 300/500 | V | Flexible cord | |
| Max voltage | 500 | V | Phase-to-phase | |
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | Flexible Cu 2.5 mm² | |
| Insulation resistance | ≥ 20 | MΩ·km | PVC | |
| Test voltage (AC) | 2.0 kV / 5 min | — | Routine | |
| Nominal current (ampacity) | ≈ 23 | A | Free air, 30 °C | |
| Voltage drop per 100 m | ≈ 2.6 | V/A·100m | At 7.41 Ω/km | |
| 05 · Thermal | ||||
| Max conductor temp. | 70 | °C | PVC rated | |
| Short-circuit temp. | 160 | °C | Max 5 s | |
| Ambient range | -15 ~ +70 | °C | Indoor / appliance | |
| Laying temperature | ≥ -10 | °C | Flexible | |
| 06 · Mechanical | ||||
| Min bending radius (fixed) | ≥ 2 × OD ≈ 20 | mm | Very flexible | |
| Flexibility | Excellent | — | Class 5 fine strands | |
| Crush resistance | Moderate | — | Flexible sheath | |
| 07 · Installation | ||||
| Laying methods | Appliance leads, instrument connections, extension cords, movable equipment | — | Flexible connection | |
| Connectors | Crimp lugs / plug pins / screw terminals | — | Flexible cord | |
| Special tools | Wire stripper, crimping tool | — | Basic | |
| Bend radius | ≥ 2 × OD ≈ 20 mm | — | Very flexible | |
| 08 · Packing | ||||
| Standard supply length | 100 m / coil | m | Flexible cord | |
| Reel / packing type | Coil, wrapped | — | Plastic bag | |
| Surface marking | RVVB, 2×2.5, 300/500V, GB/T 5023, metre marks | — | Continuous printing | |
| Storage conditions | Dry, indoor | — | Protect from moisture | |
| 09 · Applications | ||||
| Typical use | Home appliance power leads, instrument interconnection, extension cords, small motor connections | — | Flexible connection | |
| Max system voltage | 500 | V | 300/500 V | |
| Application level | Low voltage | — | Appliance / equipment | |
| 10 · Core Identification | ||||
| Core 1 | Red / brown | — | Phase L | |
| Core 2 | Blue / light | — | Neutral N | |
| Sheath | Light / customizable | — | Outer flexible | |
| Earth | No earth core (2-core) | — | Add earth separately if needed | |
The Wire Test Parameters
| Test Parameters — RVVB-2×2.5 mm² Flexible Flat Sheathed Cable | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | GB/T 3956, 20 °C | ≤ 7.41 Ω/km (flexible Cu 2.5 mm²) | Routine |
| 2 | Voltage test (AC) | 2.0 kV AC, 5 min | No breakdown | Routine |
| 3 | Insulation resistance | 500 V DC | ≥ 20 MΩ·km | Routine |
| 4 | Insulation thickness | Micrometer | ≥ 0.7 mm per core | Routine |
| 5 | Heating test | 70 °C conductor, 2 h | No damage | Type |
| 6 | Flexibility / bending test | 2× OD, repeated cycles | No damage | Type |
| 7 | Flame retardancy | IEC 60332-1 | Self-extinguishing | Type |
| 8 | Dimensional check | Caliper | ≈ 5.5 × 10.5 mm flat | Routine |
| 9 | Conductor continuity | Per GB/T 3956 | Both flexible cores continuous | Routine |
| 10 | Cold bend test | -10 °C, bending | No cracking | Type |
| 11 | Sheath flexibility | Bend test | Sheath remains flexible | Type |
| 12 | Printing legibility | Visual | Marking readable | Routine |
The Wire Cross Section Structure

| RVVB-2×2.5 mm² — Cross-Section Construction Diagram (Schematic) | |||||
| Flexible flat sheathed: 2×fine-stranded Cu → PVC insulation → flexible flat PVC sheath · 300/500 V · 70 °C · ≈ 5.5 × 10.5 mm | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Dimensions (mm) | Function / Remarks |
| 1 | Flexible conductors (×2) | Fine-stranded annealed Cu, Class 5, 2 × 2.5 mm² | — | ≈ 2.0 each | R ≤ 7.41 Ω/km |
| 2 | PVC insulation (per core) | Polyvinyl chloride, general-purpose | ≈ 0.7 | ≈ 3.4 each | 300/500 V rated |
| 3 | Flexible flat PVC sheath | PVC, pliable flat jacket | ≈ 1.5 | ≈ 5.5 × 10.5 | Outer flexible protection |
| Key Dimensions & Properties (expanded) | |||||
| Finished flat dimensions | ≈ 5.5 × 10.5 | mm | Overall flexible flat | ||
| Approx. cable mass | ≈ 115 | kg/km | 2-core flexible flat | ||
| Nominal voltage rating | 300/500 | V | Appliance / equipment | ||
| Max conductor temp. | 70 | °C | PVC rated | ||
| Short-circuit temp. | 160 | °C | Max 5 s | ||
| Min bending radius (fixed) | ≥ 2 × OD ≈ 20 | mm | Very flexible | ||
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | Flexible Cu 2.5 mm² | ||
| Test voltage (AC) | 2.0 kV / 5 min | — | Routine | ||
| Nominal current (ampacity) | ≈ 23 | A | Free air, 30 °C | ||
| Number of cores | 2 | — | L + N | ||
| Conductor class | Class 5 (fine-stranded) | — | Flexible | ||
| Flexibility | Excellent | — | Appliance leads | ||
| Standard | GB/T 5023 / IEC 60227 | — | Flexible cord | ||
| Application | Appliance / instrument leads | — | Flexible connection | ||
| Schematic — not to exact scale. Finished flat dimensions ≈ 5.5×10.5 mm and weight ≈ 115 kg/km from cross-referenced industry samples. RVVB-2×2.5 is the flexible version of BVVB-2×2.5 — Class 5 fine-stranded copper conductors for appliance leads and movable equipment. Values marked (est.) require confirmation against the factory test certificate. | |||||
Construction Description
| Construction Description — RVVB-2×2.5 mm² flexible flat sheathed cable | |||
| Layer-by-layer flexible flat sheathed: 2×fine-stranded Cu / PVC insulation / flexible flat PVC sheath · 300/500 V · 70 °C · ≈ 5.5×10.5 mm | |||
| 1. Product Identity & Ratings | |||
| RVVB-2×2.5 is a flat PVC sheathed flexible copper connection cable rated 300/500 V, 70 °C continuous. Built per GB/T 5023 / IEC 60227. It uses Class 5 fine-stranded copper conductors for maximum flexibility — ideal for appliance power leads and movable equipment. Finished flat dimensions ≈ 5.5×10.5 mm, mass ≈ 115 kg/km, 100 m coils. | |||
| 2. Two Flexible Copper Conductors | |||
| Two 2.5 mm² fine-stranded annealed copper conductors (Class 5, ~50×0.20 mm each), laid side by side. DC resistance ≤ 7.41 Ω/km at 20 °C. The many tiny strands make the cable highly flexible and resistant to metal fatigue from repeated bending and movement. | |||
| 3. PVC Insulation & Flexible Flat Sheath | |||
| Each core has PVC insulation ≈ 0.7 mm thick. The two insulated cores are enclosed in a pliable flat PVC sheath ≈ 1.5 mm thick. The flexible sheath bends easily around corners and equipment, making RVVB suitable for moving or frequently connected devices. | |||
| 4. RVVB vs BVVB Difference | |||
| RVVB = flexible (R = soft). BVVB = rigid. RVVB uses Class 5 fine-stranded copper (~50×0.20 mm) vs BVVB's Class 2 stranded (19×0.41 mm). RVVB bends easier and resists fatigue, but has slightly higher resistance and costs more. Choose RVVB for appliance leads, extension cords, and movable equipment. | |||
| 5. Site Handling & Operational Notes | |||
| • Bend radius 2×OD (≈ 20 mm) — very flexible. • Designed for repeated bending / movement. • Use ferrules at terminations to capture fine strands. • At 115 kg/km, moderate weight. • Indoor / appliance use. • Store dry. |
8. Standards & Conformity. GB/T 5023 (PVC insulated cables); IEC 60227 (international equivalent); GB/T 3956 (Class 5 flexible conductors). Rated 300/500 V.
9. Packaging, Storage & Logistics. 100 m per coil, plastic wrapped. Continuous marking: RVVB, 2×2.5, 300/500V, GB/T 5023, metre marks. Store dry, indoor.

10. Procurement Specification. State "RVVB-2×2.5" + length. Confirm against factory test certificate.
11. Cable Industry FAQ.
- Q1: What does "RVVB" mean? R = flexible (soft); V = PVC insulation; V = PVC sheath; B = flat shape. It is a flat flexible sheathed connection cable.
- Q2: What is the difference between RVVB and BVVB? RVVB uses Class 5 fine-stranded copper (~50×0.20 mm) for maximum flexibility. BVVB uses Class 2 stranded copper (19×0.41 mm) for fixed installation. RVVB bends easier and resists fatigue, but costs more.
- Q3: When should I choose RVVB over BVVB? Choose RVVB for appliance leads, extension cords, and movable equipment that flex repeatedly. Choose BVVB for fixed wall-surface wiring that never moves.
- Q4: Why is the cable slightly larger and heavier? The fine-stranded flexible conductor has a larger effective diameter (~2.0 vs 1.78 mm) due to strand gaps, giving RVVB slightly larger flat dimensions (5.5×10.5 vs 5.0×10.0 mm) and higher weight (115 vs 105 kg/km).
- Q5: Can RVVB be surface-mounted on walls? Yes, but that is not its primary purpose. For fixed wall wiring, BVVB is more economical. RVVB is designed for flexible connection points.
- Q6: What is the ampacity? Approximately 23 A in free air at 30 °C. The flexible conductor has the same cross-section, so the ampacity matches BVVB.
- Q7: Does RVVB have an earth core? The 2-core version has only L + N. For earth, use RVVB-3×2.5 (3-core) or a separate earth wire.
- Q8: How do I terminate RVVB? Use ferrule terminals (cord-end sleeves) to fully capture the fine strands. This prevents stray strands and ensures reliable contact.
- Q9: Can RVVB be used outdoors? No — standard PVC sheath is not UV-resistant. For outdoor use, use outdoor-rated cable.
- Q10: Is RVVB fire-resistant? No — RVVB is general-purpose PVC. For fire circuits, use mineral-insulated fire cables.
- Q11: What is the bending radius? 2×OD ≈ 20 mm — very flexible. Designed for repeated flexing without conductor fatigue or breakage.