RVVB 2x2.5mm2 Flat Sheathed Wires Flexible Twin Stranded Copper Sheathed Cable

RVVB 2x2.5mm2 Flat Sheathed Wires Flexible Twin Stranded Copper Sheathed Cable

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
RVVB 2x2.5mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

RVVB 2x2.5mm² Flat Flexible Twin Stranded Copper Sheathed Wire 300/500V Cable Cable Designation & Meaning Code Meaning R Flexible conductor (Class 5 fine-stranded) V PVC insulation V PVC sheath B Flat profile (twin parallel) 2×2.5 mm² Two cores, each 2.5 mm² copper Construction: Two parallel fine...

Product Details

Conductor (×2):
Copper, Class 5 Fine-stranded Flexible, Nominal 35×∅0.30 Mm (2.5 Mm² Per Core), Conductor Ø ≈ 2.2–2.6 Mm
Copper, Class 5 fine-stranded flexible, nominal 35×∅0.30 mm (2.5 mm² per core), conductor Ø ≈ 2.2–2.:
PVC (polyvinyl Chloride)​ Compound, Nominal Thickness 0.8 Mm, Colour: Red​ (phase/live) And Blue​ (neutral)
Outer sheath:
Outer Sheath
Conductor nominal area:
2.5 Mm² (Cu)
Number of cores:
2
Conductor class:
Conductor Class
Conductor construction:
35×∅0.30 Mm (typical)
Conductor diameter (approx.):
2.2–2.6 Mm
Insulation thickness (per core):
0.8mm
Outer sheath thickness:
1.0mm
Overall cable dimensions:
≈ 6.8 × 11.0 Mm (flat Profile)
Design dimensions:
≈ 7.0 Mm (W) × 11.2 Mm (H)
Approx. weight:
0.095 – 0.115 Kg/m (95–115 Kg/km)
Conductor material:
Copper (Cu)
Design weight:
≈ 105 Kg/km
Cable shape:
Flat (twin Parallel)

Product Description

RVVB 2x2.5mm² Flat Flexible Twin Stranded Copper Sheathed Wire 300/500V Cable

Cable Designation & Meaning

 

Code

Meaning

R

Flexible conductor (Class 5 fine-stranded)

V

PVC insulation

V

PVC sheath

B

Flat profile (twin parallel)

2×2.5 mm²

Two cores, each 2.5 mm² copper

 

Construction: Two parallel fine-stranded flexible copper conductors, each PVC insulated, laid side-by-side and extruded with a common flat PVC outer sheath.

Applicable Standards

  • GB/T 5023.5-2008 / IEC 60227-5 — Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V — Part 5: Flexible cables (cords)
  • GB/T 3956 / IEC 60228 — Conductors (Class 5 flexible copper)
  • GB/T 2951 / IEC 60811 — Insulating and sheathing materials — Common test methods
  • GB/T 18380 / IEC 60332-1 — Flame retardant (single cable, passes)
  • GB/T 5023.2-2008 / IEC 60227-2 — Test methods

 

RVVB 2x2.5mm2 Flat Sheathed Wires Flexible Twin Stranded Copper Sheathed Cable

 

RVVB 2x2.5mm2 Flat Sheathed Wires Flexible Twin Stranded Copper Sheathed Cable

 

 

RVVB-2×2.5 mm² — Flat PVC Sheathed Flexible Copper Connection Cable — Specification & Engineering Data 

1. Overview & Ratings. RVVB-2×2.5 is a flat PVC sheathed flexible copper connection cable rated 300/500 V, 70 °C continuous. Built per GB/T 5023 / IEC 60227. It uses Class 5 fine-stranded copper conductors (~50×0.20 mm) for maximum flexibility — designed for appliance power leads, extension cords, and movable equipment. Finished flat dimensions ≈ 5.5×10.5 mm, ≈ 115 kg/km, 100 m coils.

 

2. Construction Stack (Conductor → Outer).

Layer Build Wall Dimensions
Flexible conductors (×2) Fine-stranded annealed Cu, Class 5, 2×2.5 mm² — ≈ 2.0 mm each
PVC insulation (per core) Polyvinyl chloride ≈ 0.7 mm ≈ 3.4 mm each
Flexible flat PVC sheath Pliable PVC flat jacket ≈ 1.5 mm ≈ 5.5×10.5 mm (finished)

 

3. Electrical Characteristics. DC resistance ≤ 7.41 Ω/km at 20 °C (flexible Cu 2.5 mm²); test voltage 2.0 kV AC / 5 min; insulation resistance ≥ 20 MΩ·km. Nominal ampacity ≈ 23 A (free air, 30 °C). Voltage drop ≈ 2.6 V/A·100 m.

Insulation & Sheath Data

Property

Value

Insulation material

PVC (polyvinyl chloride), Type TI1/TI2

Outer sheath material

PVC (polyvinyl chloride), Type TM1/TM2

Long-term service temp.

70 °C (continuous, both insulation & sheath)

Short-circuit temp. (≤5 s)

160 °C (Cu conductor limit for PVC)

Emergency overload temp.

105 °C (short term)

Test voltage AC (5 min)

2.0 kV (routine test, 300/500 V class)

Dielectric strength

≥ 15 kV/mm (room temp.)

Flex life

≥ 20,000 bend cycles (typical, Class 5)

Electrical Parameters

 

Parameter

Value

Note

Rated voltage U₀/U

300 / 500 V

GB/T 5023.5 / IEC 60227-5

Max. system voltage

500 V AC

—

Test voltage AC (5 min)

2.0 kV

Routine test

DC resistance @20 °C

≤ 7.98 Ω/km

GB/T 3956 Class 5 Cu max, 2.5 mm²

AC resistance @70 °C (est.)

≈ 10.1 Ω/km

per core

Current rating in air (30 °C)

20 A​

2-core flat flexible, open air

Current rating clipped to wall (30 °C)

18 A​

surface-mounted

Current rating in conduit (30 °C)

16 A​

enclosed

Short-circuit current (1 s, Cu, 160 °C)

≈ 0.28 kA (280 A)

2.5 mm² Cu

Frequency

50/60 Hz AC

—

Reference values: 2×2.5 mm² at 16–18 A, single-phase 230 V → max load ≈ 3.7–4.1 kW. Voltage drop at 18 A ≈ 182 V/km per core (≈7.9% per 100 m at 230 V — limit to ≤ 40 m run without upsize).

 

4. Thermal & Mechanical. 70 °C continuous conductor temperature; 160 °C short-circuit (≤ 5 s); ambient range −15~+70 °C. Bend ≥ 2 × OD ≈ 20 mm — very flexible. Resists metal fatigue from repeated bending and movement.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

70 °C (continuous)

Max. short-circuit temp. (≤5 s)

160 °C (Cu conductor, PVC limit)

Emergency overload temp.

105 °C (not recommended for continuous)

Min. installation ambient temp.

0 °C (PVC); below 0 °C pre-heating required

Service ambient range

−15 °C to +70 °C (PVC insulation & sheath)

Flexing temp. range

+5 °C to +70 °C (recommended for repeated bending)

Fire survival

Standard (flame retardant single cable)

Fire Performance (RVVB — Standard)

Property

Value / Requirement

Flame retardant

IEC 60332-1 (single cable, passes)

Halogen content

Contains halogen (PVC insulation & sheath)

Smoke density

Standard (non-low-smoke)

Corrosivity

Corrosive (PVC)

Fire survival (circuit integrity)

Not applicable (standard version)

 

5. Installation Practice & Handling. Designed for repeated bending and movement. Use ferrules at terminations to capture fine strands. At 115 kg/km, moderate weight. Indoor / appliance use only. Store dry.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 6 × cable thickness → ≈ 67 mm (at 11.2 mm H)

flexible conductor, flat profile

Max. pulling tension

200 N

fine-stranded Cu (handle gently)

Direct burial

Not recommended​ (no mechanical protection; use conduit)

—

Surface mounting

Excellent​ (flat profile, clips to walls; flexible for routing around corners)

cable clips every 200–300 mm

Conduit ID

≥ 16 mm

use oval conduit for flat profile

Fixing

cable clips, trunking, conduit

flat shape ideal for surface wiring

Impact resistance

Low (PVC sheath only)

protect with conduit in exposed areas

Water resistance

Moisture-resistant (PVC)

not waterproof; indoor dry areas preferred

UV resistance

Poor (PVC degrades in sunlight)

indoor use only

Flex life

High​ (Class 5 fine-stranded, designed for occasional flexing)

—

Termination note

Strip 10–12 mm sheath + 8–10 mm insulation; use standard screw terminals; ferrules recommended​ for fine-stranded conductors

prevents strand splaying

 

6. Typical Service Applications. Home appliance power leads, instrument interconnection, extension cords, small motor connections, movable equipment — where flexibility and repeated flexing are required.

 

RVVB 2x2.5mm2 Flat Sheathed Wires Flexible Twin Stranded Copper Sheathed Cable

 

7. Testing & QA Regime. Routine: conductor DC resistance, 2.0 kV AC / 5 min withstand, insulation resistance, dimensional check. Type: heating test, flexibility/bending test, flame retardancy, cold bend at −10 °C.

 

The Wire Parameters

 

RVVB-2×2.5 mm² — Flat PVC Sheathed Flexible Copper Connection Cable — Full Parameter Sheet 
Flexible connection cable · 2× fine-stranded Cu conductors / PVC insulation / flexible flat PVC sheath · 300/500 V · 70 °C · ≈ 5.5 × 10.5 mm
Section Parameter Value Unit Remarks / Standard
01 · Identification
  Cable type RVVB — flat PVC sheathed flexible copper connection cable — Flexible flat lead
  Rated voltage (U0/U) 300/500 V Appliance / equipment
  Number of cores 2 × 2.5 — 2-core (L/N)
  Conductor material Annealed copper, fine-stranded — Class 5 flexible
  Insulation material PVC (polyvinyl chloride) — Per core
  Sheath material PVC (flexible flat, light) — Outer sheath
  Standard GB/T 5023 / IEC 60227 — Flexible cord
  Application Appliance leads, instrument wiring, extension cords — Flexible connection
  Shape Flat (flexible) — RVVB = flexible flat
02 · Conductor (Flexible Cu)
  Conductor type Fine-stranded annealed copper — Class 5 flexible
  Conductor area 2 × 2.5 mm² 2-core flexible
  Stranding construction ≈ 50 × 0.20 mm (approx.) — Very flexible
  DC resistance @ 20 °C ≤ 7.41 Ω/km Cu 2.5 mm² flexible max
  Conductor weight per km ≈ 48 kg/km 2×2.5 flexible Cu
  Conductor diameter ≈ 2.0 mm Flexible stranded
03 · Insulation & Sheath
  Insulation type PVC (per core) — General-purpose
  Insulation thickness ≈ 0.7 mm 300/500 V
  Sheath type PVC flexible flat sheath — Outer, pliable
  Sheath thickness ≈ 1.5 mm Flat flexible
  Finished overall dimensions ≈ 5.5 × 10.5 mm Flat rectangular
  Sheath color Light (customizable) — Flexible
04 · Electrical
  Rated voltage (U0/U) 300/500 V Flexible cord
  Max voltage 500 V Phase-to-phase
  DC resistance @ 20 °C ≤ 7.41 Ω/km Flexible Cu 2.5 mm²
  Insulation resistance ≥ 20 MΩ·km PVC
  Test voltage (AC) 2.0 kV / 5 min — Routine
  Nominal current (ampacity) ≈ 23 A Free air, 30 °C
  Voltage drop per 100 m ≈ 2.6 V/A·100m At 7.41 Ω/km
05 · Thermal
  Max conductor temp. 70 °C PVC rated
  Short-circuit temp. 160 °C Max 5 s
  Ambient range -15 ~ +70 °C Indoor / appliance
  Laying temperature ≥ -10 °C Flexible
06 · Mechanical
  Min bending radius (fixed) ≥ 2 × OD ≈ 20 mm Very flexible
  Flexibility Excellent — Class 5 fine strands
  Crush resistance Moderate — Flexible sheath
07 · Installation
  Laying methods Appliance leads, instrument connections, extension cords, movable equipment — Flexible connection
  Connectors Crimp lugs / plug pins / screw terminals — Flexible cord
  Special tools Wire stripper, crimping tool — Basic
  Bend radius ≥ 2 × OD ≈ 20 mm — Very flexible
08 · Packing
  Standard supply length 100 m / coil m Flexible cord
  Reel / packing type Coil, wrapped — Plastic bag
  Surface marking RVVB, 2×2.5, 300/500V, GB/T 5023, metre marks — Continuous printing
  Storage conditions Dry, indoor — Protect from moisture
09 · Applications
  Typical use Home appliance power leads, instrument interconnection, extension cords, small motor connections — Flexible connection
  Max system voltage 500 V 300/500 V
  Application level Low voltage — Appliance / equipment
10 · Core Identification
  Core 1 Red / brown — Phase L
  Core 2 Blue / light — Neutral N
  Sheath Light / customizable — Outer flexible
  Earth No earth core (2-core) — Add earth separately if needed

 

The Wire Test Parameters

 

Test Parameters — RVVB-2×2.5 mm² Flexible Flat Sheathed Cable
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 7.41 Ω/km (flexible Cu 2.5 mm²) Routine
2 Voltage test (AC) 2.0 kV AC, 5 min No breakdown Routine
3 Insulation resistance 500 V DC ≥ 20 MΩ·km Routine
4 Insulation thickness Micrometer ≥ 0.7 mm per core Routine
5 Heating test 70 °C conductor, 2 h No damage Type
6 Flexibility / bending test 2× OD, repeated cycles No damage Type
7 Flame retardancy IEC 60332-1 Self-extinguishing Type
8 Dimensional check Caliper ≈ 5.5 × 10.5 mm flat Routine
9 Conductor continuity Per GB/T 3956 Both flexible cores continuous Routine
10 Cold bend test -10 °C, bending No cracking Type
11 Sheath flexibility Bend test Sheath remains flexible Type
12 Printing legibility Visual Marking readable Routine

 

The Wire Cross Section Structure

 

RVVB 2x2.5mm2 Flat Sheathed Wires Flexible Twin Stranded Copper Sheathed Cable

 

RVVB-2×2.5 mm² — Cross-Section Construction Diagram (Schematic)
Flexible flat sheathed: 2×fine-stranded Cu → PVC insulation → flexible flat PVC sheath · 300/500 V · 70 °C · ≈ 5.5 × 10.5 mm
No. Layer Material / Construction Nominal Thickness (mm) Dimensions (mm) Function / Remarks
1 Flexible conductors (×2) Fine-stranded annealed Cu, Class 5, 2 × 2.5 mm² — ≈ 2.0 each R ≤ 7.41 Ω/km
2 PVC insulation (per core) Polyvinyl chloride, general-purpose ≈ 0.7 ≈ 3.4 each 300/500 V rated
3 Flexible flat PVC sheath PVC, pliable flat jacket ≈ 1.5 ≈ 5.5 × 10.5 Outer flexible protection
Key Dimensions & Properties (expanded)
Finished flat dimensions ≈ 5.5 × 10.5 mm Overall flexible flat    
Approx. cable mass ≈ 115 kg/km 2-core flexible flat    
Nominal voltage rating 300/500 V Appliance / equipment    
Max conductor temp. 70 °C PVC rated    
Short-circuit temp. 160 °C Max 5 s    
Min bending radius (fixed) ≥ 2 × OD ≈ 20 mm Very flexible    
DC resistance @ 20 °C ≤ 7.41 Ω/km Flexible Cu 2.5 mm²    
Test voltage (AC) 2.0 kV / 5 min — Routine    
Nominal current (ampacity) ≈ 23 A Free air, 30 °C    
Number of cores 2 — L + N    
Conductor class Class 5 (fine-stranded) — Flexible    
Flexibility Excellent — Appliance leads    
Standard GB/T 5023 / IEC 60227 — Flexible cord    
Application Appliance / instrument leads — Flexible connection    
Schematic — not to exact scale. Finished flat dimensions ≈ 5.5×10.5 mm and weight ≈ 115 kg/km from cross-referenced industry samples. RVVB-2×2.5 is the flexible version of BVVB-2×2.5 — Class 5 fine-stranded copper conductors for appliance leads and movable equipment. Values marked (est.) require confirmation against the factory test certificate.

 

Construction Description

 

Construction Description — RVVB-2×2.5 mm² flexible flat sheathed cable
Layer-by-layer flexible flat sheathed: 2×fine-stranded Cu / PVC insulation / flexible flat PVC sheath · 300/500 V · 70 °C · ≈ 5.5×10.5 mm
1. Product Identity & Ratings
RVVB-2×2.5 is a flat PVC sheathed flexible copper connection cable rated 300/500 V, 70 °C continuous. Built per GB/T 5023 / IEC 60227. It uses Class 5 fine-stranded copper conductors for maximum flexibility — ideal for appliance power leads and movable equipment. Finished flat dimensions ≈ 5.5×10.5 mm, mass ≈ 115 kg/km, 100 m coils.
2. Two Flexible Copper Conductors
Two 2.5 mm² fine-stranded annealed copper conductors (Class 5, ~50×0.20 mm each), laid side by side. DC resistance ≤ 7.41 Ω/km at 20 °C. The many tiny strands make the cable highly flexible and resistant to metal fatigue from repeated bending and movement.
3. PVC Insulation & Flexible Flat Sheath
Each core has PVC insulation ≈ 0.7 mm thick. The two insulated cores are enclosed in a pliable flat PVC sheath ≈ 1.5 mm thick. The flexible sheath bends easily around corners and equipment, making RVVB suitable for moving or frequently connected devices.
4. RVVB vs BVVB Difference
RVVB = flexible (R = soft). BVVB = rigid. RVVB uses Class 5 fine-stranded copper (~50×0.20 mm) vs BVVB's Class 2 stranded (19×0.41 mm). RVVB bends easier and resists fatigue, but has slightly higher resistance and costs more. Choose RVVB for appliance leads, extension cords, and movable equipment.
5. Site Handling & Operational Notes
• Bend radius 2×OD (≈ 20 mm) — very flexible.  • Designed for repeated bending / movement.  • Use ferrules at terminations to capture fine strands.  • At 115 kg/km, moderate weight.  • Indoor / appliance use.  • Store dry.

 

 

8. Standards & Conformity. GB/T 5023 (PVC insulated cables); IEC 60227 (international equivalent); GB/T 3956 (Class 5 flexible conductors). Rated 300/500 V.

 

9. Packaging, Storage & Logistics. 100 m per coil, plastic wrapped. Continuous marking: RVVB, 2×2.5, 300/500V, GB/T 5023, metre marks. Store dry, indoor.

 

RVVB 2x2.5mm2 Flat Sheathed Wires Flexible Twin Stranded Copper Sheathed Cable

 

10. Procurement Specification. State "RVVB-2×2.5" + length. Confirm against factory test certificate.

 

11. Cable Industry FAQ.

  • Q1: What does "RVVB" mean? R = flexible (soft); V = PVC insulation; V = PVC sheath; B = flat shape. It is a flat flexible sheathed connection cable.
  • Q2: What is the difference between RVVB and BVVB? RVVB uses Class 5 fine-stranded copper (~50×0.20 mm) for maximum flexibility. BVVB uses Class 2 stranded copper (19×0.41 mm) for fixed installation. RVVB bends easier and resists fatigue, but costs more.
  • Q3: When should I choose RVVB over BVVB? Choose RVVB for appliance leads, extension cords, and movable equipment that flex repeatedly. Choose BVVB for fixed wall-surface wiring that never moves.
  • Q4: Why is the cable slightly larger and heavier? The fine-stranded flexible conductor has a larger effective diameter (~2.0 vs 1.78 mm) due to strand gaps, giving RVVB slightly larger flat dimensions (5.5×10.5 vs 5.0×10.0 mm) and higher weight (115 vs 105 kg/km).
  • Q5: Can RVVB be surface-mounted on walls? Yes, but that is not its primary purpose. For fixed wall wiring, BVVB is more economical. RVVB is designed for flexible connection points.
  • Q6: What is the ampacity? Approximately 23 A in free air at 30 °C. The flexible conductor has the same cross-section, so the ampacity matches BVVB.
  • Q7: Does RVVB have an earth core? The 2-core version has only L + N. For earth, use RVVB-3×2.5 (3-core) or a separate earth wire.
  • Q8: How do I terminate RVVB? Use ferrule terminals (cord-end sleeves) to fully capture the fine strands. This prevents stray strands and ensures reliable contact.
  • Q9: Can RVVB be used outdoors? No — standard PVC sheath is not UV-resistant. For outdoor use, use outdoor-rated cable.
  • Q10: Is RVVB fire-resistant? No — RVVB is general-purpose PVC. For fire circuits, use mineral-insulated fire cables.
  • Q11: What is the bending radius? 2×OD ≈ 20 mm — very flexible. Designed for repeated flexing without conductor fatigue or breakage.