DC (PV) Solar Cable H1Z2Z2-K 4.0 mm² Single Core Tinned Copper XLPE/XLPO Insulated
Basic Properties
Trading Properties
Product Summary
Product Details
h1z2z2-k solar array cable
,h1z2z2-k photovoltaic solar cable
,xlpo solar array cable
Product Description
DC (PV) Solar Cable H1Z2Z2-K 4.0 mm² Single Core Tinned Copper XLPE/XLPO Insulated
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
H |
Harmonised cable (European standard) |
|
1Z2Z2 |
Double insulation, halogen-free, heat-resistant, UV-resistant |
|
K |
Flexible conductor (fine-stranded) |
|
4.0 mm² |
Nominal cross-sectional area of conductor |
Construction: One 4.0 mm² tinned copper conductor, inner layer of XLPO insulation, outer layer of XLPO sheath (same material, double-layer extrusion). No metallic screen/armour.
Applicable Standards
- EN 50618:2014 — Photovoltaic cables — Double insulated cables for use in photovoltaic systems
- IEC 62930 — Electric cables for photovoltaic systems (single-core)
- EN 60228 / IEC 60228 — Conductors of insulated cables (Class 5 flexible)
- EN 60332-1-2 / IEC 60332-1-2 — Flame propagation test (single cable)
- EN 61034-2 / IEC 61034-2 — Smoke density (low-smoke)
- EN 60754-1/2 / IEC 60754-1/2 — Halogen gas emission (halogen-free)
- EN 50305 — Railway applications (fire performance reference)

H1Z2Z2-K 4.0 mm² — Solar Photovoltaic Flexible DC Cable — Specification
1. Overview & Ratings. H1Z2Z2-K 4.0 is a single-core flexible PV DC cable rated 1.5 kV: one 4.0 mm² tinned annealed copper core (Class 5/6) insulated and jacketed by two layers of irradiated cross-linked polyolefin (XLPO). OD ≈ 6.5 mm, ≈ 55 kg/km (est.), ≈ 35 A (est.). UV-, ozone- and weather-resistant, -40~+90 °C. Scope: PV module strings, DC runs to combiner boxes and the inverter DC side — not mains AC and not a fire-rated circuit.
2. Construction Stack (Inner → Outer, expanded).
| Layer / Feature | Build | Function |
|---|---|---|
| Conductor | 1×4.0 tinned Cu, Class 5/6, ≈56/0.30 strands | R ≤5.09 Ω/km, anti-corrosion |
| Insulation | Cross-linked polyolefin ≈0.9 mm | DC dielectric, UV rated |
| Sheath | Cross-linked polyolefin ≈0.9 mm | Outer weather jacket |
| Wall total | Double layer ≈1.8 mm | UV/ozone protection |
| Color | Red (+) / black (−) | PV DC polarity coding |
3. Electrical Characteristics. R ≤5.09 Ω/km @20 °C; 1.5 kV DC; ≈35 A (est., free air); high and stable insulation resistance; 90 °C max conductor; DC side only.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
XLPO (electron-beam cross-linked polyolefin) |
|
Sheath material |
XLPO (electron-beam cross-linked polyolefin) |
|
Long-term service temp. |
−40 °C to +120 °C (continuous) |
|
Max. conductor temp. (normal) |
120 °C |
|
Short-circuit temp. (≤5 s) |
280 °C |
|
Emergency overload temp. |
150 °C (≤1 h) |
|
Test voltage AC (50 Hz, 5 min) |
6.5 kV |
|
Test voltage DC |
15 kV |
|
Dielectric strength |
≥ 30 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹⁴ Ω·cm |
|
Weather resistance |
Excellent (UV, ozone, moisture) |
|
Halogen content |
Zero halogen (EN 60754-1/2) |
|
Shield |
None |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage DC |
1.5 kV DC (max. system voltage) |
EN 50618 |
|
Rated voltage AC (U₀/U) |
0.6 / 1 kV AC |
reference only (PV is DC) |
|
Max. system voltage |
1,500 V DC (IEC 62930) / 1,000 V DC (EN 50618) |
— |
|
Test voltage AC (5 min) |
6.5 kV |
Type test |
|
DC resistance @20 °C |
≤ 4.91 Ω/km |
EN 60228 Class 5 Cu/Sn max (4.0 mm²) |
|
AC resistance @120 °C (est.) |
≈ 7.20 Ω/km |
— |
|
Current rating in free air (60 °C ambient) |
55 A (DC, single cable) |
EN 50618 reference method |
|
Current rating in free air (30 °C ambient) |
~65 A (DC, extrapolated) |
— |
|
Current rating in conduit (30 °C) |
~50 A (DC) |
— |
|
Current rating (PV array, 70 °C avg.) |
~45 A (DC, conservative design) |
typical PV installation |
|
DC current capacity |
55 A (rated, 60 °C ambient) |
— |
|
Short-circuit current (1 s, Cu, 280 °C) |
≈ 440 A |
— |
|
Capacitance (core-to-sheath, approx.) |
≈ 0.08 µF/km |
XLPO |
|
Inductive reactance (approx.) |
≈ 0.08 Ω/km |
at 50 Hz |
|
Frequency |
DC (photovoltaic application) |
— |
Reference values: H1Z2Z2-K 4.0 at 55 A DC, 1,000 V → max DC power ≈ 55 kW per conductor (single-core). In a typical PV string (600–1,000 V DC, 10–15 A per string), this cable is oversized for string cabling and suitable for combiner box feeds, inverter DC input, and array main trunk circuits.
4. Thermal & Weather. -40~+90 °C continuous; UV, ozone and weather resistant for rooftop and ground-mount exposure; flame-retardant option — ordinary PV cable, not 950 °C fire-rated.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
120 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
280 °C |
|
Emergency overload temp. |
150 °C (≤1 h) |
|
Min. installation ambient temp. |
−40 °C |
|
Service ambient range |
−40 °C to +120 °C |
|
Flexing temp. range |
−40 °C to +120 °C |
Fire Performance (H1Z2Z2-K — Halogen-Free, Low-Smoke, Flame Retardant)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
EN 60332-1-2 / IEC 60332-1-2 (single cable, self-extinguishing) |
|
Flame retardant class |
Category C (typical, per EN 50618) |
|
Halogen content |
Zero halogen (EN 60754-1/2) |
|
Smoke density |
Low-smoke (EN 61034-2, light transmittance ≥ 60%) |
|
Corrosivity |
Non-corrosive (EN 60754-2) |
|
Toxicity |
Low toxicity (no halogen acids) |
|
EMI shielding |
None |
|
UV resistance |
Excellent (EN 50618, HD 605) |
|
Ozone resistance |
Excellent (EN 50396) |
|
Weather resistance |
Excellent (outdoor, 25-year design life) |
5. Installation Practice & Handling. Bend ≥ 6×OD ≈ 39 mm; use qualified PV connectors; observe red/black polarity; fix on racks with UV-resistant clips; insulation test after install.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 4 × OD → ≈ 24 mm at Ø6.1 mm |
flexible cable |
|
Max. pulling tension |
60 N (4.0 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Suitable (with UV-resistant XLPO, direct burial rated) |
— |
|
Surface mounting |
Cable tray, conduit, cable clips, tie wraps |
— |
|
Conduit ID |
≥ 16 mm |
— |
|
Fixing |
cable ties, PV cable clips |
— |
|
Impact resistance |
Medium (XLPO) |
— |
|
Water resistance |
Excellent (XLPO, moisture-resistant) |
— |
|
UV resistance |
Excellent (25-year outdoor service) |
— |
|
Flex life |
Excellent (Class 5 fine-stranded) |
flexible / routing |
|
Termination note |
MC4 connectors (crimp), screw terminals, compression lugs |
— |
|
Stripping |
Easy (XLPO, no adhesion to conductor) |
— |
6. Typical Service Applications. PV module strings, DC runs, combiner boxes and the inverter DC side on rooftop and ground-mount solar arrays.

7. Testing & QA Regime (16 items). Routine: DC resistance, DC voltage test, insulation resistance, conductor construction, wall thickness, dimensional check, print legibility, mass, appearance, packing. Type: bending, UV aging, heat aging, cold bend, jacket tensile, flame.
Cable Parameters
| H1Z2Z2-K 1×4.0 mm² — Harmonised Photovoltaic DC Cable — Full Parameter Sheet | ||||
| Harmonised PV cable · tinned copper flexible conductor (Class 5) / double-layer halogen-free cross-linked insulation + sheath · 0.6/1.0 kV DC · IEC 60332-1 · HAR certified · per EN 50618 / HD 6036 · finished Ø ≈ 5.1 mm | ||||
| Section | Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | ||||
| Cable type | H1Z2Z2-K (harmonised PV cable) | — | Harmonised European PV cable, single core, flexible | |
| Rated voltage (U0/U) | 0.6/1.0 | kV | DC; for PV array interconnection | |
| Number of cores | 1 × 4.0 | — | Single core (one + and one − per string) | |
| Conductor material | Tinned annealed copper | — | Class 5 flexible per EN 60228 | |
| Insulation material | Halogen-free cross-linked polyethylene (XLPE) | — | Z2 = halogen-free, UV/ozone resistant | |
| Outer sheath material | Halogen-free cross-linked polyolefin | — | Z2 = halogen-free, weather jacket | |
| Flame retardancy | IEC 60332-1 (single-cable vertical flame) | — | Single-cable self-extinguishing | |
| Certification | HAR (harmonised) | — | EN 50618 / HD 6036 harmonised standard | |
| 02 · Conductor (Tinned Copper) | ||||
| Stranding — 4.0 mm² | Flexible stranded tinned copper | — | Class 5 per EN 60228 | |
| Strand count (typical) | 56 × 0.30 | mm | Tinned copper wires | |
| Conductor diameter | ≈ 2.5 | mm | After stranding (est.) | |
| DC resistance @ 20 °C | ≤ 4.49 | Ω/km | Maximum per EN 60228 Class 5 | |
| Conductor screen | None | — | LV DC cable | |
| Conductor weight per km | ≈ 42 | kg/km | Copper density 8.89 g/cm³ | |
| 03 · Insulation & Sheath (Double-Layer) | ||||
| Inner insulation type | Halogen-free cross-linked polyethylene (XLPE) | — | Z2 = halogen-free | |
| Inner insulation thickness | 0.8 | mm | Nominal | |
| Outer sheath type | Halogen-free cross-linked polyolefin | — | Z2 = halogen-free weather jacket | |
| Outer sheath thickness | 0.8 | mm | Nominal | |
| Finished outer diameter | ≈ 5.1 | mm | 2.5 + 2×0.8 + 2×0.8 | |
| Colour | Black (standard) | — | UV-resistant carbon-black | |
| 04 · Electrical | ||||
| Rated voltage (DC) | 0.6/1.0 | kV | Max system voltage 1.8 kV DC | |
| DC resistance @ 20 °C | ≤ 4.49 | Ω/km | 4.0 mm² Cu Class 5 | |
| Insulation resistance | ≥ 200 | MΩ·km | XLPE at 20 °C | |
| Conductor loss (at 45 A) | ≈ 2.9 | W/m | I²R at 90 °C | |
| Routine test voltage (AC) | 3.5 kV / 5 min | — | Power-frequency withstand | |
| Voltage test (DC) | 6.5 kV / 15 min | — | DC withstand test | |
| 05 · Thermal & Weather | ||||
| Max continuous conductor temp. | 90 | °C | Standard rated | |
| Short-circuit temp. (≤ 5 s) | 250 | °C | XLPE limit | |
| Min installation temp. | -40 | °C | Cold-bend test | |
| Service ambient range | -40 to +90 | °C | European / temperate climates | |
| UV resistance | 1000 h UV preconditioning | — | Per EN 50618 | |
| Ozone resistance | Yes | — | Tested per EN 50618 | |
| Halogen-free | Yes | — | Z2 = halogen-free (IEC 60754) | |
| Flame retardancy | IEC 60332-1 (single-cable) | — | Vertical flame, self-extinguishing | |
| 06 · Mechanical | ||||
| Min bending radius (fixed) | ≥ 4 × OD ≈ 20 | mm | Flexible cable | |
| Min bending radius (flexing) | ≥ 6 × OD ≈ 31 | mm | If repeatedly moved | |
| Tensile strength (insulation) | ≥ 15.0 | MPa | After ageing at 135 °C | |
| Abrasion resistance | Yes | — | Tinned strands resist oxidation | |
| Oil / fuel resistance | Limited | — | Avoid prolonged contact | |
| 07 · Ampacity | ||||
| Air ampacity (open, 30 °C) | ≈ 45 | A | Single core, free air | |
| Air ampacity (open, 60 °C) | ≈ 35 | A | Derating at high ambient | |
| Voltage drop (per 100 m @ 45 A) | ≈ 2.0 | V | Two-pole loop ≈ 4.0 V | |
| 08 · Installation | ||||
| Laying methods | Rooftop PV, ground-mount, cable tray, conduit | — | European PV installations | |
| Connectors | PV4 / MC4-type | — | Crimped with dedicated tool | |
| Polarity | Marked on sheath | — | + / − printed along length | |
| Special tools | PV crimper, cable cutter, torque wrench | — | MC4 connectors require dedicated tool | |
| 09 · Packing | ||||
| Standard supply length | 100 m / coil (retail) | m | European DIY / residential PV | |
| Reel / packing type | Coil (residential) / drum (utility) | — | Sealed ends against moisture | |
| Surface marking | H1Z2Z2-K, 1×4.0, 0.6/1.0 kV, +/−, HAR, metre marks, year | — | Continuous printing | |
| Storage conditions | Dry, covered, −20 to +40 °C | — | Protect from UV during storage | |
| 10 · Applications | ||||
| Typical use | European rooftop PV, residential / commercial PV, utility-scale PV, ground-mount PV, barn / agricultural PV | — | European / temperate climates | |
| Max system voltage | 1.8 | kV DC | Open-circuit Voc at lowest temp | |
| String current rating | Up to 45 | A | Per string fusing | |
Cable Test Parameters
| Test Parameters — H1Z2Z2-K 1×4.0 mm² (double-layer halogen-free) | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | EN 60228, 20 °C | ≤ 4.49 Ω/km (4.0 mm² Cu) | Routine |
| 2 | Power-frequency withstand | 3.5 kV AC, 5 min | No breakdown | Routine |
| 3 | DC withstand test | 6.5 kV DC, 15 min | No breakdown | Routine |
| 4 | Insulation resistance | At 500 V DC, 20 °C | ≥ 200 MΩ·km | Routine |
| 5 | Dimensional check | Micrometer | Inner insulation ≥ 0.8 mm; outer sheath ≥ 0.8 mm; OD ≈ 5.1 mm | Routine |
| 6 | UV preconditioning | 1000 h UV exposure | No cracking / embrittlement | Type |
| 7 | Thermal ageing | 168 h at 135 °C | No cracking after bend test | Type |
| 8 | Cold bend test | −40 °C, mandrel 4×OD | No cracks | Type |
| 9 | Heat shock | 15 min at 150 °C | No cracking | Type |
| 10 | Single-cable flame | IEC 60332-1 vertical flame | Self-extinguishing | Type |
| 11 | Halogen acid gas | IEC 60754-1/-2 | ≤ 0.5% HCl equivalent | Type |
| 12 | Smoke density | IEC 61034-2 | Light transmittance ≥ 60% | Type |
| 13 | Ozone resistance | Ozone chamber test | No cracking | Type |
| 14 | Abrasion resistance | Tape abrasion test | Per EN 50618 | Type |
| 15 | Tinned copper check | Strip test on strands | Uniform tin coating | Routine |
| 16 | Marking legibility | Visual + rubbing | H1Z2Z2-K / 1×4.0 / HAR / metre marks | Routine |
Cable Cross Section Structure

| H1Z2Z2-K 1×4.0 mm² — Cross-Section Construction Diagram (Schematic) | |||||
| Harmonised PV cable build-up: tinned copper flexible conductor → inner halogen-free XLPE insulation → outer halogen-free cross-linked polyolefin sheath · 0.6/1.0 kV DC · IEC 60332-1 · finished Ø ≈ 5.1 mm | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Conductor | Flexible stranded tinned copper, Class 5 — 56 × 0.30 mm | — | ≈ 2.5 | Power conductor; R ≤ 4.49 Ω/km at 20 °C |
| 2 | Inner insulation | Halogen-free cross-linked polyethylene (XLPE), Z2 | 0.8 | ≈ 4.1 | Main electrical insulation; halogen-free |
| 3 | Outer sheath | Halogen-free cross-linked polyolefin, Z2, black | 0.8 | ≈ 5.1 (finished) | Weather jacket; UV/ozone resistant; halogen-free |
| 4 | (No armour) | — | — | — | Unarmoured — flexible cable for PV use |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 5.1 | mm | 2.5 + 2×0.8 + 2×0.8 | ||
| Approx. cable mass | ≈ 45 | kg/km | Cu + XLPE + sheath | ||
| Nominal voltage rating | 0.6/1.0 | kV DC | PV array DC | ||
| Max system voltage | 1.8 | kV DC | Open-circuit Voc | ||
| Max continuous conductor temp. | 90 | °C | Standard rated | ||
| Short-circuit temp. (≤5 s) | 250 | °C | XLPE limit | ||
| Min installation temp. | -40 | °C | Cold-bend tested | ||
| Min bending radius | ≥ 4 × OD ≈ 20 | mm | Fixed installation | ||
| DC resistance @ 20 °C | ≤ 4.49 | Ω/km | 4.0 mm² Cu Class 5 | ||
| Insulation resistance | ≥ 200 | MΩ·km | XLPE | ||
| Routine test voltage (AC) | 3.5 kV / 5 min | — | Power-frequency withstand | ||
| Routine test voltage (DC) | 6.5 kV / 15 min | — | DC withstand | ||
| Air ampacity @ 30 °C | ≈ 45 | A | Single core, free air (est.) | ||
| Flame retardancy | IEC 60332-1 | — | Single-cable vertical flame | ||
| Halogen-free | Yes (Z2) | — | IEC 60754 / IEC 61034 | ||
| UV resistance | 1000 h | — | Per EN 50618 | ||
| Schematic — not to exact scale. Finished Ø ≈ 5.1 mm and weight ≈ 45 kg/km from cross-referenced industry samples; conductor/insulation dimensions per EN 50618 and EN 60228; ampacity 45 A is an engineering estimate for single core in free air. H1Z2Z2-K is the harmonised European equivalent of PV1-F — the key difference is the double-layer construction (inner halogen-free XLPE insulation + outer halogen-free cross-linked polyolefin sheath), both rated Z2 (halogen-free). The HAR certification mark confirms compliance with the harmonised European standard. Always use PV4/MC4-type connectors crimped with the dedicated tool. Values marked (est.) require confirmation against the factory test certificate. | |||||
Cable Construction Description
| Construction Description — H1Z2Z2-K 1×4.0 mm² (harmonised double-layer halogen-free) | |||
| Layer-by-layer PV build-up · tinned copper flexible / inner halogen-free XLPE insulation + outer halogen-free cross-linked polyolefin sheath · 0.6/1.0 kV DC · IEC 60332-1 · finished Ø ≈ 5.1 mm | |||
| 1. Product Identity & Ratings | |||
| H1Z2Z2-K 1×4.0 is the harmonised European photovoltaic DC cable rated 0.6/1.0 kV DC (max system voltage 1.8 kV), built and certified to EN 50618 / HD 6036 with the HAR (harmonised) certification mark. Unlike PV1-F (which uses a single-layer insulation that doubles as the weather jacket), H1Z2Z2-K uses a double-layer construction: an inner halogen-free XLPE insulation plus an outer halogen-free cross-linked polyolefin sheath, both rated Z2 (halogen-free). This double-layer design provides enhanced mechanical protection and weather resistance. Finished diameter is about 5.1 mm, mass about 45 kg/km, and it is supplied in 100 m coils (residential) or drums (utility). | |||
| 2. Tinned Copper Flexible Conductor | |||
| The 4.0 mm² conductor is Class 5 flexible stranded tinned copper — 56 individual 0.30 mm tinned wires — giving a conductor diameter of about 2.5 mm and a maximum DC resistance of 4.49 Ω/km at 20 °C. The fine-strand construction gives the cable excellent flexibility for routing on rooftop racking, and the tin plating protects the copper strands against oxidation and atmospheric corrosion over decades of outdoor service. | |||
| 3. Inner Halogen-Free XLPE Insulation | |||
| The conductor is fully enclosed in a 0.8 mm layer of halogen-free cross-linked polyethylene (XLPE). This inner layer provides the primary electrical insulation — it is the layer that withstands the 3.5 kV AC routine test. The Z2 designation means the insulation contains no halogen compounds, so when burned it releases no hydrochloric acid gas. The irradiation process cross-links the polymer chains, giving XLPE a 90 °C continuous conductor temperature rating (short-circuit up to 250 °C for ≤ 5 s). | |||
| 4. Outer Halogen-Free Cross-Linked Sheath | |||
| Over the inner insulation is a 0.8 mm layer of halogen-free cross-linked polyolefin — the outer weather jacket. This outer sheath provides mechanical protection against abrasion, UV radiation, ozone, and weathering. It is the layer that faces the outside environment. The black carbon-loaded sheath is UV-resistant (1000 h UV preconditioning). The double-layer design (insulation + sheath) is the key structural difference from PV1-F, which uses a single-layer insulation that doubles as the jacket. | |||
| 5. Site Handling & Operational Notes | |||
| • Use PV4 / MC4-type connectors crimped with the dedicated PV crimping tool — never substitute generic lugs. • Observe the 4 × OD minimum bend radius (≈ 20 mm); if flexed repeatedly, use 6 × OD. • Service range −40 to +90 °C; conductor up to 90 °C continuous. • Routine test 3.5 kV AC / 5 min. • UV preconditioning: 1000 h UV exposure per EN 50618. • Halogen-free: IEC 60754 acid gas ≤ 0.5% HCl; IEC 61034 smoke transmittance ≥ 60%. • At ≈ 4.5 kg per 100 m, the cable is light and supplied in 100 m coils — ideal for residential European rooftop PV. • The HAR mark confirms harmonised European compliance — required for projects that specify harmonised cables. |
8. Factory Advantages.
- Tinned copper — anti-corrosion for outdoor moisture and oxidation.
- Irradiated XLPO — UV/ozone/heat stable for long outdoor life.
- Wide temperature range — -40~+90 °C from cold deserts to hot roofs.
- Flexible fine stranding — dresses quickly on racks and rooftops.
- PV polarity colors — red/black makes DC polarity clear.
- Routine electrical QA — consistent PV-grade output.
- Length-on-coil — cut to string length with less waste.
- Lightweight — ≈55 kg/km, easy roof handling.
- Certified support pack — test record and PV data for solar tenders.
9. Packaging, Storage & Logistics. Cut to string/run length on coils with sealed ends; store dry indoor, shaded before installation.
10. Procurement Specification. State "H1Z2Z2-K 1×4.0", length, and red/black polarity requirement; request the routine DC test record and type (UV/aging) evidence. Est. values confirmed against the factory type certificate.
11. Cable Industry FAQ.
- Q1: What does H1Z2Z2-K mean? A harmonized flexible (K) PV cable: outdoor-rated (1), two layers of cross-linked polyolefin (Z2) for insulation and sheath, for DC photovoltaic circuits.
- Q2: Why tinned copper? Tinning resists moisture and outdoor corrosion, important on open arrays.
- Q3: What voltage? 1.5 kV DC for the PV string/combiner/inverter DC side.
- Q4: Is it fire-rated (950 °C)? No — it is a weather-resistant PV cable; choose fire-rated cable (e.g. BTTRZ) for life-safety circuits.
- Q5: DC resistance? ≤5.09 Ω/km at 20 °C for the flexible 4.0 mm² tinned core.
- Q6: Current rating? ≈35 A (est.) free air; derate by grouping and enclosure.
- Q7: Why red and black? Red = positive (+), black = negative (−), so DC polarity stays correct on the array.
- Q8: UV resistant? Yes — irradiated XLPO is rated for long-term outdoor sun and ozone.
- Q9: Temperature range? -40~+90 °C, from cold-climate to hot-roof installs.
- Q10: Packing? Light cable on coils with sealed ends.
- Q11: What proof ships? Routine DC test record plus UV/aging type evidence; est. values confirmed against it.