logo
Anhui Tongdu International Trade Co., Ltd.
온라인 서비스

온라인 서비스

담당자
+86 19056002718
위챗 QR 코드
따라와
No Products Found Matching Your Search Criteria:

"0 5mm to 2 5mm flat electrical sheathed wires"

Please try a different search term or browse our product categories.

Recommend Other Products
품질 6.0mm2 태양광 케이블 내후성 XLPO UV 저항성 태양광 케이블 공장

6.0mm2 태양광 케이블 내후성 XLPO UV 저항성 태양광 케이블

UV Resistant Solar Cable H1Z2Z2-K 6.0mm² TUV 1500V DC Weatherproof PV Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z ...

품질 PV 케이블 PV1-F 4.0mm² TUV UV 내성 방수 1500V DC 태양광 공장

PV 케이블 PV1-F 4.0mm² TUV UV 내성 방수 1500V DC 태양광

PV Cable PV1-F 4.0mm² TUV UV Resistant Weatherproof 1500V DC Photovoltaic Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...

품질 ? 공장

?

Super Heavy MV Cable YJV22 3x300mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...

품질 메가 산업 메인 케이블 YJV22 3x120mm2 8.7/15kV 장갑 MV XLPE 공장

메가 산업 메인 케이블 YJV22 3x120mm2 8.7/15kV 장갑 MV XLPE

Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; U...

품질 고 용량 MV 케이블 YJV22 3x95mm2 8.7/15kV 장갑 XLPE 전력 케이블 공장

고 용량 MV 케이블 YJV22 3x95mm2 8.7/15kV 장갑 XLPE 전력 케이블

High Capacity MV Cable YJV22 3x95mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...

품질 YJV22 8.7/10kV 장갑 XLPE 3심 70mm² 주 배전 케이블 공장

YJV22 8.7/10kV 장갑 XLPE 3심 70mm² 주 배전 케이블

Primary Distribution Cable 3 Core 70mm² YJV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; ...

품질 3 코어 장갑 MV 케이블 YJV22 3x50mm2 8.7/10kV 8.7/15kV XLPE 전력 케이블 공장

3 코어 장갑 MV 케이블 YJV22 3x50mm2 8.7/10kV 8.7/15kV XLPE 전력 케이블

3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...

품질 4+1 코어 내화 케이블 120mm2+1x95mm2 BTTRZ 내화 변전소 케이블 공장

4+1 코어 내화 케이블 120mm2+1x95mm2 BTTRZ 내화 변전소 케이블

Fire Substation Cable 4+1 Core 120mm²+1x95mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6...