"0 5mm to 2 5mm flat electrical sheathed wires"
Please try a different search term or browse our product categories.
6.0mm2 태양광 케이블 내후성 XLPO UV 저항성 태양광 케이블
UV Resistant Solar Cable H1Z2Z2-K 6.0mm² TUV 1500V DC Weatherproof PV Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z ...
PV 케이블 PV1-F 4.0mm² TUV UV 내성 방수 1500V DC 태양광
PV Cable PV1-F 4.0mm² TUV UV Resistant Weatherproof 1500V DC Photovoltaic Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
?
Super Heavy MV Cable YJV22 3x300mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
메가 산업 메인 케이블 YJV22 3x120mm2 8.7/15kV 장갑 MV XLPE
Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; U...
고 용량 MV 케이블 YJV22 3x95mm2 8.7/15kV 장갑 XLPE 전력 케이블
High Capacity MV Cable YJV22 3x95mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
YJV22 8.7/10kV 장갑 XLPE 3심 70mm² 주 배전 케이블
Primary Distribution Cable 3 Core 70mm² YJV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; ...
3 코어 장갑 MV 케이블 YJV22 3x50mm2 8.7/10kV 8.7/15kV XLPE 전력 케이블
3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
4+1 코어 내화 케이블 120mm2+1x95mm2 BTTRZ 내화 변전소 케이블
Fire Substation Cable 4+1 Core 120mm²+1x95mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6...