"0 5mm to 2 5mm flat electrical sheathed wires"
Please try a different search term or browse our product categories.
2.5mm2 ठोस तांबा कंडक्टर जमीन ठोस पृथ्वी थन लौ retardant
Yellow Green BV 2.5mm² Ground Earth Wire PVC Insulated Copper Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or stranded)...
सिंगल कोर फोटोवोल्टिक सोलर केबल 6.0mm2 TUV Xlpe Cu केबल
1500V DC Solar Wire PV1-F 6.0mm² TUV XLPE Copper Photovoltaic Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, halogen...
आईईसी 62930 सौर तार टिनयुक्त तांबा 0.095 किग्रा/एम सौर पैनलों के लिए पीवी तार
PV Cable PV1-F 6.0mm² TUV 1500V DC Low Smoke Halogen Free Solar Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, ...
XLPE एल्यूमीनियम पावर केबल YJLV22 3x50mm2 8.7/15kV बख्तरबंद 3 कोर एमवी
XLPE Aluminum Power Cable YJLV22 3x50mm² 8.7/15kV Armored 3 Core MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
भारी गेज एमवी केबल YJV22 3x150mm² 8.7/15kV आर्मर्ड XLPE पावर केबल
Heavy Gauge MV Cable YJV22 3x150mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
प्राथमिक वितरण केबल 3 कोर 70mm² YJV22 8.7/10kV आर्मर्ड XLPE
Primary Distribution Cable 3 Core 70mm² YJV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; ...
3 कोर बख्तरबंद एमवी केबल YJV22 3x50mm2 8.7/10kV 8.7/15kV XLPE पावर केबल
3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
4x70mm2+1x50mm2 फायर रेसिस्टेंट केबल 1KV 1.2KV Bare Copper Mineral Insulated Cable
Heavy Duty Fire Cable BTTRZ 4x70mm²+1x50mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...