"750v teflon coated copper wire"
Please try a different search term or browse our product categories.
1.0mm2 軟銅導体 焼きなまし 18 AWG 無被覆銅線
1.0mm2 Solid Copper Conductor Annealed 18 Awg Bare Copper Wire BV 1.0 mm² / 18 AWG — Technical Specification Category Parameter Value / Description Product Identity Model Number BV (equivalent to 60227 IEC 01 / IEC 05) Product Name Copper Conductor PVC Insulated Single-Core Building Wire Standards ...
DCソーラーワイヤ 6.0mm2 PV1-F TUV UV耐性光伏ケーブル PVストリング メインケーブル
DC Solar Wire 6.0mm² PV1-F TUV UV Resistant Photovoltaic Cable PV String Main Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper ...
PV1-F 6.0mm2 TUV 1500V DC 太陽電池ケーブル UV耐性 防天光線
PV1-F 6.0mm² TUV 1500V DC Solar Cable UV Resistant Weatherproof PV Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
DCソーラーワイヤー PV1-F 4.0mm² TUV 1500V 銅 XLPE photovoltaikケーブル
DC Solar Wire PV1-F 4.0mm² TUV 1500V Copper XLPE Photovoltaic Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
3*70mm2 中高圧電力ケーブル 8.5KV 15Kv 地中配電用装甲
ZC-YJV22 8.5/15Kv Armored Medium High Voltage Power Cable for Underground Distribution ZC-YJV22 8.5/15kV 3×70 mm² Medium-Voltage Armoured Power Cable Model decoding: ZC = Class C flame retardant (GB/T 19666) · YJ = XLPE insulation · V = PVC outer sheath · 22 = double steel-tape armour + PVC ...
3コア armored MVケーブル YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPEパワーケーブル
3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
重ゲージMVケーブルYJV22 3x150mm² 8.7/15kV アーマードXLPEパワーケーブル
Heavy Gauge MV Cable YJV22 3x150mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
超重型MVケーブル YJV22 3x185mm2 8.7/15kV 装甲型XLPE電源ケーブル
Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...