"yes solar power cable"
- 35 Items Found
White Copper Building Wire PVC Insulated Single Core Household Electrical Cable
BV 2.5mm2 White PVC Insulated Single Core Copper Building Wire 450/750V Household Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction : Plain ...
Aluminum Concentric Neutral Mv Cable 3x95mm2 3 Core Aluminium Armoured Cable
Main Distribution Aluminum Cable YJLV22 3x95mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
High Capacity Mv Armoured Cable 150mm2 XLPE 3 Core Aluminum Cable
High Capacity Aluminum Cable 3 Core 150mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
3x240mm2 Flexible Medium Voltage Cable 8.7kV 15kV 3 Core Cable
XLPE Medium Voltage Aluminum Cable YJLV22 3x240mm2 8.7/15kV Armored 3 Core Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 ...
TUV 1kV Photovoltaic Solar Cable H1Z2Z2-K 4mm2 Pv Cable
1500V DC Solar Wire H1Z2Z2-K 4.0mm² TUV XLPE Photovoltaic Cable Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen-free ...
4.0mm2 TUV Photovoltaic Cable 1500V Non Corrosive Photovoltaic Wire
H1Z2Z2-K 4.0mm² TUV Certified Solar Cable 1500V DC Photovoltaic Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen...
PV1-F 4.0mm² TUV Certified Solar Cable 1500V DC UV Resistant Photovoltaic Wire
PV1-F 4.0mm² TUV Certified Solar Cable 1500V DC UV Resistant Photovoltaic Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper ...
PV1-F 6.0mm² TUV 1500V DC Solar Cable UV Resistant Weatherproof PV Wire
PV1-F 6.0mm² TUV 1500V DC Solar Cable UV Resistant Weatherproof PV Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...