"flat sheathed wires flat electrical sheathed wires"
- 42 Items Found
Heavy Duty 4 Core Control Flex Cable RVV 4x4.0mm2 PVC Stranded Copper Cable
Heavy Duty 4 Core Cable RVV 4x4.0mm² PVC Stranded Copper Flexible Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 4×4.0 mm² Four flexible cores, each 4.0 mm² copper conductor ...
4 Core Industrial Power Cable 10mm2 RVV PVC Flexible Stranded Copper
Industrial Power Cable 4 Core 10mm² RVV PVC Flexible Stranded Copper 300/500V Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 4×10 mm² Four flexible cores, each 10 mm² copper ...
4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV
4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×16 mm² + 1×10 mm² Four cores of 16 mm² (3 phase + 1 neutral) + one ...
0.6/1kV XLPE Copper Cable ZR-YJV 4x25mm²+1x16mm² Flame Retardant for Power Supply
0.6/1kV XLPE Copper Cable ZR-YJV 4x25mm²+1x16mm² Flame Retardant for Power Supply Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×25 mm² + 1×16 mm² Four cores of 25 mm² (3 phase + 1 neutral) + one ...
Copper Core 5 Core Shielded Cable 4x50mm2+1x25mm2 XLPE Flame Retardant 0.6/1kV
Copper Core 4+1 Cable ZR-YJV 4x50mm²+1x25mm² XLPE Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×50 mm² + 1×25 mm² Four cores of 50 mm² (3 phase + 1 neutral) + one earth ...
High Rise Building Main Cable ZR-YJV 4x95mm²+1x50mm² XLPE Copper Flame Retardant
High Rise Building Main Cable ZR-YJV 4x95mm²+1x50mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×95 mm² + 1×50 mm² Four cores of 95 mm² (3 phase + 1 neutral) + one ...
Heavy Duty 4+1 Core Cable ZR-YJV 4x120mm²+1x70mm² XLPE Copper Flame Retardant
Heavy Duty 4+1 Core Cable ZR-YJV 4x120mm²+1x70mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×120 mm² + 1×70 mm² Four cores of 120 mm² (3 phase + 1 neutral) + one ...
Shopping Mall Main Power Cable ZR-YJV 4x150mm²+1x70mm² XLPE Copper Flame Retardant
Shopping Mall Main Power Cable ZR-YJV 4x150mm²+1x70mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×150 mm² + 1×70 mm² Four cores of 150 mm² (3 phase + 1 neutral) + ...
Flame Retardant XLPE Cable 4+1 Core 4×185mm²+1*95mm² ZR-YJV Copper 0.6/1kV
Flame Retardant XLPE Cable 4+1 Core 4×185mm²+1*95mm² ZR-YJV Copper 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×185 mm² + 1×95 mm² Four cores of 185 mm² (3 phase + 1 neutral) + one earth ...