"4x2 5mm2 stranded copper cable"
Please try a different search term or browse our product categories.
4.0mm2 Katı Bakır iletken 450V 750V Tek iplik bakır tel
BV 4.0mm² Solid Copper PVC Insulated Building Wire 450/750V Easy Pull Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 4.0 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor ...
IEC 62930 Güneş Kablosu Kalaylı Bakır 0.095kg/M Güneş Panelleri İçin Pv Kablo
PV Cable PV1-F 6.0mm² TUV 1500V DC Low Smoke Halogen Free Solar Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, ...
DC Solar Kablosu 6.0mm² PV1-F TUV UV Dayanımlı Fotovoltaik Kablo PV String Ana Kablosu
DC Solar Wire 6.0mm² PV1-F TUV UV Resistant Photovoltaic Cable PV String Main Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper ...
Yüksek Kapasiteli MV Zırhlı Kablo 150mm2 XLPE 3 Damarlı Alüminyum Kablo
High Capacity Aluminum Cable 3 Core 150mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
Dev Güç Kablosu YJV22 3x400mm² 8.7/15kV Zırhlı XLPE Güç Kablosu
Giant MV Cable YJV22 3x400mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; Uₘ = ...
Ana Dağıtım Kablosu 3 Damarlı 70mm² YJV22 8.7/10kV Zırhlı XLPE
Primary Distribution Cable 3 Core 70mm² YJV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; ...
BTLY Yangına Dayanıklı Kablo 4x35mm2 + 1x16mm2 Acil Durumlar İçin Alüminyum Kılıflı Kablo
NG-A BTLY 4x35+1x16mm2 Mineral Insulated Fire Resistant Aluminum Sheath Cable for Emergency Cable Designation & Meaning Code Meaning NG-A New Generation A-class fire-resistant (Chinese designation) (BTLY) Building wire, Thin copper conductor, Lightweight Y— alternative naming convention indicating: ...
4x185mm2 + 1x150mm2 Yangına dayanıklı kablo 0.6KV 1KV Mineral yalıtımlı bakır kablo
Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...