Product Details
Place of Origin: China
Brand Name: Qifan
Certification: ISO, CCC, CE, RoHS, TUV
Model Number: YJV32 YJLV32
Payment & Shipping Terms
Minimum Order Quantity: 100m
Price: usd3-8/meter
Packaging Details: wooden drumsPackaging Details Inner Packing: Wooden reel, Plastic reel, and Paper Reel Outer Packing: Carton box, Pull out box, Pallet available Other packing available according to clients' request
Delivery Time: 30-45days
Payment Terms: D/A, D/P, L/C, T/T, Western Union, MoneyGram
Supply Ability: 50000K Meter/ per Month
Model NO.: |
YJV32 YJLV32 |
Wire Core Material: |
Pure Annealed Soft Copper |
Model: |
Yjlv32 |
Brand: |
Qifan |
Free Sample: |
Yes |
Staff: |
3048 |
Standard: |
IEC BS En VDE |
Engineer No.: |
206 |
Plant No.: |
3 Plant With 12 Workshop |
Transport Package: |
Drum |
Specification: |
25-1600mm2 |
Trademark: |
QIFAN |
Origin: |
China |
HS Code: |
8544601290 |
Supply Ability: |
50000km/Month |
Application: |
Construction, Overhead, Underground, Industrial, Power Station |
Voltage: |
Medium Voltage Cable |
Current: |
DC & AC |
Insulation Material: |
XLPE |
Sheath Material: |
PVC |
Material Shape: |
Round Wire |
Samples: |
US$ 0/Meter 1 Meter(Min.Order) | Request Sample |
Model NO.: |
YJV32 YJLV32 |
Wire Core Material: |
Pure Annealed Soft Copper |
Model: |
Yjlv32 |
Brand: |
Qifan |
Free Sample: |
Yes |
Staff: |
3048 |
Standard: |
IEC BS En VDE |
Engineer No.: |
206 |
Plant No.: |
3 Plant With 12 Workshop |
Transport Package: |
Drum |
Specification: |
25-1600mm2 |
Trademark: |
QIFAN |
Origin: |
China |
HS Code: |
8544601290 |
Supply Ability: |
50000km/Month |
Application: |
Construction, Overhead, Underground, Industrial, Power Station |
Voltage: |
Medium Voltage Cable |
Current: |
DC & AC |
Insulation Material: |
XLPE |
Sheath Material: |
PVC |
Material Shape: |
Round Wire |
Samples: |
US$ 0/Meter 1 Meter(Min.Order) | Request Sample |
Item | Category A ,B | 3.6/6kV | 6/10kV | 8.7/15kV | 12/20kV | 18/30kV | 21/35kV |
Category A ,B | 6/6kV | 8.7/10kV | 12/15kV | 18/20kV | - | 26/35kV | |
Single core | mm2 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 |
Three core | mm2 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 |
Type | Designation | Applications | |
YJV | Copper conductor,XLPE insulated,PVC sheathed power cable | For laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct. | |
YJLV | Aluminum conductor,XLPE insulated,PVC sheathed power cable | ||
YJY | Copper conductor, XLPE insulated,PE sheathed power cable | ||
YJLY | Aluminum conductor, XLPE insulated,PE sheathed power cable | ||
YJV22 | Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable | For laying indoors,in tunnel in cable trench,or direct in ground,able to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct. | |
YJLV22 | Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable | ||
YJV23 | Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cable | ||
YJLV23 | Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cable | ||
YJV32 | Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable | For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force. | |
YJLV32 | Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable | ||
YJV33 | Copper conductor,XLPE insulated,steel wire armoured,PE sheathed power cable | ||
YJLV33 | Aluminum conductor,XLPE insulated,steel wire armoured,PE sheathed power cable |
SWA Armoured 3-core cable with XLPE insualtion. Rated voltage 3.6/6(7.2)kV 3.8/6.6(7.2) KV Cable Data
CU/XLPE/PVC/SWA/PVC
Conductor |
Insulation thickness (mm) |
Copper tape screen (approximate) (mm) |
Bedding thickness (mm) |
Armored wire outer diameter (mm) |
Sheath thickness (mm) |
Outer diameter (approximate) (mm) |
Copper core cable weight (kg/km) |
Aluminum core cable weight (kg/km) |
||
Cross sectional area (mm2) |
Structure |
Outer diameter (mm) |
||||||||
25 |
Compact round |
6.0 |
2.5 |
0.1 |
1.2 |
2.0 |
2.3 |
42.1 |
3317 |
2845 |
35 |
Compact round |
7.2 |
2.5 |
0.1 |
1.3 |
2.5 |
2.5 |
46.7 |
4312 |
3651 |
50 |
Compact round |
8.4 |
2.5 |
0.1 |
1.3 |
2.5 |
2.5 |
49.3 |
4972 |
4028 |
70 |
Compact round |
10.0 |
2.5 |
0.1 |
1.4 |
2.5 |
2.7 |
53.3 |
5968 |
4646 |
95 |
Compact round |
11.7 |
2.5 |
0.1 |
1.4 |
2.5 |
2.8 |
57.2 |
7033 |
5239 |
120 |
Compact round |
13.1 |
2.5 |
0.1 |
1.5 |
2.5 |
2.9 |
60.6 |
8072 |
5807 |
150 |
Compact round |
14.6 |
2.5 |
0.1 |
1.6 |
2.5 |
3.0 |
64.2 |
9288 |
6456 |
185 |
Compact round |
16.3 |
2.5 |
0.1 |
1.6 |
2.5 |
3.1 |
68.1 |
10737 |
7245 |
240 |
Compact round |
18.5 |
2.6 |
0.1 |
1.7 |
2.5 |
3.3 |
73.9 |
12869 |
8339 |
300 |
Compact round |
20.7 |
2.8 |
0.1 |
1.8 |
3.15 |
3.5 |
81.8 |
16183 |
10520 |
400 |
Compact round |
23.8 |
3.0 |
0.1 |
2.0 |
3.15 |
3.8 |
90.4 |
20070 |
12519 |
500 |
Compact round |
26.6 |
3.2 |
0.1 |
2.1 |
3.15 |
4.1 |
99.3 |
24131 |
14692 |
Conductor |
Insulation thickness (mm) |
Copper tape screen (approximate) (mm) |
Bedding thickness (mm) |
Armored wire outer diameter (mm) |
Sheath thickness (mm) |
Outer diameter (approximate) (mm) |
Copper core cable weight (kg/km) |
Aluminum core cable weight (kg/km) |
||
Cross sectional area (mm2) |
Structure |
Outer diameter (mm) |
||||||||
25 |
Compact round |
6.0 |
3.4 |
0.1 |
1.3 |
2.5 |
2.5 |
48.0 |
4175 |
3703 |
35 |
Compact round |
7.2 |
3.4 |
0.1 |
1.3 |
2.5 |
2.6 |
50.8 |
4733 |
4072 |
50 |
Compact round |
8.4 |
3.4 |
0.1 |
1.4 |
2.5 |
2.7 |
53.8 |
5491 |
4547 |
70 |
Compact round |
10.0 |
3.4 |
0.1 |
1.5 |
2.5 |
2.8 |
57.6 |
6446 |
5124 |
95 |
Compact round |
11.7 |
3.4 |
0.1 |
1.5 |
2.5 |
2.9 |
61.5 |
7530 |
5737 |
120 |
Compact round |
13.1 |
3.4 |
0.1 |
1.6 |
2.5 |
3.0 |
64.9 |
8628 |
6363 |
150 |
Compact round |
14.6 |
3.4 |
0.1 |
1.6 |
2.5 |
3.1 |
68.3 |
9794 |
6963 |
185 |
Compact round |
16.3 |
3.4 |
0.1 |
1.7 |
2.5 |
3.3 |
72.6 |
11326 |
7834 |
240 |
Compact round |
18.5 |
3.4 |
0.1 |
1.8 |
3.15 |
3.5 |
79.2 |
14268 |
9737 |
300 |
Compact round |
20.7 |
3.4 |
0.1 |
1.9 |
3.15 |
3.6 |
84.8 |
16641 |
10978 |
400 |
Compact round |
23.8 |
3.4 |
0.1 |
2.0 |
3.15 |
3.9 |
92.3 |
20362 |
12811 |
500 |
Compact round |
26.6 |
3.4 |
0.1 |
2.1 |
3.15 |
4.1 |
99.3 |
24203 |
14764 |
SWA Armoured 3-core cable with XLPE insualtion. Rated voltage 12/20(24) KV 12.7/22(24)kV
Cable Data
Conductor |
Insulation thickness (mm) |
Copper tape screen (approximate) (mm) |
Bedding thickness (mm) |
Armored wire diameter (mm) |
Sheath thickness (mm) |
Outer diameter (approximate) (mm) |
Copper core cable weight (kg/km) |
Aluminum core cable weight (kg/km) |
||
Cross sectional area (mm2) |
Structure |
Outer diameter (mm) |
||||||||
35 |
Compact round |
7.2 |
5.5 |
0.1 |
1.5 |
2.5 |
2.9 |
60.8 |
5934 |
5273 |
50 |
Compact round |
8.4 |
5.5 |
0.1 |
1.6 |
2.5 |
3.0 |
63.8 |
6706 |
5763 |
70 |
Compact round |
10.0 |
5.5 |
0.1 |
1.6 |
2.5 |
3.1 |
67.5 |
7699 |
6378 |
95 |
Compact round |
11.7 |
5.5 |
0.1 |
1.7 |
2.5 |
3.3 |
71.7 |
8932 |
7139 |
120 |
Compact round |
13.1 |
5.5 |
0.1 |
1.8 |
3.15 |
3.4 |
76.4 |
10907 |
8641 |
150 |
Compact round |
14.6 |
5.5 |
0.1 |
1.8 |
3.15 |
3.5 |
79.9 |
12187 |
9355 |
185 |
Compact round |
16.3 |
5.5 |
0.1 |
1.9 |
3.15 |
3.6 |
83.9 |
13742 |
10250 |
240 |
Compact round |
18.5 |
5.5 |
0.1 |
2.0 |
3.15 |
3.8 |
89.3 |
16001 |
11471 |
300 |
Compact round |
20.7 |
5.5 |
0.1 |
2.1 |
3.15 |
4.0 |
95.0 |
18538 |
12875 |
400 |
Compact round |
23.8 |
5.5 |
0.1 |
2.2 |
3.15 |
4.2 |
102.3 |
22314 |
14762 |
500 |
Compact round |
26.6 |
5.5 |
0.1 |
2.3 |
3.15 |
4.4 |
110.2 |
26392 |
16953 |
Conductor |
Insulation thickness (mm) |
Copper tape screen (approximate) (mm) |
Bedding thickness (mm) |
Armored wire diameter (mm) |
Sheath thickness (mm) |
Outer diameter (approximate) (mm) |
Copper core cable weight (kg/km) |
Aluminum core cable weight (kg/km) |
||
Cross sectional area (mm2) |
Structure |
Outer diameter (mm) |
||||||||
50 |
Compact round |
8.4 |
8.0 |
0.1 |
1.8 |
3.15 |
3.5 |
77.3 |
9333 |
8390 |
70 |
Compact round |
10.0 |
8.0 |
0.1 |
1.8 |
3.15 |
3.6 |
80.9 |
10396 |
9075 |
95 |
Compact round |
11.7 |
8.0 |
0.1 |
1.9 |
3.15 |
3.7 |
85.0 |
11723 |
9930 |
120 |
Compact round |
13.1 |
8.0 |
0.1 |
2.0 |
3.15 |
3.8 |
88.4 |
12986 |
10720 |
150 |
Compact round |
14.6 |
8.0 |
0.1 |
2.0 |
3.15 |
3.9 |
91.8 |
14220 |
11388 |
185 |
Compact round |
16.3 |
8.0 |
0.1 |
2.1 |
3.15 |
4.0 |
95.9 |
15887 |
12395 |
240 |
Compact round |
18.5 |
8.0 |
0.1 |
2.2 |
3.15 |
4.2 |
101.2 |
18144 |
13613 |
300 |
Compact round |
20.7 |
8.0 |
0.1 |
2.3 |
3.15 |
4.4 |
107.0 |
20761 |
15097 |
400 |
Compact round |
23.8 |
8.0 |
0.1 |
2.4 |
3.15 |
4.6 |
114.3 |
24824 |
17273 |
500 |
Compact round |
26.6 |
8.0 |
0.1 |
2.5 |
3.15 |
4.8 |
122.2 |
29019 |
19580 |
IEC 60502: This is an international standard that covers power cables with rated voltages up to 30kV. It specifies the requirements for various cable types and their testing procedures.
BS 7835: This is a British Standard that sets requirements for medium voltage cables used in electricity supply systems. It covers aspects such as cable construction, materials, and testing.
BS 6622: Another British Standard, BS 6622 specifically focuses on medium voltage power cables for use in distribution networks. It provides guidelines for cable design, construction, and testing.
VDE: This refers to the German Association for Electrical, Electronic & Information Technologies. VDE provides standards and regulations related to electrical engineering and technology.
Cable Types:
N2xsey: This is a type of power cable that conforms to the European standard HD 620. It features copper conductors, XLPE (cross-linked polyethylene) insulation, and a PVC sheath. It is suitable for outdoor energy distribution.
N2xsy: Similar to N2xsey, N2xsy is another type of power cable that meets the European standard HD 620. It also has copper conductors, XLPE insulation, and a PVC sheath. It is designed for outdoor use.
Yjv32: Yjv32 is a power cable commonly used in China. It has copper conductors, XLPE insulation, and is armored with steel tape. It can be used for outdoor energy transmission.
Voltage Ratings:
The cable you mentioned is available in different voltage ratings, including 11kV, 20kV, and 33kV. These ratings indicate the maximum voltage at which the cable can safely operate