Fangyu(shanghai)Automation Technology Co.,Ltd
products
products
Home > products > Medium Voltage Power Cable > Medium Voltage Power Cable N2xsy N2xsey Yjv32 Copper Conductor XLPE Insulated Cable

Medium Voltage Power Cable N2xsy N2xsey Yjv32 Copper Conductor XLPE Insulated Cable

Product Details

Place of Origin: China

Brand Name: Qifan

Certification: ISO, CCC, CE, RoHS, TUV

Payment & Shipping Terms

Minimum Order Quantity: 100m

Price: usd3-8/meter

Packaging Details: wooden drumsPackaging Details Inner Packing: Wooden reel, Plastic reel, and Paper Reel Outer Packing: Carton box, Pull out box, Pallet available Other packing available according to clients' request

Delivery Time: 30-45days

Payment Terms: D/A, D/P, L/C, T/T, Western Union, MoneyGram

Supply Ability: 50000K Meter/ per Month

Get Best Price
Highlight:

11kv Medium Voltage Power Cable

,

20kv Medium Voltage Power Cable

,

30kv medium voltage cable

Model NO.:
YJV32 YJV22
Wire Core Material:
Annealed Soft Copper
Model:
Yjv32 Yjv22 Yjsv
Brand:
Qifan
Free Sample:
Yes
Staff:
3048
Standard:
IEC VDE BS As Icea
Engineer No.:
206
Plant No.:
3 Plant With 12 Workshop
Transport Package:
Drum
Specification:
25-1600mm2
Trademark:
QIFAN
Origin:
China
HS Code:
8544601200
Supply Ability:
50000km/Month
Application:
Construction, Overhead, Underground, Industrial, Power Station
Voltage:
Medium Voltage Cable
Current:
DC & AC
Insulation Material:
XLPE
Sheath Material:
PVC
Material Shape:
Round Wire
Samples:
US$ 0/Meter 1 Meter(Min.Order) | Request Sample
Model NO.:
YJV32 YJV22
Wire Core Material:
Annealed Soft Copper
Model:
Yjv32 Yjv22 Yjsv
Brand:
Qifan
Free Sample:
Yes
Staff:
3048
Standard:
IEC VDE BS As Icea
Engineer No.:
206
Plant No.:
3 Plant With 12 Workshop
Transport Package:
Drum
Specification:
25-1600mm2
Trademark:
QIFAN
Origin:
China
HS Code:
8544601200
Supply Ability:
50000km/Month
Application:
Construction, Overhead, Underground, Industrial, Power Station
Voltage:
Medium Voltage Cable
Current:
DC & AC
Insulation Material:
XLPE
Sheath Material:
PVC
Material Shape:
Round Wire
Samples:
US$ 0/Meter 1 Meter(Min.Order) | Request Sample
Medium Voltage Power Cable N2xsy N2xsey Yjv32 Copper Conductor XLPE Insulated Cable

Product Description

Medium Voltage   Copper Aluminum Conductor XLPE Insulated Armored Power Electric Cable 

Product Standard
This product is manufactured according to GB/T12706.2, equivalent to IEC60502.2. Or BS, DIN, ICEA standard as customer request.  
 Application
The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv.
3 Operating characteristics
- Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv.
- Max.admissible operating temperature of the conductor:90ºC.
- Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration)
- The ambient temperature under installation should not below 00C.
- The bending radius of a single-core cable should not less than 20 times of the cable diameter. 
The bending radius of a multi-core cable should not less than 15 times of the cable diameter. 

Table of the voltage, cores and cross-section
Item Category    A ,B 3.6/6kV 6/10kV 8.7/15kV 12/20kV 18/30kV 21/35kV
Category    A ,B 6/6kV 8.7/10kV 12/15kV 18/20kV - 26/35kV
Single core mm2 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
Three core mm2 25-400 25-400 35-400 50-400 50-400 50-400
The cable with Category A rated voltage is used in the situation requiring not over 1 min. of grounding fault lasting time. For the cable with Category B rated voltage, the grounding fault lasting time normally is not over 1 hour, max. lasting time is not over 8 hours, annual ground fault lasting time altogether should not be over 125 hours, Category C includes all the system expect Category A and B.

Type and Name
Type Designation Applications
YJV Copper conductor,XLPE insulated,PVC sheathed power cable For laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.
YJLV Aluminum conductor,XLPE insulated,PVC sheathed power cable
YJY Copper conductor, XLPE insulated,PE sheathed power cable
YJLY Aluminum conductor, XLPE insulated,PE sheathed power cable
YJV22 Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable For laying indoors,in tunnel in cable trench,or direct in ground,able to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.
YJLV22 Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable
YJV23 Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJLV23 Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJV32 Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force.
YJLV32 Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable
YJV33 Copper conductor,XLPE insulated,steel wire armoured,PE sheathed power cable
YJLV33 Aluminum conductor,XLPE insulated,steel wire armoured,PE sheathed power cable
 Armoured 3-core cable with XLPE insualtion. Rated voltage 6/10 KV 6.35/11KV

Cable Data

Conductor

 

Insulation thickness (mm)

 

Copper tape screen (approximate) (mm)

 

PVC

bedding thickness (mm)

 

Armored wire outer diameter (mm)

 

Sheath thickness (mm)

 

Outer diameter (approximate) (mm)

 

Copper core cable weight (kg/km)

 

Aluminum core cable weight (kg/km)

Cross sectional area (mm2)

 

Structure

Outer diameter (mm)

25

Compact round

6.0

3.4

0.1

1.3

2.5

2.5

48.0

4175

3703

35

Compact round

7.2

3.4

0.1

1.3

2.5

2.6

50.8

4733

4072

50

Compact round

8.4

3.4

0.1

1.4

2.5

2.7

53.8

5491

4547

70

Compact round

10.0

3.4

0.1

1.5

2.5

2.8

57.6

6446

5124

95

Compact round

11.7

3.4

0.1

1.5

2.5

2.9

61.5

7530

5737

120

Compact round

13.1

3.4

0.1

1.6

2.5

3.0

64.9

8628

6363

150

Compact round

14.6

3.4

0.1

1.6

2.5

3.1

68.3

9794

6963

185

Compact round

16.3

3.4

0.1

1.7

2.5

3.3

72.6

11326

7834

240

Compact round

18.5

3.4

0.1

1.8

3.15

3.5

79.2

14268

9737

300

Compact round

20.7

3.4

0.1

1.9

3.15

3.6

84.8

16641

10978

400

Compact round

23.8

3.4

0.1

2.0

3.15

3.9

92.3

20362

12811

500

Compact round

26.6

3.4

0.1

2.1

3.15

4.1

99.3

24203

14764

Armoured 3-core cable with XLPE insualtion. Rated voltage 8.7/10kV 8.7/15 KV

Cable Data

Conductor

 

Insulation thickness (mm)

 

Copper tape screen (approximate) (mm)

 

PVC

bedding thickness (mm)

 

Armored wire outer diameter (mm)

 

Sheath thickness (mm)

 

Outer diameter (approximate) (mm)

 

Copper core cable weight (kg/km)

 

Aluminum core cable weight (kg/km)

Cross sectional area (mm2)

 

Structure

Outer diameter (mm)

25

Compact round

6.0

4.5

0.1

1.4

2.5

2.7

53.3

4803

4331

35

Compact round

7.2

4.5

0.1

1.4

2.5

2.8

56.1

5379

4719

50

Compact round

8.4

4.5

0.1

1.5

2.5

2.9

59.1

6091

5147

70

Compact round

10.0

4.5

0.1

1.5

2.5

3.0

62.8

7088

5766

95

Compact round

11.7

4.5

0.1

1.6

2.5

3.1

66.8

8239

6446

120

Compact round

13.1

4.5

0.1

1.7

2.5

3.2

70.2

9346

7080

150

Compact round

14.6

4.5

0.1

1.7

3.15

3.4

75.2

11431

8599

185

Compact round

16.3

4.5

0.1

1.8

3.15

3.5

79.2

12953

9461

240

Compact round

18.5

4.5

0.1

1.9

3.15

3.7

84.6

15139

10608

300

Compact round

20.7

4.5

0.1

2.0

3.15

3.8

90.1

17591

11928

400

Compact round

23.8

4.5

0.1

2.1

3.15

4.1

97.6

21504

13953

500

Compact round

26.6

4.5

0.1

2.2

3.15

4.3

105.5

25364

15925

Armoured 3-core cable with XLPE insualtion. Rated voltage 12/20 KV 12.7/22kV

Cable Data

Conductor

 

Insulation thickness (mm)

 

Copper tape screen (approximate) (mm)

 

PVC

bedding thickness (mm)

 

Armored wire diameter (mm)

 

Sheath thickness (mm)

 

Outer diameter (approximate) (mm)

 

Copper core cable weight (kg/km)

 

Aluminum core cable weight (kg/km)

Cross sectional area (mm2)

 

Structure

Outer diameter (mm)

35

Compact round

7.2

5.5

0.1

1.5

2.5

2.9

60.8

5934

5273

50

Compact round

8.4

5.5

0.1

1.6

2.5

3.0

63.8

6706

5763

70

Compact round

10.0

5.5

0.1

1.6

2.5

3.1

67.5

7699

6378

95

Compact round

11.7

5.5

0.1

1.7

2.5

3.3

71.7

8932

7139

120

Compact round

13.1

5.5

0.1

1.8

3.15

3.4

76.4

10907

8641

150

Compact round

14.6

5.5

0.1

1.8

3.15

3.5

79.9

12187

9355

185

Compact round

16.3

5.5

0.1

1.9

3.15

3.6

83.9

13742

10250

240

Compact round

18.5

5.5

0.1

2.0

3.15

3.8

89.3

16001

11471

300

Compact round

20.7

5.5

0.1

2.1

3.15

4.0

95.0

18538

12875

400

Compact round

23.8

5.5

0.1

2.2

3.15

4.2

102.3

22314

14762

500

Compact round

26.6

5.5

0.1

2.3

3.15

4.4

110.2

26392

16953

Armoured 3-core cable with XLPE insualtion. Rated voltage 18/30kV 19/33kV

Cable Data

Conductor

 

Insulation thickness (mm)

 

Copper tape screen (approximate) (mm)

 

PVC

bedding thickness (mm)

 

Armored wire diameter (mm)

 

Sheath thickness (mm)

 

Outer diameter (approximate) (mm)

 

Copper core cable weight (kg/km)

 

Aluminum core cable weight (kg/km)

Cross sectional area (mm2)

 

Structure

Outer diameter (mm)

50

Compact round

8.4

8.0

0.1

1.8

3.15

3.5

77.3

9333

8390

70

Compact round

10.0

8.0

0.1

1.8

3.15

3.6

80.9

10396

9075

95

Compact round

11.7

8.0

0.1

1.9

3.15

3.7

85.0

11723

9930

120

Compact round

13.1

8.0

0.1

2.0

3.15

3.8

88.4

12986

10720

150

Compact round

14.6

8.0

0.1

2.0

3.15

3.9

91.8

14220

11388

185

Compact round

16.3

8.0

0.1

2.1

3.15

4.0

95.9

15887

12395

240

Compact round

18.5

8.0

0.1

2.2

3.15

4.2

101.2

18144

13613

300

Compact round

20.7

8.0

0.1

2.3

3.15

4.4

107.0

20761

15097

400

Compact round

23.8

8.0

0.1

2.4

3.15

4.6

114.3

24824

17273

500

Compact round

26.6

8.0

0.1

2.5

3.15

4.8

122.2

29019

19580


Note: The single-core armored cables are used for the D.C. system only. If used for the A.C. system, the magnetic isolation should be applied to the steel armor wires of non-magnetical materials that should be used.

Medium Voltage Power Cable N2xsy N2xsey Yjv32 Copper Conductor XLPE Insulated Cable 0Medium Voltage Power Cable N2xsy N2xsey Yjv32 Copper Conductor XLPE Insulated Cable 1

N2XSy and N2XSEY: These are cable types used for medium voltage power transmission and distribution. They indicate different variations of XLPE (cross-linked polyethylene) insulated power cables with copper conductors. The "N2XSy" designation typically refers to a single-core cable, while "N2XSEY" usually represents a three-core cable.

YJV32: This is another cable type used for medium voltage power distribution. It stands for a three-core cable with copper conductors, XLPE insulation, and a galvanized steel wire armor.

Copper Conductor: Copper is a highly conductive metal commonly used for power cables due to its low resistance and excellent electrical conductivity. Copper conductors allow efficient transmission of electrical power.

XLPE Insulated: XLPE is a type of insulation material used in power cables. It stands for cross-linked polyethylene, which offers excellent electrical properties, thermal resistance, and mechanical strength for medium voltage cable applications.