logo
Anhui Tongdu International Trade Co., Ltd.
Serviço online

Serviço online

Pessoa de contato
+86 19056002718
Código QR do WeChat
Segue-nos.

cabo distribuidor de corrente médio da tensão

qualidade Cabo MV de Bitola Pesada YJV22 3x150mm² 8.7/15kV Cabo de Energia Blindado XLPE fábrica

Cabo MV de Bitola Pesada YJV22 3x150mm² 8.7/15kV Cabo de Energia Blindado XLPE

Heavy Gauge MV Cable YJV22 3x150mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...

qualidade Mega Industrial Main Cable YJV22 3x120mm2 8.7/15kV Blindado MV XLPE fábrica

Mega Industrial Main Cable YJV22 3x120mm2 8.7/15kV Blindado MV XLPE

Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; U...

qualidade Cabo de Média Tensão de Alta Capacidade YJV22 3x95mm² 8.7/15kV Cabo de Energia Blindado XLPE fábrica

Cabo de Média Tensão de Alta Capacidade YJV22 3x95mm² 8.7/15kV Cabo de Energia Blindado XLPE

High Capacity MV Cable YJV22 3x95mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...

qualidade Cabo de distribuição primário 3 núcleo 70mm2 YJV22 8.7/10kV XLPE blindado fábrica

Cabo de distribuição primário 3 núcleo 70mm2 YJV22 8.7/10kV XLPE blindado

Primary Distribution Cable 3 Core 70mm² YJV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; ...

qualidade Cabo MV Blindado de 3 Núcleos YJV22 3x50mm² 8.7/10kV 8.7/15kV Cabo de Energia XLPE fábrica

Cabo MV Blindado de 3 Núcleos YJV22 3x50mm² 8.7/10kV 8.7/15kV Cabo de Energia XLPE

3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...

Anterior 1 2 3 Próximo