"flat sheathed wires flat electrical sheathed wires 0 5mm to 2 5mm"
Please try a different search term or browse our product categories.
سیم کنترل مسی سبز BV 2.5 میلی متر مربع کابل برق ساختمانی عایق PVC
Green BV 2.5mm² PVC Insulated Copper Control Wire Electrical Building Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or ...
سیم قرمز جامد مسی پی وی سی عایق یک هسته ی مسی
Red BV 2.5mm² PVC Insulated Single Core Copper Live Wire 450/750V Electrical Building Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper ...
?
Photovoltaic Cable 4.0mm2 PV1-F TUV DC Solar Panel Connection Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
3x400mm2 کابل برق ولتاژ متوسط آلومینیوم XLPE کابل Mv زرهی 8.7kV
YJLV22 3x400mm² Aluminum XLPE Armored MV Cable 8.7/15kV Cost Effective Underground Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC outer sheath 22 Steel tape armoured (double steel tape) 3×400 mm² Three cores, each ...
هادی آلومینیومی XLPE کابل 3 هسته 25mm2 YJLV22 8.7/10kV زره دار
Aluminum Conductor XLPE Cable 3 Core 25mm² YJLV22 8.7/10kV Armored Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
کابل فوق سنگین MV YJV22 3x300mm2 8.7/15kV کابل برق زرهی XLPE
Super Heavy MV Cable YJV22 3x300mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
کابل اصلی برق مرکز حمل و نقل YJV22 3x240mm2 8.7/15kV زرهی MV XLPE
Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
کابل مقاوم در برابر آتش 4+1 هسته 120 میلی متر مربع + 1x95 میلی متر مربع BTTRZ کابل زیر ایستگاه آتش
Fire Substation Cable 4+1 Core 120mm²+1x95mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6...