4심 케이블
ZR-YJV 4x70mm² 0.6/1kV 난연 구리 케이블, 건물 전력 분배용 XLPE 절연
ZR-YJV 4×70mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame...
ZR-YJV 4×50mm² 0.6/1kV 난연 구리 케이블, 건물 전력 분배용 XLPE 절연
ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution Technical Datasheet — ZR-YJV 0.6/1 kV 4×50 mm² Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ ...
ZR-YJV 4×35mm2 불 retardant 구리 전력 케이블, 0.6/1kV XLPE 단열 PVC 껍질
ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath Code Mean:ZR-Flame Retardant,YJ-XLPE Insulated,V-PVC Sheath ZR-YJV 4×35 mm² — Cable Data Report 1. Product at a Glance. ZR-YJV 4×35 is a four-core flame-retardant LV cable — four 35 mm² copper conductors, XLPE ...
ZR-YJV 4×25mm2 불 retardant 구리 전력 케이블, 0.6/1kV XLPE 단열 PVC 껍질
ZR-YJV 4×25mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath Code Mean:ZR-Flame Retardant,YJ-XLPE Insulated,V-PVC Sheath ZR-YJV 4×25 mm² — Product Engineering File 1. Product Summary. ZR-YJV 4×25 is a four-core flame-retardant low-voltage cable — four 25 mm² copper conductors...
ZR-YJV 4*16mm² 난연 4심 케이블, 0.6/1kV, XLPE PVC 시스, 실내 전력 배선용
ZR-YJV 4*16mm² Fire Retardant Four Conductor Cable, 0.6/1kV, XLPE PVC Sheath for Indoor Power Wiring Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Sheath ZR-YJV 4×16 mm² — Engineering Data Sheet 1. Product Summary. ZR-YJV 4×16 is a four-core flame-retardant low-voltage cable — four 16 mm² ...
Z
ZR-YJV 4*10mm² Flame Retardant 4 Core Cable, 0.6/1kV, XLPE Insulation PVC Jacket for Construction Power Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Jacket ZR-YJV 4×10 mm² — Product Technical File 1. Product Summary. ZR-YJV 4×10 is a four-core flame-retardant low-voltage cable — four 10 mm² ...
0.6/1kV ZC-YJV 3x70+1x35mm² 구리 XLPE PVC 난연 전력 케이블 (변압기실 저압 인출 회로용)
0.6/1kV ZC-YJV 3x70+1x35mm² Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits Technical Datasheet — ZC-YJV 0.6/1 kV 3×70+1×35 mm² 1. Cable Designation & Meaning Code Meaning ZC Flame retardant, Class C (bundled combustion test per GB/T 18380.3 / GB/T 19666) ...
ZC-YJV 4x50mm² 내화성 XLPE 구리 전력 케이블 (건물 분배용)
ZC-YJV 4x50mm² Class C Flame Retardant XLPE Copper Power Cable for Building Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Category C (GB/T 18380.3) YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 4×50 mm² Four cores, each 50 mm² copper (3 phases + 1 ...