품질 2.5mm2 고체 구리 전도기 땅 고체 토양 불 retardant 공장

2.5mm2 고체 구리 전도기 땅 고체 토양 불 retardant

Yellow Green BV 2.5mm² Ground Earth Wire PVC Insulated Copper Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or stranded)...

품질 백동 건물 전선 PVC 절연 단심 가정용 전기 케이블 공장

백동 건물 전선 PVC 절연 단심 가정용 전기 케이블

BV 2.5mm2 White PVC Insulated Single Core Copper Building Wire 450/750V Household Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain ...

품질 PV1-F 6.0mm² TUV 1500V DC 태양광 케이블 UV 저항 방수 PV 와이어 공장

PV1-F 6.0mm² TUV 1500V DC 태양광 케이블 UV 저항 방수 PV 와이어

PV1-F 6.0mm² TUV 1500V DC Solar Cable UV Resistant Weatherproof PV Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...

품질 ? 공장

?

Photovoltaic Cable 4.0mm2 PV1-F TUV DC Solar Panel Connection Cable Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...

품질 3x300mm2 중전압 전원 케이블 Al XLPE 초중량 알루미늄 케이블 공장

3x300mm2 중전압 전원 케이블 Al XLPE 초중량 알루미늄 케이블

Super Heavy Aluminum Cable YJLV22 3x300mm² 8.7/10kV 8.7/15kV Armored XLPE MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7...

품질 ? 공장

?

Lightweight Aluminum Cable 3 Core 35mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor ​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...

품질 3 코어 장갑 MV 케이블 YJV22 3x50mm2 8.7/10kV 8.7/15kV XLPE 전력 케이블 공장

3 코어 장갑 MV 케이블 YJV22 3x50mm2 8.7/10kV 8.7/15kV XLPE 전력 케이블

3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...

품질 4x185mm2 + 1x150mm2 방화 케이블 0.6KV 1KV 광물 단열 구리 케이블 공장

4x185mm2 + 1x150mm2 방화 케이블 0.6KV 1KV 광물 단열 구리 케이블

Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...