"standard color coding flexible control wire cable"
Please try a different search term or browse our product categories.
전선관 설치용 블랙 BV 2.5mm2 단선 구리 코어 Cu PVC 와이어
Black BV 2.5mm² Solid Copper Conductor PVC Wire for Conduit Installation Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or ...
백동 건물 전선 PVC 절연 단심 가정용 전기 케이블
BV 2.5mm2 White PVC Insulated Single Core Copper Building Wire 450/750V Household Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain ...
콘크리트 된 구리 태양 전지 케이블 태양 전지 패널 자외선 저항 PV 와이어
Solar Panel Cable H1Z2Z2-K 4.0mm² TUV 1500V DC UV Resistant PV Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen...
알루미늄 XLPE 케이블 YJLV22 3x70mm2 8.7/15kV 장갑 MV 전원 케이블
Aluminum XLPE Cable YJLV22 3x70mm² 8.7/15kV Armored MV Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
자이언트 MV 케이블 YJV22 3x400mm² 8.7/15kV 아머드 XLPE 전력 케이블
Giant MV Cable YJV22 3x400mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; Uₘ = ...
?
Heavy Gauge MV Cable YJV22 3x150mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
고 용량 MV 케이블 YJV22 3x95mm2 8.7/15kV 장갑 XLPE 전력 케이블
High Capacity MV Cable YJV22 3x95mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
BTLY 방화용 케이블 4x35mm2 + 1x16mm2 알루미늄 껍질 케이블 비상용
NG-A BTLY 4x35+1x16mm2 Mineral Insulated Fire Resistant Aluminum Sheath Cable for Emergency Cable Designation & Meaning Code Meaning NG-A New Generation A-class fire-resistant (Chinese designation) (BTLY) Building wire, Thin copper conductor, Lightweight Y— alternative naming convention indicating: ...