logo
Anhui Tongdu International Trade Co., Ltd.
온라인 서비스

온라인 서비스

담당자
+86 19056002718
위챗 QR 코드
따라와
No Products Found Matching Your Search Criteria:

"pvc single core electrical cable"

Please try a different search term or browse our product categories.

Recommend Other Products
품질 H1Z2Z2-K 4.0mm2 태양광 케이블 TUV 1500V XLPE 구리 케이블 공장

H1Z2Z2-K 4.0mm2 태양광 케이블 TUV 1500V XLPE 구리 케이블

H1Z2Z2-K 4.0mm² TUV 1500V DC Solar Cable UV Resistant Halogen Free XLPE Copper Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z ...

품질 P 공장

P

PV1-F 4.0mm² TUV Certified Solar Cable 1500V DC UV Resistant Photovoltaic Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper ...

품질 DC (PV) 태양 전지 케이블 H1Z2Z2-K 4.0 mm2 단일 코어 틴 구리 XLPE/XLPO 단열 공장

DC (PV) 태양 전지 케이블 H1Z2Z2-K 4.0 mm2 단일 코어 틴 구리 XLPE/XLPO 단열

DC (PV) Solar Cable H1Z2Z2-K 4.0 mm² Single Core Tinned Copper XLPE/XLPO Insulated H1Z2Z2-K 1×4.0 mm² Photovoltaic (PV) DC Solar Cable. H ​ = Harmonised EU designation · 1Z2Z2 ​ = halogen-free (HFFR) insulation + halogen-free (HFFR) sheath, both cross-linked · K ​ = flexible Class 5 conductor · 1×4...

품질 ? 공장

?

Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...

품질 초중량 MV 케이블 YJV22 3x185mm2 8.7/15kV 장갑 XLPE 전력 케이블 공장

초중량 MV 케이블 YJV22 3x185mm2 8.7/15kV 장갑 XLPE 전력 케이블

Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...

품질 메가 산업 메인 케이블 YJV22 3x120mm2 8.7/15kV 장갑 MV XLPE 공장

메가 산업 메인 케이블 YJV22 3x120mm2 8.7/15kV 장갑 MV XLPE

Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; U...

품질 3 코어 장갑 MV 케이블 YJV22 3x50mm2 8.7/10kV 8.7/15kV XLPE 전력 케이블 공장

3 코어 장갑 MV 케이블 YJV22 3x50mm2 8.7/10kV 8.7/15kV XLPE 전력 케이블

3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...

품질 4x185mm2 + 1x150mm2 방화 케이블 0.6KV 1KV 광물 단열 구리 케이블 공장

4x185mm2 + 1x150mm2 방화 케이블 0.6KV 1KV 광물 단열 구리 케이블

Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...