"pvc or pe low voltage power cord"
Please try a different search term or browse our product categories.
RVV 5x4.0mm2 5 코어 플렉시블 케이블 PVC 멀티 서킷 연선 유연 구리 케이블
RVV 5x4.0mm2 5 Core Flexible PVC Stranded Copper Cable 300/500V Multi Circuit Cable Designation & Meaning Code Meaning R Flexible conductor (Class 5 fine-stranded copper) V PVC (polyvinyl chloride) insulation V PVC (polyvinyl chloride) outer sheath 5×4.0 mm² Five cores, each 4.0 mm² flexible copper ...
태양광 패널 연결 케이블 PV1-F 4.0mm² TUV 1500V DC 방수 PV 와이어
Solar Panel Connection Cable PV1-F 4.0mm² TUV 1500V DC Weatherproof PV Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor...
P
PV1-F 4.0mm² TUV Certified Solar Cable 1500V DC UV Resistant Photovoltaic Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper ...
3 코어 중압 전력 케이블 중량 185mm2 장갑 XLPE 케이블
Heavy Duty Aluminum Cable 3 Core 185mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
?
Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
초중량 MV 케이블 YJV22 3x185mm2 8.7/15kV 장갑 XLPE 전력 케이블
Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
4x185mm2 + 1x150mm2 방화 케이블 0.6KV 1KV 광물 단열 구리 케이블
Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...
대형 내화 전선 4x95mm2+1x70mm2 미네랄 절연 난방 케이블
Large Fire Cable BTTRZ 4x95mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...