"4 core flexible cable 4x0 75mm2"
Please try a different search term or browse our product categories.
緑銅制御線 BV 2.5mm2 PVC絶縁電気建築ケーブル
Green BV 2.5mm² PVC Insulated Copper Control Wire Electrical Building Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or ...
白銅ビルワイヤー PVC絶縁単心家庭用電線
BV 2.5mm2 White PVC Insulated Single Core Copper Building Wire 450/750V Household Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain ...
TUV 1kV ソーラーケーブル H1Z2Z2-K 4mm2 PVケーブル
1500V DC Solar Wire H1Z2Z2-K 4.0mm² TUV XLPE Photovoltaic Cable Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen-free ...
PV1-F 6.0mm2 TUV 1500V DC 太陽電池ケーブル UV耐性 防天光線
PV1-F 6.0mm² TUV 1500V DC Solar Cable UV Resistant Weatherproof PV Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...
3x120mm2 中圧電力ケーブル 8.7kV 15kV アルミニウム MCケーブル
Industrial Main Aluminum Cable YJLV22 3x120mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated ...
ジャイアントMVケーブルYJV22 3x400mm² 8.7/15kV アーマードXLPEパワーケーブル
Giant MV Cable YJV22 3x400mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; Uₘ = ...
メガ産業主ケーブル YJV22 3x120mm2 8.7/15kV 装甲MV XLPE
Mega Industrial Main Cable YJV22 3x120mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; U...
大型耐火電線 4x95mm2+1x70mm2 ミネラル絶縁加熱ケーブル
Large Fire Cable BTTRZ 4x95mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...